Hi!
An update:
The fix was to delete the nodes and re-create them. CRM shell was happy then,
displaying the node like this:
---
node h04 \
utilization utl_cpu=200 utl_ram=1200 attributes standby=off
---
But when committing the config I got warnings in syslog like this:
pengine[25263]:
Hi Ulrich,
thank you for your answer,
what about which limits do you talk?
The pacemaker software runs by root user, so limits should be increased for
root.
There is output from one of my server:
-bash-4.1# id
uid=0(root) gid=0(root) groups=0(root)
-bash-4.1# ulimit -a
core file size
On 12/13/2015 06:56 PM, Ferenc Wagner wrote:
> Ken Gaillot writes:
>
>> On 12/11/2015 10:07 AM, Ferenc Wagner wrote:
>>
>>> [...] the "Legal Notice"
>>> section of the generated Publican documentation (for example
>>> Pacemaker_Explained/desktop/en-US/index.html) says that the material may
>>> on
The source code for the latest Pacemaker release candidate is available
at
https://github.com/ClusterLabs/pacemaker/releases/tag/Pacemaker-1.1.14-rc3
This is a bugfix release:
* When deleting an attribute from a fence device, the entire device
would sometimes be deleted.
* 0f9a4eb0 introduced a