Re: [asterisk-users] PRI got event: HDLC Abort (6) on Primary D-channel of span 1 (fwd)
i had the same Problem, but i don't know why, i spitted the second card in a second Asterisk Box, and its wokring, with 2 TE405P in one Server its not working. If you solved the Problem, please let me know. Thanks Nico On Thu, 20 Jul 2006, asterisk wrote: Hi all, We have two server with *. With 2-2 PRI card (sangoma , digium TE110P, digium TE100P).server 1: - asterisk: SVN-branch-1.2-r36998M - span 1 Digium Wildcard TE110P T1/E1 - span 2 Digium Wildcard TE110P T1/E1 zap show status Description Alarms IRQbpviol CRC4 Digium Wildcard TE110P T1/E1 Card 0 OK 0 0 0 Digium Wildcard TE110P T1/E1 Card 1 OK 0 0 0 server 2: - asterisk: SVN-branch-1.2-r37402M - span 0 Digium Wildcard E100P E1/PRA - span 1 wanpipe1 (Sangoma) zap show status Description Alarms IRQbpviol CRC4 Digium Wildcard E100P E1/PRA Card 0 OK 0 0 0 wanpipe1 card 0 OK 0 0 0 server 1 connecting to server 2 with two E1 cross cable. server 1 drops the next messages: Jul 20 10:23:24 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:23:27 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:23:27 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:23:28 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:24:29 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 1 Jul 20 10:24:29 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 1 Jul 20 10:24:29 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 1 Jul 20 10:25:04 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:25:04 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:25:04 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:26:26 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:26:26 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 1 Jul 20 10:26:28 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Bad FCS (8) on Primary D-channel of span 1 Jul 20 10:26:29 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:26:29 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:26:59 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:27:00 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:27:19 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:27:19 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:27:26 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jul 20 10:27:26 NOTICE[11074]: chan_zap.c:8207 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 server 2 dont drop nothing zaptel.conf on server 1: loadzone=hu defaultzone=hu # TE110P PRI interface [wcte11xp kernel module] span=1,1,0,ccs,hdb3,crc4 bchan=1-15 dchan=16 bchan=17-31 span=2,2,0,ccs,hdb3,crc4 bchan=32-46 dchan=47 bchan=48-62 zaptel.conf on server 2: loadzone=hu defaultzone=hu # E100P PRI interface [wct1xxp kernel module] span=1,1,0,ccs,hdb3,crc4 bchan=1-15 dchan=16 bchan=17-31 # Sangoma A101u PRI span=2,0,0,ccs,hdb3,crc4 bchan=32-46 dchan=47 bchan=48-62 can you give me some help? How can i fix this problem? Thx Kind regards, Szolke ___ --Bandwidth and Colocation provided by Easynews.com -- asterisk-users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users ___ --Bandwidth and Colocation provided by Easynews.com -- asterisk-users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users
Re: [Asterisk-Users] PRI got event: HDLC Abort (6) on Primary D-channel of span 1
See inline comments: Peter Svensson wrote: What span is your clock source? A TE405P card can only operate in one clock domain at a time. I.e. the same clock will be used on all of them. Not correct, I actual have span 1 connected to my telco and span 2 connected to a Norstar PBX. See diagram. Telco - Asterisk - Norstar PBX If both providers are connected to the same TE405P card you will most likely have a problem with one of them unless they in turn have their clocks locked to a common source. For this, span 1 is CPE and span 2 is network. Two differently clocked sources wil manifest themselves as the occasional bit slip. I am not sure if a bit slip can cause the problems on the D channel you are seeing. Before I when into production, I created a stress test using the TE405P and a Dialogic D/MV960A 4T1. Between both cards, I had different clocking sources on each port; not a problem. I was able to generate millions of calls between the two with out any problems, Peter Anyways, the source of my problem was infact the telco, and 6 hours after asterisk reported my PRI's down, the telco brought the D-channel back in service, and asterisk went back to work. Did not even reboot the machine. PB ___ Asterisk-Users mailing list Asterisk-Users@lists.digium.com http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users
Re: [Asterisk-Users] PRI got event: HDLC Abort (6) on Primary, D-channel of span 1
2 - Check your span line in your zaptel.conf. You should be receiving timing, not giving it, when using a PRI (generally). Change the second number from 1 to 0. Save and restart asterisk. (span=1,0,0,esf,b8zs) I think you've got this cocked-up. A 0 in the second position tells zaptel to internally-clock the circuit, and ingnore the clocking information from the provider. Why would you want to do that? ___ Asterisk-Users mailing list Asterisk-Users@lists.digium.com http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users
Re: [Asterisk-Users] PRI got event: HDLC Abort (6) on Primary D-channel of span 1
On Wed, 20 Jul 2005, Paul Belanger wrote: Any to back my clams that asterisk is fine, I'm using the TE405P, with a different telco in my second span and it operates fine!! What span is your clock source? A TE405P card can only operate in one clock domain at a time. I.e. the same clock will be used on all of them. If both providers are connected to the same TE405P card you will most likely have a problem with one of them unless they in turn have their clocks locked to a common source. Two differently clocked sources wil manifest themselves as the occasional bit slip. I am not sure if a bit slip can cause the problems on the D channel you are seeing. Peter ___ Asterisk-Users mailing list Asterisk-Users@lists.digium.com http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users
Re: [Asterisk-Users] PRI got event: HDLC Abort (6) on Primary D-channel of span 1
try removing asterisk modules you are not using, and non-asterisk services running on the machine, especially ones with high disk or network usage. Kevin wrote: I am getting an error in the log on the PRI span. The error is : PRI got event: HDLC Abort (6) on Primary D-channel of span 1 I thought the problem was an interrupt conflict with the T110P card, so I changed out the server to one that will dedicate the interrupt to the T110P card. I still have the problem. It's a dell 800 server with an SATA drive. Can anyone offer and suggestions as any probable cause? Thanks ___ Asterisk-Users mailing list Asterisk-Users@lists.digium.com http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users ___ Asterisk-Users mailing list Asterisk-Users@lists.digium.com http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users
Re: [Asterisk-Users] PRI got event: HDLC Abort (6) on Primary D-channel of span 1
Michael Blood wrote: I receive this error on the asterisk console and it is pretty much ALWAYS coming up. Sometimes there will be a break where it does not display. This happens when Asterisk receives corrupt data from the card. The most common cause of this is some device or driver locking interrupts for long enough to lose data coming in from the card. Common causes of this are graphics, raid, etc. If the problem only happens when accessing the disk, then you may have to tune your IDE settings using haparm (see google). Some IDE chipsets simply don't work with Digium cards because they lock interrupts for too long. We had this problem with a ServerWorks chipset. The only solution was to replace the motherboard with one from a different company. -- Eric Wieling * BTEL Consulting * 504-210-3699 x2120 ___ Asterisk-Users mailing list Asterisk-Users@lists.digium.com http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users
Re: [Asterisk-Users] PRI got event: HDLC Abort (6) on Primary D-channel of span 1
What does zttool say? Do you have any IRQ issues or anything? -- Tom On 6/29/05, Michael Blood [EMAIL PROTECTED] wrote: I receive this error on the asterisk console and it is pretty much ALWAYS coming up. Sometimes there will be a break where it does not display. We had our PRI provider test the lines and they claim that there is no signalling problem. It doesn't matter if there are no calls or if there are 10 calls in progress the error is still displayed. I also get an annoying popping or clicking sound but that doesn't always correspond with this error coming up so it is likely a separate issue. I have loaded all modules by hand like below as someone suggested in a search for HDLC errors on the list. insmod zaptel insmod wct1xxp Unfortunately it did not help Has anyone run into this in the past? Michael ;zapata.conf switchtype=national context=incoming_eli_pri_1 signalling=pri_cpe group=1 channel = 1-11 bchan=1-11 dchan=24 ;zaptel.conf span=1,1,0,esf,b8zs bchan=1-11 dchan=24 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:07 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:08 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:08 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:08 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:08 NOTICE[3094]: chan_zap.c:7394 pri_dchannel: PRI got event: HDLC Abort (6) on Primary D-channel of span 1 Jun 29 07:09:08 NOTICE[3094]: chan_zap.c:7394