Am Montag, den 19.10.2009, 18:35 -0400 schrieb Paul Alfille:
I love a patch!
Does it correct your hardware problem?
definitely it improves the situation !
i am now running with 1,8,3 for slewrate, w1l, dso set in my pathon app
as i mentioned some postings ago.
i am able to communicate with
Hi paul,
i was off-duty for the past few days, checked your change today, but no
luck at all ...
according to debug message from USB_Control_Msg the values now get
transferred after changing them - i see this as a huge part of the patch
- but the values set are always the start up (==default)
Dear Paul, dear list,
i finally came up with a patch (against current HEAD) which doesn't
overwrite the changed settings with the default ones ...
please review and merge into HEAD - as i am not 100% sure if the call to
DS9490_SetFlexParameters () is in the correct place ... ;)
thanks,
marcus.
I love a patch!
Does it correct your hardware problem?
Paul
On Mon, Oct 19, 2009 at 2:53 PM, Marcus Priesch mar...@priesch.priv.atwrote:
Dear Paul, dear list,
i finally came up with a patch (against current HEAD) which doesn't
overwrite the changed settings with the default ones ...
From my experience, I'm successfully operating three ds18b20, two ds2413,
one ds2406 at the far end of my garden on a 120 meters branch using CAT5
cable.
However, parastatic devices where quite unreliable until I added a line
termination as shown in AN132, pg 5, Figure 5.
Dear pascal, dear paul,
thanks for your answers, after another day of measuring and fiddling
around i proceeded some steps further:
adding the add-on circuit for long lines i managed to get
communication with 4 sensors, thats a total of 75 meters with my current
configuration - i managed to
Thanks for the answer !
paul, is it possible to modify these settings from within python ?!?!
if not, then i'll have to rewrite my 1wire stuff ...
regards,
marcus.
Am Dienstag, den 13.10.2009, 14:03 -0400 schrieb Paul Alfille:
I'll look a little closer, but it appears we're overwriting those
Yup,
i found it already ...
import ow
ow.init (u)
ow.owfs_get (/bus.0/interface/settings/usb/datasampleoffset)
' 7'
ow.owfs_put (/bus.0/interface/settings/usb/datasampleoffset,8)
0
ow.owfs_get (/bus.0/interface/settings/usb/datasampleoffset)
' 8'
that should do it ;)
The CVS repository has the corrections. They will b in the next release --
this weekend.
Paul Alfille
On Tue, Oct 13, 2009 at 3:55 PM, Marcus Priesch mar...@priesch.priv.atwrote:
Yup,
i found it already ...
import ow
ow.init (u)
ow.owfs_get
Dear owfs-developers ...
thanks for the great work, i am using owfs for quite some years for my
heating controller and it works perfectly !!!
although currently i have some difficulties ... which i was not able to
get rid of and thats the reason why i am posting here ...
in my current project
Thank you, Marcus, for your kind words.
In truth, I've never had a reason to alter the slew rate, and so can't claim
that code path is well tested. This may be a good opportunity.
I presume you are choosing a slewrate of 0 to 7.
From module/owlib/src/c/ow_interface.c:
/*
* Value is between 0
11 matches