Re: [AFMUG] Mid-Span multi-voltage powerinjector withredundant power..

2016-03-01 Thread Peter Kranz
Do you want surge suppressors on each circuit? I personally do not require 
surge suppressors, I’ve always assumed the surge suppression should be outside 
the shack, not in the rack.

 

Do you want individually replaceable circuits or all on one board? Assuming the 
board is designed not to grenade under reasonable failure scenarios it can be 
all one board

 

How many ports? 24 ports.

 



Re: [AFMUG] Mid-Span multi-voltage powerinjector withredundant power..

2016-03-01 Thread Chuck McCown
Do you want surge suppressors on each circuit?
Do you want individually replaceable circuits or all on one board?
How many ports?

From: Peter Kranz 
Sent: Tuesday, March 01, 2016 11:54 AM
To: af@afmug.com 
Subject: Re: [AFMUG] Mid-Span multi-voltage powerinjector withredundant power..

Here is my ideal solution:

 

-  Solid state fusing on each radio, so that I get cable or radio 
damage it doesn’t take down my entire +24V power rail, it just shuts down that 
port

-  The ability to enable/disable the power rail remotely to each port 
for hard resets

-  A power rail that accepts two power supplies and will handle the 
failure of either device without dropping the APs

-  19” rack mountable

-  If device requires fans or internal power supplies, they should be 
replaceable without having to take the unit out of service.

 

Nice to have (but not a deal killer)

 

-  Multi-voltage capable... 48V UPOE for Siklus, 24V for UBNT and 
Cambium 

 

What I don’t want

 

-  A built in switch, I already have fancy ass switches, why do I need 
another switch in the way, probably with crappy features and poor buffers.

 

Peter Kranz
www.UnwiredLtd.com
Desk: 510-868-1614 x100
Mobile: 510-207-
pkr...@unwiredltd.com

 

From: Af [mailto:af-boun...@afmug.com] On Behalf Of Chuck McCown
Sent: Monday, February 29, 2016 3:27 PM
To: af@afmug.com
Subject: Re: [AFMUG] Mid-Span multi-voltage power injector withredundant power..

 

The power bus can be done.  But price will jump quite a bit.  I have worked up 
a design for this but always backed off due to the cost.  One of the problems 
is that there is a connector I need that cannot be put on the circuit board by 
machine.  Lots of hand work.  So if I build it will anyone come?

 

From: Peter Kranz 

Sent: Monday, February 29, 2016 3:55 PM

To: af@afmug.com 

Subject: Re: [AFMUG] Mid-Span multi-voltage power injector withredundant power..

 

I like the idea, but no solid state fusing, no power buss, tons of wiring, it’s 
a mess to deploy this when you have over 20 APs on a single tower.. 

 

Peter Kranz
www.UnwiredLtd.com
Desk: 510-868-1614 x100
Mobile: 510-207-
pkr...@unwiredltd.com

 

From: Af [mailto:af-boun...@afmug.com] On Behalf Of Sean Heskett
Sent: Monday, February 29, 2016 10:35 AM
To: af@afmug.com
Subject: Re: [AFMUG] Mid-Span multi-voltage power injector with redundant 
power..

 

 

 

GigE-POE- APC 
http://www.mccowntech.com/rack-mount-gige-poe-apc-surge-suppressor-power-inserter-protector/

 

You can load 24 of them in a 1U rack

 

-Sean 

On Monday, February 29, 2016, Peter Kranz <pkr...@unwiredltd.com> wrote:

  Curious if anyone has recommendations on a mid-span power injector that 
supports multiple voltages and provides redundant power, ideally hot-swappable. 
I don’t really want a switch like the netonix boxes, I’d rather just have a 
mid-span device. 

   

  Peter Kranz
  www.UnwiredLtd.com
  Desk: 510-868-1614 x100
  Mobile: 510-207-