https://issues.jboss.org/browse/SOLDER-63?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Dan Allen updated SOLDER-63:
----------------------------

    Workaround Description: Put the Logger injection on a CDI bean and delegate 
to it.
                Workaround: [Workaround Exists]


> Fallback to member's declaring type if bean is unreachable at Logger 
> injection point
> ------------------------------------------------------------------------------------
>
>                 Key: SOLDER-63
>                 URL: https://issues.jboss.org/browse/SOLDER-63
>             Project: Seam Solder
>          Issue Type: Bug
>          Components: Logging
>    Affects Versions: 3.0.0.Beta1
>            Reporter: Dan Allen
>            Assignee: Dan Allen
>             Fix For: 3.0.0.Beta2
>
>
> There are situations when the InjectionPoint#getBean() is null. [1] In this 
> case, the producer for Logger should retrieve the type using 
> InjectionPoint.getMember().getDeclaringClass().
> One case when this happens is when non-contextual injection is being used. We 
> should allow for this.
> [1] InjectionPoint#getBean() JavaDoc states: "If the injection point does not 
> belong to a bean, return a null value."

-- 
This message is automatically generated by JIRA.
-