Re: At startup brewtus III-R pressure increases uncontrolled until up to temp...

2017-07-19 Thread Mike Rabin
Thanks Steve, the stat was new but has needed adjustment twice now.
I'm living with it for now but need some new gaskets, so I'll order another
soon.
Cheers,
Mike
On Wed, Jul 19, 2017 at 12:28 PM StevieG.  wrote:

> 6 bar seems a bit low, I have mine set to around 9. You may have a
> pressure stat issue.
>
> --
> You received this message because you are subscribed to a topic in the
> Google Groups "Brewtus" group.
> To unsubscribe from this topic, visit
> https://groups.google.com/d/topic/brewtus/w_3Bm4xXLbE/unsubscribe.
> To unsubscribe from this group and all its topics, send an email to
> brewtus+unsubscr...@googlegroups.com.
> To post to this group, send email to brewtus@googlegroups.com.
> Visit this group at https://groups.google.com/group/brewtus.
> For more options, visit https://groups.google.com/d/optout.
>

-- 
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to brewtus+unsubscr...@googlegroups.com.
To post to this group, send email to brewtus@googlegroups.com.
Visit this group at https://groups.google.com/group/brewtus.
For more options, visit https://groups.google.com/d/optout.


Re: At startup brewtus III-R pressure increases uncontrolled until up to temp...

2017-07-19 Thread StevieG.
6 bar seems a bit low, I have mine set to around 9. You may have a pressure 
stat issue.

-- 
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to brewtus+unsubscr...@googlegroups.com.
To post to this group, send email to brewtus@googlegroups.com.
Visit this group at https://groups.google.com/group/brewtus.
For more options, visit https://groups.google.com/d/optout.


Re: At startup brewtus III-R pressure increases uncontrolled until up to temp...

2017-07-19 Thread Mike Rabin
Back to 6 bar.
Will stay at 6 bar until I brew a shot, then needs to pressure relieved
again after temperature? back to 92degC.
Stays at 6 bar when pump senses low pressure (low level?) runs and is fine
again.

Put a New PID in before, and a pressure stat can't recall if problems were
son after or not...
have Lyme disease so anything possible...



On Wed, Jul 19, 2017 at 7:18 AM StevieG.  wrote:

> Hi Mike,
>
> Interesting issue - once the pressure is relieved, where does it settle to?
>
> --
> You received this message because you are subscribed to a topic in the
> Google Groups "Brewtus" group.
> To unsubscribe from this topic, visit
> https://groups.google.com/d/topic/brewtus/w_3Bm4xXLbE/unsubscribe.
> To unsubscribe from this group and all its topics, send an email to
> brewtus+unsubscr...@googlegroups.com.
> To post to this group, send email to brewtus@googlegroups.com.
> Visit this group at https://groups.google.com/group/brewtus.
> For more options, visit https://groups.google.com/d/optout.
>

-- 
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to brewtus+unsubscr...@googlegroups.com.
To post to this group, send email to brewtus@googlegroups.com.
Visit this group at https://groups.google.com/group/brewtus.
For more options, visit https://groups.google.com/d/optout.


Brewtus II pressurestat

2017-07-19 Thread StevieG.
Guess it's that time again!  I bought a Jaeger in April 2015, and have 
occasionally had it over pressure and blow the relief valve.  Now it is 
becoming more regular.  

It doesn't appear there has been any raving reviews of the Jaeger, with 
many early failures, and I am wondering if anyone has found a better unit 
to go with now?

Ben, what has your experience been the Mater?

Thanks for any input!

-- 
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to brewtus+unsubscr...@googlegroups.com.
To post to this group, send email to brewtus@googlegroups.com.
Visit this group at https://groups.google.com/group/brewtus.
For more options, visit https://groups.google.com/d/optout.


Re: At startup brewtus III-R pressure increases uncontrolled until up to temp...

2017-07-19 Thread StevieG.
Hi Mike,

Interesting issue - once the pressure is relieved, where does it settle to?

-- 
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to brewtus+unsubscr...@googlegroups.com.
To post to this group, send email to brewtus@googlegroups.com.
Visit this group at https://groups.google.com/group/brewtus.
For more options, visit https://groups.google.com/d/optout.