Hi,
you are simply running out of IPC Semaphores. Increase the number of IPC semaphores 
supplied by your OS
(i.e. by reconfiguring your OS kernel).
CU
jrg

> -----Original Message-----
> From: "Engbert, Christian (GGRZ M�nster)"
> [mailto:[EMAIL PROTECTED]]
> Sent: Freitag, 14. Februar 2003 11:51
> To: [EMAIL PROTECTED]
> Subject: Kernel Died
> 
> 
> Hi,
> 
> I have a problem wie my SApdb(7.3.0.29). When I try to start 
> an craetet DB I
> become always the errormessage:
> 
>  -24994 runtime environment error [db_cold -f] Kernel Died 
> before reaching COLD
> stat. 
> 
> The loged error message in the knldiag.err is:
>  1 ERR 11277 IPC      create_sem: semget error, No space left 
> on device 
> 
> Can anyone tell me how i can fix it or what i have made wrong?
> 
> MFG
> 
> Christian
> Engbert
> 
> --
> Christian Engbert
> GGRZ M�nster
> Von-Vincke-Str. 23-25
> 48143 M�nster
> 
> Fon     0251 68698 204
> Fax     0251 68698 500
> Mail     mailto:[EMAIL PROTECTED]
> _______________________________________________
> sapdb.general mailing list
> [EMAIL PROTECTED]
> http://listserv.sap.com/mailman/listinfo/sapdb.general
> 