On Tue, Jan 17, 2017 at 09:46:10AM +0100, Paolo Bonzini wrote: > On 13/01/2017 10:48, Ladi Prosek wrote: > > If the HBA supports 64-bit addressing, the registers may contain > > non-zero values, for example after reboot as a leftover from the > > OS driving the adapter. > > > > Signed-off-by: Ladi Prosek <[email protected]> > > --- > > src/hw/ahci.c | 5 +++++ > > 1 file changed, 5 insertions(+) > > > > diff --git a/src/hw/ahci.c b/src/hw/ahci.c > > index 261a7d2..2eee192 100644 > > --- a/src/hw/ahci.c > > +++ b/src/hw/ahci.c > > @@ -361,6 +361,11 @@ ahci_port_alloc(struct ahci_ctrl_s *ctrl, u32 pnr) > > > > ahci_port_writel(ctrl, pnr, PORT_LST_ADDR, (u32)port->list); > > ahci_port_writel(ctrl, pnr, PORT_FIS_ADDR, (u32)port->fis); > > + if (ctrl->caps & HOST_CAP_64) { > > + ahci_port_writel(ctrl, pnr, PORT_LST_ADDR_HI, 0); > > + ahci_port_writel(ctrl, pnr, PORT_FIS_ADDR_HI, 0); > > + } > > + > > return port; > > } > > Weird as it may seem, HBA reset doesn't clear the address fields > according to the spec. > > Reviewed-by: Paolo Bonzini <[email protected]>
Thanks. I committed this change. -Kevin _______________________________________________ SeaBIOS mailing list [email protected] https://www.coreboot.org/mailman/listinfo/seabios