Jim,
If you had the expected output at U12 pin 8, but less than expected at
U11 pin 1, then there is a problem between those two points. Look at
the schematic in conjunction with these troubleshooting steps to find
what lies between the two points - in this case, look in the lower right
quadr
I am using the procedures in a Rev C manual, Appendix E, Page 10-11 to
troubleshoot a "dead receiver" problem. All Rework Eliminators are
installed. Signal tracing through the PLL/VCO and Low-Pass Filter,
Bandpass Filter, and T-R Switch produced expected measurements. In the
Mixer, I.F. Amp, and Xt
lator that might drive the AGC. The filter
chops this down. 2) A simple matter of drive level 3) To reduce AGC Attack
delay.
73.
Geoff,
GM4ESD
- Original Message -
From: "Stewart Baker" <[EMAIL PROTECTED]>
To: "Elecraft Reflector"
Sent: Saturday, March 05, 2005 11
Anyone any experience of, or thoughts about adding another 3 crystals to the K2
2nd crystal filter ?
73
Stewart G3RXQ
___
Elecraft mailing list
Post to: Elecraft@mailman.qth.net
You must be a subscriber to post to the list.
Subscriber Info (Addr. Chang
4 matches
Mail list logo