Hello!
pacemaker pingd with ms drbd = double masters short time when
disconnected networks.
My crm config:
node 168885811: pp-pacemaker1.heliosoft.ru
node 168885812: pp-pacemaker2.heliosoft.ru
primitive drbd1 ocf:linbit:drbd \
params drbd_resource=drbd1 \
op monitor interval=60s \
On 20/05/16 17:04 +0100, Adam Spiers wrote:
> Klaus Wenninger wrote:
>> On 05/20/2016 08:39 AM, Ulrich Windl wrote:
>>> I think RAs should not rely on "stop" being called multiple times
>>> for a resource to be stopped.
>
> Well, this would be a major architectural change. Currently if
> stop fa