On Wed, Nov 07, 2018 at 06:30:13PM +0200, Laurent Pinchart wrote:
> Hi Simon,
>
> On Tuesday, 6 November 2018 16:00:35 EET Simon Horman wrote:
> > On Mon, Nov 05, 2018 at 02:12:43PM +0100, Jacopo Mondi wrote:
> > > The VIN driver bindings dictates fixed numbering for VIN endpoints
> > > connected
Hi Simon,
On Tuesday, 6 November 2018 16:00:35 EET Simon Horman wrote:
> On Mon, Nov 05, 2018 at 02:12:43PM +0100, Jacopo Mondi wrote:
> > The VIN driver bindings dictates fixed numbering for VIN endpoints
> > connected to CSI-2 endpoints, even when a single endpoint exists.
> >
> > Without prope
On Mon, Nov 05, 2018 at 02:12:43PM +0100, Jacopo Mondi wrote:
> The VIN driver bindings dictates fixed numbering for VIN endpoints connected
> to CSI-2 endpoints, even when a single endpoint exists.
>
> Without proper endpoint numbering the VIN driver fails to probe.
>
> Based on a patch in BSP f
The VIN driver bindings dictates fixed numbering for VIN endpoints connected
to CSI-2 endpoints, even when a single endpoint exists.
Without proper endpoint numbering the VIN driver fails to probe.
Based on a patch in BSP from Koji Matsuoka
Fixes: ec70407ae7d7 ("arm64: dts: renesas: r8a77990: A