URL: <https://savannah.gnu.org/bugs/?68393>
Summary: Serial mode parity/stop-bit options missing in v5
Group: GNU Screen
Submitter: pdey
Submitted: Fri 22 May 2026 09:12:07 PM UTC
Category: Program Logic
Severity: 3 - Normal
Priority: 5 - Normal
Status: None
Privacy: Public
Assigned to: None
Open/Closed: Open
Discussion Lock: Unlocked
Release: 5.0.0
Fixed Release: None
Planned Release: None
Work Required: None
_______________________________________________________
Follow-up Comments:
-------------------------------------------------------
Date: Fri 22 May 2026 09:12:07 PM UTC By: Peter Dey <pdey>
Parity and stop-bit options that were available in 4.9.x were added to the
screen-v4 branch after screen-v5 diverged:
https://cgit.git.savannah.gnu.org/cgit/screen.git/commit/?id=8b386d8
"Support stop/parity bits on serial port"
Specifically, these were lost:
- cstopb / -cstopb
- parenb / -parenb
- parodd / -parodd
Serial setups that need e.g. 7E1/8E1 (or explicit stop-bit control) cannot be
configured via screen options anymore.