Re: [ARTIQ] getting the 3rd Urukul to work

2019-01-31 Thread Nico Pulido via ARTIQ


Hi David, and thanks for your reply.

Quoting David Nadlinger:
Is the third Urukul correctly defined in the gateware build? I've  
seen hangs like this when there wasn't actually an SPI core at the  
specified RTIO address.


That sounds very reasonable, I will further investigate in that direction.

Cheers,
Nico


___
ARTIQ mailing list
https://ssl.serverraum.org/lists/listinfo/artiq


Re: [ARTIQ] getting the 3rd Urukul to work

2019-01-31 Thread David Nadlinger via ARTIQ

Hi Nico,

On 31 Jan 2019, at 15:42, Nico Pulido via ARTIQ wrote:
If we try to use the third one, the experiment just keeps running and 
the Urukul does not respond.


Is the third Urukul correctly defined in the gateware build? I've seen 
hangs like this when there wasn't actually an SPI core at the specified 
RTIO address.


Best,
David



___
ARTIQ mailing list
https://ssl.serverraum.org/lists/listinfo/artiq


Re: [ARTIQ] Frame grabber

2019-01-31 Thread Sébastien Bourdeauducq via ARTIQ

Hi,

The Grabber card is not compatible with CoaXpress.

Using CoaXpress with Kasli should be possible via its SATA connector, 
but requires nontrivial development in hardware and gateware.


Sébastien


On 2/1/19 12:02 AM, Harry Parke via ARTIQ wrote:

Dear ARTIQ list members,


Does anybody know if the Frame Grabber Interface is only compatible with 
Camera Link or whether anything can be done so that it works with other 
fast data transfer interfaces such as CoaXpress?



Many thanks,

Harry Parke

___
ARTIQ mailing list
https://ssl.serverraum.org/lists/listinfo/artiq


[ARTIQ] Frame grabber

2019-01-31 Thread Harry Parke via ARTIQ
Dear ARTIQ list members,


Does anybody know if the Frame Grabber Interface is only compatible with Camera 
Link or whether anything can be done so that it works with other fast data 
transfer interfaces such as CoaXpress?


Many thanks,

Harry Parke
___
ARTIQ mailing list
https://ssl.serverraum.org/lists/listinfo/artiq


[ARTIQ] getting the 3rd Urukul to work

2019-01-31 Thread Nico Pulido via ARTIQ

Dear all,

I would like to kindly ask for your help with a little problem that we  
are encountering at the IQO in Hannover. We are playing around with a  
crate that has a Kasli SN 14. Everything works fine but for one thing:


We have 3 Urukuls and we cannot get the third one to work (the other  
two are working fine).


If we try to use the third one, the experiment just keeps running and  
the Urukul does not respond.


Here is our device_db.py:
https://pastebin.com/fq1eQscC

At first we thought it might be a problem with the channels. But if we  
rearrange them, nothing changes: it is the third card the one the  
gives trouble always.


If someone has an idea of what could possibly be the problem it would  
be awesome.


Cheers,
Nico


___
ARTIQ mailing list
https://ssl.serverraum.org/lists/listinfo/artiq