Re: amanda fails

2021-10-19 Thread Charles Curley
On Tue, 19 Oct 2021 10:19:28 +0200
"Stefan G. Weichinger"  wrote:

> Switching the parameter "taperscan" from "lexical" to "traditional" 
> works around that now.

I don't have taperscan in either of my configurations, so I guess I'm
running on the default. The lack probably comes from more than a decade
of copying in old configurations every time I install.

-- 
Does anybody read signatures any more?

https://charlescurley.com
https://charlescurley.com/blog/


Re: amanda fails

2021-10-19 Thread Stefan G. Weichinger

Am 18.10.21 um 18:00 schrieb Charles Curley:

On Mon, 18 Oct 2021 14:38:46 +0200
"Stefan G. Weichinger"  wrote:


Anyone seeing this as well?


FAILURE DUMP SUMMARY:
taper: FATAL Can't use an undefined value as an ARRAY reference at
/usr/lib/x86_64-linux-gnu/amanda/perl/Amanda/ScanInventory.pm line
343.

This on a debian-10.10 server


Nope. Never seen it. I am using VTAPEs.


Updated to 10.11, no change.

Amanda does not dump or flush to tapes because of that error.

I am not aware of any changes to the amanda config lately.

Switching the parameter "taperscan" from "lexical" to "traditional" 
works around that now.


Although I remember that Jean-Louis told me back then to use "lexical" 
to make things work with my setup of aggregating multiple chg-disk changers.