Re: [AFMUG] Power a SLAVE PTP230 BH from a syncinjector

2017-12-01 Thread Matt
Have done it all the time and never even turned sync off.  We have
pulled almost all PTP230's from network and updated too PTP450's
though.  Make sure your syncinjector is powered on 24 volt though.



On Fri, Dec 1, 2017 at 8:48 AM, Wireless Administrator  wrote:
> I have an application where it would be more convenient to power a SLAVE
> PTP230 BH from a syncinjector than to use a separate power supply.  I don’t
> see where this would be a problem and I suppose I could turn sync off on the
> port using SiteMonitor if needed.  Can anyone validate this as an acceptable
> practice.
>
>
>
> Steve B.


Re: [AFMUG] Power a SLAVE PTP230 BH from a syncinjector

2017-12-01 Thread Jerry Head

We have done it.

On 12/1/2017 8:48 AM, Wireless Administrator wrote:


I have an application where it would be more convenient to power a 
*_SLAVE _*PTP230 BH from a syncinjector than to use a separate power 
supply.� I don�t see where this would be a problem and I suppose I 
could turn sync off on the port using SiteMonitor if needed.� Can 
anyone validate this as an acceptable practice.


Steve B.