Find
can
warp you to a new sheet
if the string matches a component that isn't on the current sheet
. If that sheet hasn't
yet
been shown
during the session
, the dangling ends
have
not
been
calculated
, so we force it here.
Best-
Seth
On Dec 10, 2017 5:44 PM, "Wayne Stambaugh
Seth,
Why is it necessary to test for dangling end on a find? Find only
searches for string matches so I'm having a hard time understanding why
the dangling ends need to be cleaned up.
Cheers,
Wayne
On 12/09/2017 11:45 PM, Seth Hillbrand wrote:
> This patch fixes https://bugs.launchpad.net/ki
Hi Wayne-
Nope. It was part of the larger junction management patch set that was
already merged.
Best-
Seth
On Dec 10, 2017 3:33 PM, "Wayne Stambaugh" wrote:
> Seth,
>
> Does this patch still needs to be applied? I'm getting buried with the
> patch submissions.
>
> Thanks,
>
> Wayne
>
> On 0
Seth,
Does this patch still needs to be applied? I'm getting buried with the
patch submissions.
Thanks,
Wayne
On 09/27/2017 07:57 PM, Seth Hillbrand wrote:
> Hi Jon-
>
> Thanks for catching that. The delete node/delete connection follow a
> different path to deletion, so I missed them initia
Jon,
I merged your patch into the master branch.
Thanks,
Wayne
On 12/09/2017 01:08 PM, Jon Evans wrote:
> Fixes: https://bugs.launchpad.net/kicad/+bug/1737315
>
> -Jon
>
>
> ___
> Mailing list: https://launchpad.net/~kicad-developers
> Post to
Dear Kicad developers,
The "operator BOX2I() const" of EDA_RECT produced wrong boxes, usually
much to big. It passed its end-position as second argument to the
constructor of BOX2I. However, BOX2I expects its size as second
argument.
This caused a dramatic performance penalty in some
cases. Took
Dear Kicad developers,
The polygon drawing routing in the OpenGL-GAL did
not plot polygons which are "closed", i.e. have a segment
from their last point to their first point, correctly.
That segment was omitted.
The patch attached fixes this bug.
Cheers,
Andreas
>From 837eecbdae9b778525b12fdde19
Jon-
Thanks for catching this discrepancy. I had written the logic such that
busses connect to other busses by a bus-to-bus entry. But clearly, that is
historically not accurate and there needs to be a junction.
-S
On Sun, Dec 10, 2017 at 8:09 AM, Jon Evans wrote:
> Hi all,
>
> As I am worki
Just pushed this patch - thank you!
On Sun, Dec 10, 2017 at 06:35:44PM +, Jon Evans wrote:
> Hi all,
>
> Quick fix for an arc drawing path that still had some wrong logic in it.
>
> -Jon
___
Mailing list: https://launchpad.net/~kicad-developers
P
Hi all,
Quick fix for an arc drawing path that still had some wrong logic in it.
-Jon
From 318991f7202e42af73367be7f3ba4bf872efd4ce Mon Sep 17 00:00:00 2001
From: Jon Evans
Date: Sun, 10 Dec 2017 13:35:00 -0500
Subject: [PATCH] Remove outdated check on endAngle to fix arc draw direction
Fixes:
Hi all,
As I am working on bus features I have dived into all the ways you can use
buses (that I haven't always known about myself).
One thing I noticed was an example given on the docs:
http://docs.kicad-pcb.org/stable/en/eeschema.html#wires-buses-labels-power-ports
Under "Global connections be
11 matches
Mail list logo