A couple of possibilities to consider: - use a private network (or perhaps even just an Ethernet crossover cable) between the systems to ssh into the unreachable system to perform an ifdown. - have the surviving system access an external console / pdu to remove power from the unreachable system (stonith - shoot the other node in the head).
-Keith. On May 1, 2014, at 11:31 AM, CS_DBA <[email protected]> wrote: > Hi All; > > we have a failover tool (for a database) that pings te master and if it's not > responding runs ifdown over ssh to bring an ip alias down, then runs ifup of > the alias on the standby node. > > A possible issue would be if the master was not reachable, thus the ifdown > fails and once the master becomes available again then we have 2 nodes with > the ip alias and we risk a split brain issue > > Is there a way to disable any traffic from getting to the old master via > commands we can run outside of the master server? > > Thanks in advance