Re: [ceph-users] Luminous - bad performance

2018-01-25 Thread Steven Vacaroaia
Hi,
setting the pplication pool helped - the performance is not skewed anymore
( i.e. SSDpool is better than HDD)
However latency when using more threads is still very high

I am getting 9.91 Gbits/sec when testing with iperf

Not sure what else should I check
As always, your help will be greatly appreciated

using 1 hread ( -t 1)

Total writes made:  1627
Write size: 4194304
Object size:4194304
Bandwidth (MB/sec): 108.387
Stddev Bandwidth:   9.75056
Max bandwidth (MB/sec): 128
Min bandwidth (MB/sec): 92
Average IOPS:   27
Stddev IOPS:2
Max IOPS:   32
Min IOPS:   23
Average Latency(s): 0.0369025
Stddev Latency(s):  0.0161718
Max latency(s): 0.258894
Min latency(s): 0.0133281




using 32 threads ( -t 32 )

Total writes made:  2348
Write size: 4194304
Object size:4194304
Bandwidth (MB/sec): 143.244
Stddev Bandwidth:   124.265
Max bandwidth (MB/sec): 420
Min bandwidth (MB/sec): 0
Average IOPS:   35
Stddev IOPS:31
Max IOPS:   105
Min IOPS:   0
Average Latency(s): 0.892837
Stddev Latency(s):  1.97054
Max latency(s): 14.0602
Min latency(s): 0.0250363


On 24 January 2018 at 15:03, Marc Roos  wrote:

>
>
> ceph osd pool application enable XXX rbd
>
> -Original Message-
> From: Steven Vacaroaia [mailto:ste...@gmail.com]
> Sent: woensdag 24 januari 2018 19:47
> To: David Turner
> Cc: ceph-users
> Subject: Re: [ceph-users] Luminous - bad performance
>
> Hi ,
>
> I have bundled the public NICs and added 2 more monitors ( running on 2
> of the 3 OSD hosts) This seem to improve  things but still I have high
> latency Also performance of the SSD pool is worse than HDD which is very
> confusing
>
> SSDpool is using one Toshiba PX05SMB040Y per server ( for a total of 3
> OSDs) while HDD pool is using 2 Seagate ST600MM0006 disks per server ()
> for a total of 6 OSDs)
>
> Note
> I have also disabled  C state in the BIOS and added
> "intel_pstate=disable intel_idle.max_cstate=0 processor.max_cstate=0
> idle=poll" to GRUB
>
> Any hints/suggestions will be greatly appreciated
>
> [root@osd04 ~]# ceph status
>   cluster:
> id: 37161a51-a159-4895-a7fd-3b0d857f1b66
> health: HEALTH_WARN
> noscrub,nodeep-scrub flag(s) set
> application not enabled on 2 pool(s)
> mon osd02 is low on available space
>
>   services:
> mon: 3 daemons, quorum osd01,osd02,mon01
> mgr: mon01(active)
> osd: 9 osds: 9 up, 9 in
>  flags noscrub,nodeep-scrub
> tcmu-runner: 6 daemons active
>
>   data:
> pools:   2 pools, 228 pgs
> objects: 50384 objects, 196 GB
> usage:   402 GB used, 3504 GB / 3906 GB avail
> pgs: 228 active+clean
>
>   io:
> client:   46061 kB/s rd, 852 B/s wr, 15 op/s rd, 0 op/s wr
>
> [root@osd04 ~]# ceph osd tree
> ID  CLASS WEIGHT  TYPE NAME  STATUS REWEIGHT PRI-AFF
>  -9   4.5 root ssds
> -10   1.5 host osd01-ssd
>   6   hdd 1.5 osd.6  up  1.0 1.0
> -11   1.5 host osd02-ssd
>   7   hdd 1.5 osd.7  up  1.0 1.0
> -12   1.5 host osd04-ssd
>   8   hdd 1.5 osd.8  up  1.0 1.0
>  -1   2.72574 root default
>  -3   1.09058 host osd01
>   0   hdd 0.54529 osd.0  up  1.0 1.0
>   4   hdd 0.54529 osd.4  up  1.0 1.0
>  -5   1.09058 host osd02
>   1   hdd 0.54529 osd.1  up  1.0 1.0
>   3   hdd 0.54529 osd.3  up  1.0 1.0
>  -7   0.54459 host osd04
>   2   hdd 0.27229 osd.2  up  1.0 1.0
>   5   hdd 0.27229 osd.5  up  1.0 1.0
>
>
>  rados bench -p ssdpool 300 -t 32 write --no-cleanup && rados bench -p
> ssdpool 300 -t 32  seq
>
> Total time run: 302.058832
> Total writes made:  4100
> Write size: 4194304
> Object size:4194304
> Bandwidth (MB/sec): 54.2941
> Stddev Bandwidth:   70.3355
> Max bandwidth (MB/sec): 252
> Min bandwidth (MB/sec): 0
> Average IOPS:   13
> Stddev IOPS:17
> Max IOPS:   63
> Min IOPS:   0
> Average Latency(s): 2.35655
> Stddev Latency(s):  4.4346
> Max latency(s): 29.7027
> Min latency(s): 0.045166
>
> rados bench -p rbd 300 -t 32 write --no-cleanup && rados bench -p rbd
> 300 -t 32  seq
> Total time run: 301.428571
> Total writes made:  8753
> Wri

Re: [ceph-users] Luminous - bad performance

2018-01-24 Thread Marc Roos
 

ceph osd pool application enable XXX rbd

-Original Message-
From: Steven Vacaroaia [mailto:ste...@gmail.com] 
Sent: woensdag 24 januari 2018 19:47
To: David Turner
Cc: ceph-users
Subject: Re: [ceph-users] Luminous - bad performance

Hi ,

I have bundled the public NICs and added 2 more monitors ( running on 2 
of the 3 OSD hosts) This seem to improve  things but still I have high 
latency Also performance of the SSD pool is worse than HDD which is very 
confusing 

SSDpool is using one Toshiba PX05SMB040Y per server ( for a total of 3 
OSDs) while HDD pool is using 2 Seagate ST600MM0006 disks per server () 
for a total of 6 OSDs)

Note
I have also disabled  C state in the BIOS and added  
"intel_pstate=disable intel_idle.max_cstate=0 processor.max_cstate=0 
idle=poll" to GRUB

Any hints/suggestions will be greatly appreciated 

[root@osd04 ~]# ceph status
  cluster:
id: 37161a51-a159-4895-a7fd-3b0d857f1b66
health: HEALTH_WARN
noscrub,nodeep-scrub flag(s) set
application not enabled on 2 pool(s)
mon osd02 is low on available space

  services:
mon: 3 daemons, quorum osd01,osd02,mon01
mgr: mon01(active)
osd: 9 osds: 9 up, 9 in
 flags noscrub,nodeep-scrub
tcmu-runner: 6 daemons active

  data:
pools:   2 pools, 228 pgs
objects: 50384 objects, 196 GB
usage:   402 GB used, 3504 GB / 3906 GB avail
pgs: 228 active+clean

  io:
client:   46061 kB/s rd, 852 B/s wr, 15 op/s rd, 0 op/s wr

[root@osd04 ~]# ceph osd tree
ID  CLASS WEIGHT  TYPE NAME  STATUS REWEIGHT PRI-AFF
 -9   4.5 root ssds
-10   1.5 host osd01-ssd
  6   hdd 1.5 osd.6  up  1.0 1.0
-11   1.5 host osd02-ssd
  7   hdd 1.5 osd.7  up  1.0 1.0
-12   1.5 host osd04-ssd
  8   hdd 1.5 osd.8  up  1.0 1.0
 -1   2.72574 root default
 -3   1.09058 host osd01
  0   hdd 0.54529 osd.0  up  1.0 1.0
  4   hdd 0.54529 osd.4  up  1.0 1.0
 -5   1.09058 host osd02
  1   hdd 0.54529 osd.1  up  1.0 1.0
  3   hdd 0.54529 osd.3  up  1.0 1.0
 -7   0.54459 host osd04
  2   hdd 0.27229 osd.2  up  1.0 1.0
  5   hdd 0.27229 osd.5  up  1.0 1.0


 rados bench -p ssdpool 300 -t 32 write --no-cleanup && rados bench -p 
ssdpool 300 -t 32  seq

Total time run: 302.058832
Total writes made:  4100
Write size: 4194304
Object size:4194304
Bandwidth (MB/sec): 54.2941
Stddev Bandwidth:   70.3355
Max bandwidth (MB/sec): 252
Min bandwidth (MB/sec): 0
Average IOPS:   13
Stddev IOPS:17
Max IOPS:   63
Min IOPS:   0
Average Latency(s): 2.35655
Stddev Latency(s):  4.4346
Max latency(s): 29.7027
Min latency(s): 0.045166

rados bench -p rbd 300 -t 32 write --no-cleanup && rados bench -p rbd 
300 -t 32  seq
Total time run: 301.428571
Total writes made:  8753
Write size: 4194304
Object size:4194304
Bandwidth (MB/sec): 116.154
Stddev Bandwidth:   71.5763
Max bandwidth (MB/sec): 320
Min bandwidth (MB/sec): 0
Average IOPS:   29
Stddev IOPS:17
Max IOPS:   80
Min IOPS:   0
Average Latency(s): 1.10189
Stddev Latency(s):  1.80203
Max latency(s): 15.0715
Min latency(s): 0.0210309




[root@osd04 ~]# ethtool -k gth0
Features for gth0:
rx-checksumming: on
tx-checksumming: on
tx-checksum-ipv4: off [fixed]
tx-checksum-ip-generic: on
tx-checksum-ipv6: off [fixed]
tx-checksum-fcoe-crc: on [fixed]
tx-checksum-sctp: on
scatter-gather: on
tx-scatter-gather: on
tx-scatter-gather-fraglist: off [fixed]
tcp-segmentation-offload: on
tx-tcp-segmentation: on
tx-tcp-ecn-segmentation: off [fixed]
tx-tcp-mangleid-segmentation: off
tx-tcp6-segmentation: on
udp-fragmentation-offload: off [fixed]
generic-segmentation-offload: on
generic-receive-offload: on
large-receive-offload: off
rx-vlan-offload: on
tx-vlan-offload: on
ntuple-filters: off
receive-hashing: on
highdma: on [fixed]
rx-vlan-filter: on
vlan-challenged: off [fixed]
tx-lockless: off [fixed]
netns-local: off [fixed]
tx-gso-robust: off [fixed]
tx-fcoe-segmentation: on [fixed]
tx-gre-segmentation: on
tx-gre-csum-segmentation: on
tx-ipxip4-segmentation: on
tx-ipxip6-segmentation: on
tx-udp_tnl-segmentation: on
tx-udp_tnl-csum-segmentation: on
tx-gso-partial: on
tx-sctp-segmentation: off [fixed]
tx-esp-segmentation: off [fixed]
fcoe-mtu: off [fixed]
tx-nocache-copy: off
loopback: off [fixed]
rx-fcs: off [fixed]
rx-all: off
tx-vlan-stag-hw-insert: off [fixed]
rx-vlan-stag-hw-parse: off [fixed]
rx-vlan-s

Re: [ceph-users] Luminous - bad performance

2018-01-24 Thread Steven Vacaroaia
Hi ,

I have bundled the public NICs and added 2 more monitors ( running on 2 of
the 3 OSD hosts)
This seem to improve  things but still I have high latency
Also performance of the SSD pool is worse than HDD which is very confusing

SSDpool is using one Toshiba PX05SMB040Y per server ( for a total of 3
OSDs)
while HDD pool is using 2 Seagate ST600MM0006 disks per server () for a
total of 6 OSDs)

Note
I have also disabled  C state in the BIOS and added  "intel_pstate=disable
intel_idle.max_cstate=0 processor.max_cstate=0 idle=poll" to GRUB

Any hints/suggestions will be greatly appreciated

[root@osd04 ~]# ceph status
  cluster:
id: 37161a51-a159-4895-a7fd-3b0d857f1b66
health: HEALTH_WARN
noscrub,nodeep-scrub flag(s) set
application not enabled on 2 pool(s)
mon osd02 is low on available space

  services:
mon: 3 daemons, quorum osd01,osd02,mon01
mgr: mon01(active)
osd: 9 osds: 9 up, 9 in
 flags noscrub,nodeep-scrub
tcmu-runner: 6 daemons active

  data:
pools:   2 pools, 228 pgs
objects: 50384 objects, 196 GB
usage:   402 GB used, 3504 GB / 3906 GB avail
pgs: 228 active+clean

  io:
client:   46061 kB/s rd, 852 B/s wr, 15 op/s rd, 0 op/s wr

[root@osd04 ~]# ceph osd tree
ID  CLASS WEIGHT  TYPE NAME  STATUS REWEIGHT PRI-AFF
 -9   4.5 root ssds
-10   1.5 host osd01-ssd
  6   hdd 1.5 osd.6  up  1.0 1.0
-11   1.5 host osd02-ssd
  7   hdd 1.5 osd.7  up  1.0 1.0
-12   1.5 host osd04-ssd
  8   hdd 1.5 osd.8  up  1.0 1.0
 -1   2.72574 root default
 -3   1.09058 host osd01
  0   hdd 0.54529 osd.0  up  1.0 1.0
  4   hdd 0.54529 osd.4  up  1.0 1.0
 -5   1.09058 host osd02
  1   hdd 0.54529 osd.1  up  1.0 1.0
  3   hdd 0.54529 osd.3  up  1.0 1.0
 -7   0.54459 host osd04
  2   hdd 0.27229 osd.2  up  1.0 1.0
  5   hdd 0.27229 osd.5  up  1.0 1.0


 rados bench -p ssdpool 300 -t 32 write --no-cleanup && rados bench -p
ssdpool 300 -t 32  seq
Total time run: 302.058832
Total writes made:  4100
Write size: 4194304
Object size:4194304
Bandwidth (MB/sec): 54.2941
Stddev Bandwidth:   70.3355
Max bandwidth (MB/sec): 252
Min bandwidth (MB/sec): 0
Average IOPS:   13
Stddev IOPS:17
Max IOPS:   63
Min IOPS:   0
Average Latency(s): 2.35655
Stddev Latency(s):  4.4346
Max latency(s): 29.7027
Min latency(s): 0.045166

rados bench -p rbd 300 -t 32 write --no-cleanup && rados bench -p rbd 300
-t 32  seq
Total time run: 301.428571
Total writes made:  8753
Write size: 4194304
Object size:4194304
Bandwidth (MB/sec): 116.154
Stddev Bandwidth:   71.5763
Max bandwidth (MB/sec): 320
Min bandwidth (MB/sec): 0
Average IOPS:   29
Stddev IOPS:17
Max IOPS:   80
Min IOPS:   0
Average Latency(s): 1.10189
Stddev Latency(s):  1.80203
Max latency(s): 15.0715
Min latency(s): 0.0210309




[root@osd04 ~]# ethtool -k gth0
Features for gth0:
rx-checksumming: on
tx-checksumming: on
tx-checksum-ipv4: off [fixed]
tx-checksum-ip-generic: on
tx-checksum-ipv6: off [fixed]
tx-checksum-fcoe-crc: on [fixed]
tx-checksum-sctp: on
scatter-gather: on
tx-scatter-gather: on
tx-scatter-gather-fraglist: off [fixed]
tcp-segmentation-offload: on
tx-tcp-segmentation: on
tx-tcp-ecn-segmentation: off [fixed]
tx-tcp-mangleid-segmentation: off
tx-tcp6-segmentation: on
udp-fragmentation-offload: off [fixed]
generic-segmentation-offload: on
generic-receive-offload: on
large-receive-offload: off
rx-vlan-offload: on
tx-vlan-offload: on
ntuple-filters: off
receive-hashing: on
highdma: on [fixed]
rx-vlan-filter: on
vlan-challenged: off [fixed]
tx-lockless: off [fixed]
netns-local: off [fixed]
tx-gso-robust: off [fixed]
tx-fcoe-segmentation: on [fixed]
tx-gre-segmentation: on
tx-gre-csum-segmentation: on
tx-ipxip4-segmentation: on
tx-ipxip6-segmentation: on
tx-udp_tnl-segmentation: on
tx-udp_tnl-csum-segmentation: on
tx-gso-partial: on
tx-sctp-segmentation: off [fixed]
tx-esp-segmentation: off [fixed]
fcoe-mtu: off [fixed]
tx-nocache-copy: off
loopback: off [fixed]
rx-fcs: off [fixed]
rx-all: off
tx-vlan-stag-hw-insert: off [fixed]
rx-vlan-stag-hw-parse: off [fixed]
rx-vlan-stag-filter: off [fixed]
l2-fwd-offload: off
hw-tc-offload: off
esp-hw-offload: off [fixed]
esp-tx-csum-hw-offload: off [fixed]



On 22 January 2018 at 12:09, Steven Vacaroaia  wrote:

> Hi David,
>
> I noticed the public interface of the server I am running the test from is
> heavily 

Re: [ceph-users] Luminous - bad performance

2018-01-22 Thread Steven Vacaroaia
Hi David,

I noticed the public interface of the server I am running the test from is
heavily used  so I will bond that one too

I doubt though that this explains the poor performance

Thanks for your advice

Steven



On 22 January 2018 at 12:02, David Turner  wrote:

> I'm not speaking to anything other than your configuration.
>
> "I am using 2 x 10 GB bonded ( BONDING_OPTS="mode=4 miimon=100
> xmit_hash_policy=1 lacp_rate=1")  for cluster and 1 x 1GB for public"
> It might not be a bad idea for you to forgo the public network on the 1Gb
> interfaces and either put everything on one network or use VLANs on the
> 10Gb connections.  I lean more towards that in particular because your
> public network doesn't have a bond on it.  Just as a note, communication
> between the OSDs and the MONs are all done on the public network.  If that
> interface goes down, then the OSDs are likely to be marked down/out from
> your cluster.  I'm a fan of VLANs, but if you don't have the equipment or
> expertise to go that route, then just using the same subnet for public and
> private is a decent way to go.
>
> On Mon, Jan 22, 2018 at 11:37 AM Steven Vacaroaia 
> wrote:
>
>> I did test with rados bench ..here are the results
>>
>> rados bench -p ssdpool 300 -t 12 write --no-cleanup && rados bench -p
>> ssdpool 300 -t 12  seq
>>
>> Total time run: 300.322608
>> Total writes made:  10632
>> Write size: 4194304
>> Object size:4194304
>> Bandwidth (MB/sec): 141.608
>> Stddev Bandwidth:   74.1065
>> Max bandwidth (MB/sec): 264
>> Min bandwidth (MB/sec): 0
>> Average IOPS:   35
>> Stddev IOPS:18
>> Max IOPS:   66
>> Min IOPS:   0
>> Average Latency(s): 0.33887
>> Stddev Latency(s):  0.701947
>> Max latency(s): 9.80161
>> Min latency(s): 0.015171
>>
>> Total time run:   300.829945
>> Total reads made: 10070
>> Read size:4194304
>> Object size:  4194304
>> Bandwidth (MB/sec):   133.896
>> Average IOPS: 33
>> Stddev IOPS:  14
>> Max IOPS: 68
>> Min IOPS: 3
>> Average Latency(s):   0.35791
>> Max latency(s):   4.68213
>> Min latency(s):   0.0107572
>>
>>
>> rados bench -p scbench256 300 -t 12 write --no-cleanup && rados bench -p
>> scbench256 300 -t 12  seq
>>
>> Total time run: 300.747004
>> Total writes made:  10239
>> Write size: 4194304
>> Object size:4194304
>> Bandwidth (MB/sec): 136.181
>> Stddev Bandwidth:   75.5
>> Max bandwidth (MB/sec): 272
>> Min bandwidth (MB/sec): 0
>> Average IOPS:   34
>> Stddev IOPS:18
>> Max IOPS:   68
>> Min IOPS:   0
>> Average Latency(s): 0.352339
>> Stddev Latency(s):  0.72211
>> Max latency(s): 9.62304
>> Min latency(s): 0.00936316
>> hints = 1
>>
>>
>> Total time run:   300.610761
>> Total reads made: 7628
>> Read size:4194304
>> Object size:  4194304
>> Bandwidth (MB/sec):   101.5
>> Average IOPS: 25
>> Stddev IOPS:  11
>> Max IOPS: 61
>> Min IOPS: 0
>> Average Latency(s):   0.472321
>> Max latency(s):   15.636
>> Min latency(s):   0.0188098
>>
>>
>> On 22 January 2018 at 11:34, Steven Vacaroaia  wrote:
>>
>>> sorry ..send the message too soon
>>> Here is more info
>>> Vendor Id  : SEAGATE
>>> Product Id : ST600MM0006
>>> State  : Online
>>> Disk Type  : SAS,Hard Disk Device
>>> Capacity   : 558.375 GB
>>> Power State: Active
>>>
>>> ( SSD is in slot 0)
>>>
>>>  megacli -LDGetProp  -Cache -LALL -a0
>>>
>>> Adapter 0-VD 0(target id: 0): Cache Policy:WriteThrough, ReadAheadNone,
>>> Direct, No Write Cache if bad BBU
>>> Adapter 0-VD 1(target id: 1): Cache Policy:WriteBack, ReadAdaptive,
>>> Direct, No Write Cache if bad BBU
>>> Adapter 0-VD 2(target id: 2): Cache Policy:WriteBack, ReadAdaptive,
>>> Direct, No Write Cache if bad BBU
>>> Adapter 0-VD 3(target id: 3): Cache Policy:WriteBack, ReadAdaptive,
>>> Direct, No Write Cache if bad BBU
>>> Adapter 0-VD 4(target id: 4): Cache Policy:WriteBack, ReadAdaptive,
>>> Direct, No Write Cache if bad BBU
>>> Adapter 0-VD 5(target id: 5): Cache Policy:WriteBack, ReadAdaptive,
>>> Direct, No Write Cache if bad BBU
>>>
>>> [root@osd01 ~]#  megacli -LDGetProp  -DskCache -LALL -a0
>>>
>>> Adapter 0-VD 0(target id: 0): Disk Write Cache : Disabled
>>> Adapter 0-VD 1(target id: 1): Disk Write Cache : Disk's Default
>>> Adapter 0-VD 2(target id: 2): Disk Write Cache : Disk's Default
>>> Adapter 0-VD 3(target id: 3): Disk Write Cache : Disk's Default
>>> Adapter 0-VD 4(target id: 4): Disk Write Cache : Disk's Default
>>> Adapter 0-VD 5(target id: 5): Disk Write Cache : Disk's Default
>>>
>>>
>>> CPU
>>> Intel(R) Xeon(R) CPU E5-2640 0 @ 2.50GHz
>>>
>>> Centos 7 ke

Re: [ceph-users] Luminous - bad performance

2018-01-22 Thread David Turner
I'm not speaking to anything other than your configuration.

"I am using 2 x 10 GB bonded ( BONDING_OPTS="mode=4 miimon=100
xmit_hash_policy=1 lacp_rate=1")  for cluster and 1 x 1GB for public"
It might not be a bad idea for you to forgo the public network on the 1Gb
interfaces and either put everything on one network or use VLANs on the
10Gb connections.  I lean more towards that in particular because your
public network doesn't have a bond on it.  Just as a note, communication
between the OSDs and the MONs are all done on the public network.  If that
interface goes down, then the OSDs are likely to be marked down/out from
your cluster.  I'm a fan of VLANs, but if you don't have the equipment or
expertise to go that route, then just using the same subnet for public and
private is a decent way to go.

On Mon, Jan 22, 2018 at 11:37 AM Steven Vacaroaia  wrote:

> I did test with rados bench ..here are the results
>
> rados bench -p ssdpool 300 -t 12 write --no-cleanup && rados bench -p
> ssdpool 300 -t 12  seq
>
> Total time run: 300.322608
> Total writes made:  10632
> Write size: 4194304
> Object size:4194304
> Bandwidth (MB/sec): 141.608
> Stddev Bandwidth:   74.1065
> Max bandwidth (MB/sec): 264
> Min bandwidth (MB/sec): 0
> Average IOPS:   35
> Stddev IOPS:18
> Max IOPS:   66
> Min IOPS:   0
> Average Latency(s): 0.33887
> Stddev Latency(s):  0.701947
> Max latency(s): 9.80161
> Min latency(s): 0.015171
>
> Total time run:   300.829945
> Total reads made: 10070
> Read size:4194304
> Object size:  4194304
> Bandwidth (MB/sec):   133.896
> Average IOPS: 33
> Stddev IOPS:  14
> Max IOPS: 68
> Min IOPS: 3
> Average Latency(s):   0.35791
> Max latency(s):   4.68213
> Min latency(s):   0.0107572
>
>
> rados bench -p scbench256 300 -t 12 write --no-cleanup && rados bench -p
> scbench256 300 -t 12  seq
>
> Total time run: 300.747004
> Total writes made:  10239
> Write size: 4194304
> Object size:4194304
> Bandwidth (MB/sec): 136.181
> Stddev Bandwidth:   75.5
> Max bandwidth (MB/sec): 272
> Min bandwidth (MB/sec): 0
> Average IOPS:   34
> Stddev IOPS:18
> Max IOPS:   68
> Min IOPS:   0
> Average Latency(s): 0.352339
> Stddev Latency(s):  0.72211
> Max latency(s): 9.62304
> Min latency(s): 0.00936316
> hints = 1
>
>
> Total time run:   300.610761
> Total reads made: 7628
> Read size:4194304
> Object size:  4194304
> Bandwidth (MB/sec):   101.5
> Average IOPS: 25
> Stddev IOPS:  11
> Max IOPS: 61
> Min IOPS: 0
> Average Latency(s):   0.472321
> Max latency(s):   15.636
> Min latency(s):   0.0188098
>
>
> On 22 January 2018 at 11:34, Steven Vacaroaia  wrote:
>
>> sorry ..send the message too soon
>> Here is more info
>> Vendor Id  : SEAGATE
>> Product Id : ST600MM0006
>> State  : Online
>> Disk Type  : SAS,Hard Disk Device
>> Capacity   : 558.375 GB
>> Power State: Active
>>
>> ( SSD is in slot 0)
>>
>>  megacli -LDGetProp  -Cache -LALL -a0
>>
>> Adapter 0-VD 0(target id: 0): Cache Policy:WriteThrough, ReadAheadNone,
>> Direct, No Write Cache if bad BBU
>> Adapter 0-VD 1(target id: 1): Cache Policy:WriteBack, ReadAdaptive,
>> Direct, No Write Cache if bad BBU
>> Adapter 0-VD 2(target id: 2): Cache Policy:WriteBack, ReadAdaptive,
>> Direct, No Write Cache if bad BBU
>> Adapter 0-VD 3(target id: 3): Cache Policy:WriteBack, ReadAdaptive,
>> Direct, No Write Cache if bad BBU
>> Adapter 0-VD 4(target id: 4): Cache Policy:WriteBack, ReadAdaptive,
>> Direct, No Write Cache if bad BBU
>> Adapter 0-VD 5(target id: 5): Cache Policy:WriteBack, ReadAdaptive,
>> Direct, No Write Cache if bad BBU
>>
>> [root@osd01 ~]#  megacli -LDGetProp  -DskCache -LALL -a0
>>
>> Adapter 0-VD 0(target id: 0): Disk Write Cache : Disabled
>> Adapter 0-VD 1(target id: 1): Disk Write Cache : Disk's Default
>> Adapter 0-VD 2(target id: 2): Disk Write Cache : Disk's Default
>> Adapter 0-VD 3(target id: 3): Disk Write Cache : Disk's Default
>> Adapter 0-VD 4(target id: 4): Disk Write Cache : Disk's Default
>> Adapter 0-VD 5(target id: 5): Disk Write Cache : Disk's Default
>>
>>
>> CPU
>> Intel(R) Xeon(R) CPU E5-2640 0 @ 2.50GHz
>>
>> Centos 7 kernel 3.10.0-693.11.6.el7.x86_64
>>
>> sysctl -p
>> net.ipv4.tcp_sack = 0
>> net.core.netdev_budget = 600
>> net.ipv4.tcp_window_scaling = 1
>> net.core.rmem_max = 16777216
>> net.core.wmem_max = 16777216
>> net.core.rmem_default = 16777216
>> net.core.wmem_default = 16777216
>> net.core.optmem_max = 40960
>> net.ipv4.tcp_rmem = 4096 87380 16777216
>> net.ipv4.tcp_wmem = 4096 65536 16777216
>> net.ipv4.tcp_syncoo

Re: [ceph-users] Luminous - bad performance

2018-01-22 Thread Steven Vacaroaia
I did test with rados bench ..here are the results

rados bench -p ssdpool 300 -t 12 write --no-cleanup && rados bench -p
ssdpool 300 -t 12  seq

Total time run: 300.322608
Total writes made:  10632
Write size: 4194304
Object size:4194304
Bandwidth (MB/sec): 141.608
Stddev Bandwidth:   74.1065
Max bandwidth (MB/sec): 264
Min bandwidth (MB/sec): 0
Average IOPS:   35
Stddev IOPS:18
Max IOPS:   66
Min IOPS:   0
Average Latency(s): 0.33887
Stddev Latency(s):  0.701947
Max latency(s): 9.80161
Min latency(s): 0.015171

Total time run:   300.829945
Total reads made: 10070
Read size:4194304
Object size:  4194304
Bandwidth (MB/sec):   133.896
Average IOPS: 33
Stddev IOPS:  14
Max IOPS: 68
Min IOPS: 3
Average Latency(s):   0.35791
Max latency(s):   4.68213
Min latency(s):   0.0107572


rados bench -p scbench256 300 -t 12 write --no-cleanup && rados bench -p
scbench256 300 -t 12  seq

Total time run: 300.747004
Total writes made:  10239
Write size: 4194304
Object size:4194304
Bandwidth (MB/sec): 136.181
Stddev Bandwidth:   75.5
Max bandwidth (MB/sec): 272
Min bandwidth (MB/sec): 0
Average IOPS:   34
Stddev IOPS:18
Max IOPS:   68
Min IOPS:   0
Average Latency(s): 0.352339
Stddev Latency(s):  0.72211
Max latency(s): 9.62304
Min latency(s): 0.00936316
hints = 1


Total time run:   300.610761
Total reads made: 7628
Read size:4194304
Object size:  4194304
Bandwidth (MB/sec):   101.5
Average IOPS: 25
Stddev IOPS:  11
Max IOPS: 61
Min IOPS: 0
Average Latency(s):   0.472321
Max latency(s):   15.636
Min latency(s):   0.0188098


On 22 January 2018 at 11:34, Steven Vacaroaia  wrote:

> sorry ..send the message too soon
> Here is more info
> Vendor Id  : SEAGATE
> Product Id : ST600MM0006
> State  : Online
> Disk Type  : SAS,Hard Disk Device
> Capacity   : 558.375 GB
> Power State: Active
>
> ( SSD is in slot 0)
>
>  megacli -LDGetProp  -Cache -LALL -a0
>
> Adapter 0-VD 0(target id: 0): Cache Policy:WriteThrough, ReadAheadNone,
> Direct, No Write Cache if bad BBU
> Adapter 0-VD 1(target id: 1): Cache Policy:WriteBack, ReadAdaptive,
> Direct, No Write Cache if bad BBU
> Adapter 0-VD 2(target id: 2): Cache Policy:WriteBack, ReadAdaptive,
> Direct, No Write Cache if bad BBU
> Adapter 0-VD 3(target id: 3): Cache Policy:WriteBack, ReadAdaptive,
> Direct, No Write Cache if bad BBU
> Adapter 0-VD 4(target id: 4): Cache Policy:WriteBack, ReadAdaptive,
> Direct, No Write Cache if bad BBU
> Adapter 0-VD 5(target id: 5): Cache Policy:WriteBack, ReadAdaptive,
> Direct, No Write Cache if bad BBU
>
> [root@osd01 ~]#  megacli -LDGetProp  -DskCache -LALL -a0
>
> Adapter 0-VD 0(target id: 0): Disk Write Cache : Disabled
> Adapter 0-VD 1(target id: 1): Disk Write Cache : Disk's Default
> Adapter 0-VD 2(target id: 2): Disk Write Cache : Disk's Default
> Adapter 0-VD 3(target id: 3): Disk Write Cache : Disk's Default
> Adapter 0-VD 4(target id: 4): Disk Write Cache : Disk's Default
> Adapter 0-VD 5(target id: 5): Disk Write Cache : Disk's Default
>
>
> CPU
> Intel(R) Xeon(R) CPU E5-2640 0 @ 2.50GHz
>
> Centos 7 kernel 3.10.0-693.11.6.el7.x86_64
>
> sysctl -p
> net.ipv4.tcp_sack = 0
> net.core.netdev_budget = 600
> net.ipv4.tcp_window_scaling = 1
> net.core.rmem_max = 16777216
> net.core.wmem_max = 16777216
> net.core.rmem_default = 16777216
> net.core.wmem_default = 16777216
> net.core.optmem_max = 40960
> net.ipv4.tcp_rmem = 4096 87380 16777216
> net.ipv4.tcp_wmem = 4096 65536 16777216
> net.ipv4.tcp_syncookies = 0
> net.core.somaxconn = 1024
> net.core.netdev_max_backlog = 2
> net.ipv4.tcp_max_syn_backlog = 3
> net.ipv4.tcp_max_tw_buckets = 200
> net.ipv4.tcp_tw_reuse = 1
> net.ipv4.tcp_slow_start_after_idle = 0
> net.ipv4.conf.all.send_redirects = 0
> net.ipv4.conf.all.accept_redirects = 0
> net.ipv4.conf.all.accept_source_route = 0
> vm.min_free_kbytes = 262144
> vm.swappiness = 0
> vm.vfs_cache_pressure = 100
> fs.suid_dumpable = 0
> kernel.core_uses_pid = 1
> kernel.msgmax = 65536
> kernel.msgmnb = 65536
> kernel.randomize_va_space = 1
> kernel.sysrq = 0
> kernel.pid_max = 4194304
> fs.file-max = 10
>
>
> ceph.conf
>
>
> public_network = 10.10.30.0/24
> cluster_network = 192.168.0.0/24
>
>
> osd_op_num_threads_per_shard = 2
> osd_op_num_shards = 25
> osd_pool_default_size = 2
> osd_pool_default_min_size = 1 # Allow writing 1 copy in a degraded state
> osd_pool_default_pg_num = 256
> osd_pool_default_pgp_num = 256
> osd_crush_chooseleaf_type = 1
> osd_scrub_load_threshold = 0.01
> osd_scrub_min_interval = 137438953472
> osd_scru

Re: [ceph-users] Luminous - bad performance

2018-01-22 Thread Steven Vacaroaia
sorry ..send the message too soon
Here is more info
Vendor Id  : SEAGATE
Product Id : ST600MM0006
State  : Online
Disk Type  : SAS,Hard Disk Device
Capacity   : 558.375 GB
Power State: Active

( SSD is in slot 0)

 megacli -LDGetProp  -Cache -LALL -a0

Adapter 0-VD 0(target id: 0): Cache Policy:WriteThrough, ReadAheadNone,
Direct, No Write Cache if bad BBU
Adapter 0-VD 1(target id: 1): Cache Policy:WriteBack, ReadAdaptive, Direct,
No Write Cache if bad BBU
Adapter 0-VD 2(target id: 2): Cache Policy:WriteBack, ReadAdaptive, Direct,
No Write Cache if bad BBU
Adapter 0-VD 3(target id: 3): Cache Policy:WriteBack, ReadAdaptive, Direct,
No Write Cache if bad BBU
Adapter 0-VD 4(target id: 4): Cache Policy:WriteBack, ReadAdaptive, Direct,
No Write Cache if bad BBU
Adapter 0-VD 5(target id: 5): Cache Policy:WriteBack, ReadAdaptive, Direct,
No Write Cache if bad BBU

[root@osd01 ~]#  megacli -LDGetProp  -DskCache -LALL -a0

Adapter 0-VD 0(target id: 0): Disk Write Cache : Disabled
Adapter 0-VD 1(target id: 1): Disk Write Cache : Disk's Default
Adapter 0-VD 2(target id: 2): Disk Write Cache : Disk's Default
Adapter 0-VD 3(target id: 3): Disk Write Cache : Disk's Default
Adapter 0-VD 4(target id: 4): Disk Write Cache : Disk's Default
Adapter 0-VD 5(target id: 5): Disk Write Cache : Disk's Default


CPU
Intel(R) Xeon(R) CPU E5-2640 0 @ 2.50GHz

Centos 7 kernel 3.10.0-693.11.6.el7.x86_64

sysctl -p
net.ipv4.tcp_sack = 0
net.core.netdev_budget = 600
net.ipv4.tcp_window_scaling = 1
net.core.rmem_max = 16777216
net.core.wmem_max = 16777216
net.core.rmem_default = 16777216
net.core.wmem_default = 16777216
net.core.optmem_max = 40960
net.ipv4.tcp_rmem = 4096 87380 16777216
net.ipv4.tcp_wmem = 4096 65536 16777216
net.ipv4.tcp_syncookies = 0
net.core.somaxconn = 1024
net.core.netdev_max_backlog = 2
net.ipv4.tcp_max_syn_backlog = 3
net.ipv4.tcp_max_tw_buckets = 200
net.ipv4.tcp_tw_reuse = 1
net.ipv4.tcp_slow_start_after_idle = 0
net.ipv4.conf.all.send_redirects = 0
net.ipv4.conf.all.accept_redirects = 0
net.ipv4.conf.all.accept_source_route = 0
vm.min_free_kbytes = 262144
vm.swappiness = 0
vm.vfs_cache_pressure = 100
fs.suid_dumpable = 0
kernel.core_uses_pid = 1
kernel.msgmax = 65536
kernel.msgmnb = 65536
kernel.randomize_va_space = 1
kernel.sysrq = 0
kernel.pid_max = 4194304
fs.file-max = 10


ceph.conf


public_network = 10.10.30.0/24
cluster_network = 192.168.0.0/24


osd_op_num_threads_per_shard = 2
osd_op_num_shards = 25
osd_pool_default_size = 2
osd_pool_default_min_size = 1 # Allow writing 1 copy in a degraded state
osd_pool_default_pg_num = 256
osd_pool_default_pgp_num = 256
osd_crush_chooseleaf_type = 1
osd_scrub_load_threshold = 0.01
osd_scrub_min_interval = 137438953472
osd_scrub_max_interval = 137438953472
osd_deep_scrub_interval = 137438953472
osd_max_scrubs = 16
osd_op_threads = 8
osd_max_backfills = 1
osd_recovery_max_active = 1
osd_recovery_op_priority = 1




debug_lockdep = 0/0
debug_context = 0/0
debug_crush = 0/0
debug_buffer = 0/0
debug_timer = 0/0
debug_filer = 0/0
debug_objecter = 0/0
debug_rados = 0/0
debug_rbd = 0/0
debug_journaler = 0/0
debug_objectcatcher = 0/0
debug_client = 0/0
debug_osd = 0/0
debug_optracker = 0/0
debug_objclass = 0/0
debug_filestore = 0/0
debug_journal = 0/0
debug_ms = 0/0
debug_monc = 0/0
debug_tp = 0/0
debug_auth = 0/0
debug_finisher = 0/0
debug_heartbeatmap = 0/0
debug_perfcounter = 0/0
debug_asok = 0/0
debug_throttle = 0/0
debug_mon = 0/0
debug_paxos = 0/0
debug_rgw = 0/0


[mon]
mon_allow_pool_delete = true

[osd]
osd_heartbeat_grace = 20
osd_heartbeat_interval = 5
bluestore_block_db_size = 16106127360
bluestore_block_wal_size = 1073741824

[osd.6]
host = osd01
osd_journal =
/dev/disk/by-parttypeuuid/4fbd7e29-9d25-41b8-afd0-062c0ceff05d.1d58775a-5019-42ea-8149-a126f51a2501
crush_location = root=ssds host=osd01-ssd

[osd.7]
host = osd02
osd_journal =
/dev/disk/by-parttypeuuid/4fbd7e29-9d25-41b8-afd0-062c0ceff05d.683dc52d-5d69-4ff0-b5d9-b17056a55681
crush_location = root=ssds host=osd02-ssd

[osd.8]
host = osd04
osd_journal =
/dev/disk/by-parttypeuuid/4fbd7e29-9d25-41b8-afd0-062c0ceff05d.bd7c0088-b724-441e-9b88-9457305c541d
crush_location = root=ssds host=osd04-ssd


On 22 January 2018 at 11:29, Steven Vacaroaia  wrote:

> Hi David,
>
> Yes, I meant no separate partitions for WAL and DB
>
> I am using 2 x 10 GB bonded ( BONDING_OPTS="mode=4 miimon=100
> xmit_hash_policy=1 lacp_rate=1")  for cluster and 1 x 1GB for public
> Disks are
> Vendor Id  : TOSHIBA
> Product Id : PX05SMB040Y
> State  : Online
> Disk Type  : SAS,Solid State Device
> Capacity   : 372.0 GB
>
>
> On 22 January 2018 at 11:24, David Turner  wrote:
>
>> Disk models, other hardware information including CPU, network config?
>> You say you're using Luminous, but

Re: [ceph-users] Luminous - bad performance

2018-01-22 Thread Steven Vacaroaia
Hi David,

Yes, I meant no separate partitions for WAL and DB

I am using 2 x 10 GB bonded ( BONDING_OPTS="mode=4 miimon=100
xmit_hash_policy=1 lacp_rate=1")  for cluster and 1 x 1GB for public
Disks are
Vendor Id  : TOSHIBA
Product Id : PX05SMB040Y
State  : Online
Disk Type  : SAS,Solid State Device
Capacity   : 372.0 GB


On 22 January 2018 at 11:24, David Turner  wrote:

> Disk models, other hardware information including CPU, network config?
> You say you're using Luminous, but then say journal on same device.  I'm
> assuming you mean that you just have the bluestore OSD configured without a
> separate WAL or DB partition?  Any more specifics you can give will be
> helpful.
>
> On Mon, Jan 22, 2018 at 11:20 AM Steven Vacaroaia 
> wrote:
>
>> Hi,
>>
>> I'll appreciate if you can provide some guidance / suggestions regarding
>> perfomance issues on a test cluster ( 3 x DELL R620, 1 Entreprise SSD, 3 x
>> 600 GB ,Entreprise HDD, 8 cores, 64 GB RAM)
>>
>> I created 2 pools ( replication factor 2) one with only SSD and the other
>> with only HDD
>> ( journal on same disk for both)
>>
>> The perfomance is quite similar although I was expecting to be at least 5
>> times better
>> No issues noticed using atop
>>
>> What  should I check / tune ?
>>
>> Many thanks
>> Steven
>>
>>
>>
>> HDD based pool ( journal on the same disk)
>>
>> ceph osd pool get scbench256 all
>>
>> size: 2
>> min_size: 1
>> crash_replay_interval: 0
>> pg_num: 256
>> pgp_num: 256
>> crush_rule: replicated_rule
>> hashpspool: true
>> nodelete: false
>> nopgchange: false
>> nosizechange: false
>> write_fadvise_dontneed: false
>> noscrub: false
>> nodeep-scrub: false
>> use_gmt_hitset: 1
>> auid: 0
>> fast_read: 0
>>
>>
>> rbd bench --io-type write  image1 --pool=scbench256
>> bench  type write io_size 4096 io_threads 16 bytes 1073741824 pattern
>> sequential
>>   SEC   OPS   OPS/SEC   BYTES/SEC
>> 1 46816  46836.46  191842139.78
>> 2 90658  45339.11  185709011.80
>> 3133671  44540.80  182439126.08
>> 4177341  44340.36  181618100.14
>> 5217300  43464.04  178028704.54
>> 6259595  42555.85  174308767.05
>> elapsed: 6  ops:   262144  ops/sec: 42694.50  bytes/sec: 174876688.23
>>
>> fio /home/cephuser/write_256.fio
>> write-4M: (g=0): rw=randread, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd,
>> iodepth=32
>> fio-2.2.8
>> Starting 1 process
>> rbd engine: RBD version: 1.12.0
>> Jobs: 1 (f=1): [r(1)] [100.0% done] [66284KB/0KB/0KB /s] [16.6K/0/0 iops]
>> [eta 00m:00s]
>>
>>
>> fio /home/cephuser/write_256.fio
>> write-4M: (g=0): rw=write, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
>> fio-2.2.8
>> Starting 1 process
>> rbd engine: RBD version: 1.12.0
>> Jobs: 1 (f=1): [W(1)] [100.0% done] [0KB/14464KB/0KB /s] [0/3616/0 iops]
>> [eta 00m:00s]
>>
>>
>> SSD based pool
>>
>>
>> ceph osd pool get ssdpool all
>>
>> size: 2
>> min_size: 1
>> crash_replay_interval: 0
>> pg_num: 128
>> pgp_num: 128
>> crush_rule: ssdpool
>> hashpspool: true
>> nodelete: false
>> nopgchange: false
>> nosizechange: false
>> write_fadvise_dontneed: false
>> noscrub: false
>> nodeep-scrub: false
>> use_gmt_hitset: 1
>> auid: 0
>> fast_read: 0
>>
>>  rbd -p ssdpool create --size 52100 image2
>>
>> rbd bench --io-type write  image2 --pool=ssdpool
>> bench  type write io_size 4096 io_threads 16 bytes 1073741824 pattern
>> sequential
>>   SEC   OPS   OPS/SEC   BYTES/SEC
>> 1 42412  41867.57  171489557.93
>> 2 78343  39180.86  160484805.88
>> 3118082  39076.48  160057256.16
>> 4155164  38683.98  158449572.38
>> 5192825  38307.59  156907885.84
>> 6230701  37716.95  154488608.16
>> elapsed: 7  ops:   262144  ops/sec: 36862.89  bytes/sec: 150990387.29
>>
>>
>> [root@osd01 ~]# fio /home/cephuser/write_256.fio
>> write-4M: (g=0): rw=write, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
>> fio-2.2.8
>> Starting 1 process
>> rbd engine: RBD version: 1.12.0
>> Jobs: 1 (f=1): [W(1)] [100.0% done] [0KB/20224KB/0KB /s] [0/5056/0 iops]
>> [eta 00m:00s]
>>
>>
>> fio /home/cephuser/write_256.fio
>> write-4M: (g=0): rw=randread, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd,
>> iodepth=32
>> fio-2.2.8
>> Starting 1 process
>> rbd engine: RBD version: 1.12.0
>> Jobs: 1 (f=1): [r(1)] [100.0% done] [76096KB/0KB/0KB /s] [19.3K/0/0 iops]
>> [eta 00m:00s]
>> ___
>> ceph-users mailing list
>> ceph-users@lists.ceph.com
>> http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
>>
>
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com


Re: [ceph-users] Luminous - bad performance

2018-01-22 Thread Sage Weil
On Mon, 22 Jan 2018, Steven Vacaroaia wrote:
> Hi,
> 
> I'll appreciate if you can provide some guidance / suggestions regarding
> perfomance issues on a test cluster ( 3 x DELL R620, 1 Entreprise SSD, 3 x
> 600 GB ,Entreprise HDD, 8 cores, 64 GB RAM)
> 
> I created 2 pools ( replication factor 2) one with only SSD and the other
> with only HDD
> ( journal on same disk for both)
> 
> The perfomance is quite similar although I was expecting to be at least 5
> times better
> No issues noticed using atop
> 
> What  should I check / tune ?

Can you test both pools with 'rados bench' instead of 'rbd bench'?  The 
bottleneck might be in RBD (e.g., in the object map updates).

sage


> 
> Many thanks
> Steven
> 
> 
> 
> HDD based pool ( journal on the same disk)
> 
> ceph osd pool get scbench256 all
> 
> size: 2
> min_size: 1
> crash_replay_interval: 0
> pg_num: 256
> pgp_num: 256
> crush_rule: replicated_rule
> hashpspool: true
> nodelete: false
> nopgchange: false
> nosizechange: false
> write_fadvise_dontneed: false
> noscrub: false
> nodeep-scrub: false
> use_gmt_hitset: 1
> auid: 0
> fast_read: 0
> 
> 
> rbd bench --io-type write  image1 --pool=scbench256
> bench  type write io_size 4096 io_threads 16 bytes 1073741824 pattern
> sequential
>   SEC   OPS   OPS/SEC   BYTES/SEC
> 1 46816  46836.46  191842139.78
> 2 90658  45339.11  185709011.80
> 3133671  44540.80  182439126.08
> 4177341  44340.36  181618100.14
> 5217300  43464.04  178028704.54
> 6259595  42555.85  174308767.05
> elapsed: 6  ops:   262144  ops/sec: 42694.50  bytes/sec: 174876688.23
> 
> fio /home/cephuser/write_256.fio
> write-4M: (g=0): rw=randread, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
> fio-2.2.8
> Starting 1 process
> rbd engine: RBD version: 1.12.0
> Jobs: 1 (f=1): [r(1)] [100.0% done] [66284KB/0KB/0KB /s] [16.6K/0/0 iops]
> [eta 00m:00s]
> 
> 
> fio /home/cephuser/write_256.fio
> write-4M: (g=0): rw=write, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
> fio-2.2.8
> Starting 1 process
> rbd engine: RBD version: 1.12.0
> Jobs: 1 (f=1): [W(1)] [100.0% done] [0KB/14464KB/0KB /s] [0/3616/0 iops]
> [eta 00m:00s]
> 
> 
> SSD based pool
> 
> 
> ceph osd pool get ssdpool all
> 
> size: 2
> min_size: 1
> crash_replay_interval: 0
> pg_num: 128
> pgp_num: 128
> crush_rule: ssdpool
> hashpspool: true
> nodelete: false
> nopgchange: false
> nosizechange: false
> write_fadvise_dontneed: false
> noscrub: false
> nodeep-scrub: false
> use_gmt_hitset: 1
> auid: 0
> fast_read: 0
> 
>  rbd -p ssdpool create --size 52100 image2
> 
> rbd bench --io-type write  image2 --pool=ssdpool
> bench  type write io_size 4096 io_threads 16 bytes 1073741824 pattern
> sequential
>   SEC   OPS   OPS/SEC   BYTES/SEC
> 1 42412  41867.57  171489557.93
> 2 78343  39180.86  160484805.88
> 3118082  39076.48  160057256.16
> 4155164  38683.98  158449572.38
> 5192825  38307.59  156907885.84
> 6230701  37716.95  154488608.16
> elapsed: 7  ops:   262144  ops/sec: 36862.89  bytes/sec: 150990387.29
> 
> 
> [root@osd01 ~]# fio /home/cephuser/write_256.fio
> write-4M: (g=0): rw=write, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
> fio-2.2.8
> Starting 1 process
> rbd engine: RBD version: 1.12.0
> Jobs: 1 (f=1): [W(1)] [100.0% done] [0KB/20224KB/0KB /s] [0/5056/0 iops]
> [eta 00m:00s]
> 
> 
> fio /home/cephuser/write_256.fio
> write-4M: (g=0): rw=randread, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
> fio-2.2.8
> Starting 1 process
> rbd engine: RBD version: 1.12.0
> Jobs: 1 (f=1): [r(1)] [100.0% done] [76096KB/0KB/0KB /s] [19.3K/0/0 iops]
> [eta 00m:00s]
> 
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com


Re: [ceph-users] Luminous - bad performance

2018-01-22 Thread David Turner
Disk models, other hardware information including CPU, network config?  You
say you're using Luminous, but then say journal on same device.  I'm
assuming you mean that you just have the bluestore OSD configured without a
separate WAL or DB partition?  Any more specifics you can give will be
helpful.

On Mon, Jan 22, 2018 at 11:20 AM Steven Vacaroaia  wrote:

> Hi,
>
> I'll appreciate if you can provide some guidance / suggestions regarding
> perfomance issues on a test cluster ( 3 x DELL R620, 1 Entreprise SSD, 3 x
> 600 GB ,Entreprise HDD, 8 cores, 64 GB RAM)
>
> I created 2 pools ( replication factor 2) one with only SSD and the other
> with only HDD
> ( journal on same disk for both)
>
> The perfomance is quite similar although I was expecting to be at least 5
> times better
> No issues noticed using atop
>
> What  should I check / tune ?
>
> Many thanks
> Steven
>
>
>
> HDD based pool ( journal on the same disk)
>
> ceph osd pool get scbench256 all
>
> size: 2
> min_size: 1
> crash_replay_interval: 0
> pg_num: 256
> pgp_num: 256
> crush_rule: replicated_rule
> hashpspool: true
> nodelete: false
> nopgchange: false
> nosizechange: false
> write_fadvise_dontneed: false
> noscrub: false
> nodeep-scrub: false
> use_gmt_hitset: 1
> auid: 0
> fast_read: 0
>
>
> rbd bench --io-type write  image1 --pool=scbench256
> bench  type write io_size 4096 io_threads 16 bytes 1073741824 pattern
> sequential
>   SEC   OPS   OPS/SEC   BYTES/SEC
> 1 46816  46836.46  191842139.78
> 2 90658  45339.11  185709011.80
> 3133671  44540.80  182439126.08
> 4177341  44340.36  181618100.14
> 5217300  43464.04  178028704.54
> 6259595  42555.85  174308767.05
> elapsed: 6  ops:   262144  ops/sec: 42694.50  bytes/sec: 174876688.23
>
> fio /home/cephuser/write_256.fio
> write-4M: (g=0): rw=randread, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd,
> iodepth=32
> fio-2.2.8
> Starting 1 process
> rbd engine: RBD version: 1.12.0
> Jobs: 1 (f=1): [r(1)] [100.0% done] [66284KB/0KB/0KB /s] [16.6K/0/0 iops]
> [eta 00m:00s]
>
>
> fio /home/cephuser/write_256.fio
> write-4M: (g=0): rw=write, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
> fio-2.2.8
> Starting 1 process
> rbd engine: RBD version: 1.12.0
> Jobs: 1 (f=1): [W(1)] [100.0% done] [0KB/14464KB/0KB /s] [0/3616/0 iops]
> [eta 00m:00s]
>
>
> SSD based pool
>
>
> ceph osd pool get ssdpool all
>
> size: 2
> min_size: 1
> crash_replay_interval: 0
> pg_num: 128
> pgp_num: 128
> crush_rule: ssdpool
> hashpspool: true
> nodelete: false
> nopgchange: false
> nosizechange: false
> write_fadvise_dontneed: false
> noscrub: false
> nodeep-scrub: false
> use_gmt_hitset: 1
> auid: 0
> fast_read: 0
>
>  rbd -p ssdpool create --size 52100 image2
>
> rbd bench --io-type write  image2 --pool=ssdpool
> bench  type write io_size 4096 io_threads 16 bytes 1073741824 pattern
> sequential
>   SEC   OPS   OPS/SEC   BYTES/SEC
> 1 42412  41867.57  171489557.93
> 2 78343  39180.86  160484805.88
> 3118082  39076.48  160057256.16
> 4155164  38683.98  158449572.38
> 5192825  38307.59  156907885.84
> 6230701  37716.95  154488608.16
> elapsed: 7  ops:   262144  ops/sec: 36862.89  bytes/sec: 150990387.29
>
>
> [root@osd01 ~]# fio /home/cephuser/write_256.fio
> write-4M: (g=0): rw=write, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
> fio-2.2.8
> Starting 1 process
> rbd engine: RBD version: 1.12.0
> Jobs: 1 (f=1): [W(1)] [100.0% done] [0KB/20224KB/0KB /s] [0/5056/0 iops]
> [eta 00m:00s]
>
>
> fio /home/cephuser/write_256.fio
> write-4M: (g=0): rw=randread, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd,
> iodepth=32
> fio-2.2.8
> Starting 1 process
> rbd engine: RBD version: 1.12.0
> Jobs: 1 (f=1): [r(1)] [100.0% done] [76096KB/0KB/0KB /s] [19.3K/0/0 iops]
> [eta 00m:00s]
> ___
> ceph-users mailing list
> ceph-users@lists.ceph.com
> http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
>
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com


[ceph-users] Luminous - bad performance

2018-01-22 Thread Steven Vacaroaia
Hi,

I'll appreciate if you can provide some guidance / suggestions regarding
perfomance issues on a test cluster ( 3 x DELL R620, 1 Entreprise SSD, 3 x
600 GB ,Entreprise HDD, 8 cores, 64 GB RAM)

I created 2 pools ( replication factor 2) one with only SSD and the other
with only HDD
( journal on same disk for both)

The perfomance is quite similar although I was expecting to be at least 5
times better
No issues noticed using atop

What  should I check / tune ?

Many thanks
Steven



HDD based pool ( journal on the same disk)

ceph osd pool get scbench256 all

size: 2
min_size: 1
crash_replay_interval: 0
pg_num: 256
pgp_num: 256
crush_rule: replicated_rule
hashpspool: true
nodelete: false
nopgchange: false
nosizechange: false
write_fadvise_dontneed: false
noscrub: false
nodeep-scrub: false
use_gmt_hitset: 1
auid: 0
fast_read: 0


rbd bench --io-type write  image1 --pool=scbench256
bench  type write io_size 4096 io_threads 16 bytes 1073741824 pattern
sequential
  SEC   OPS   OPS/SEC   BYTES/SEC
1 46816  46836.46  191842139.78
2 90658  45339.11  185709011.80
3133671  44540.80  182439126.08
4177341  44340.36  181618100.14
5217300  43464.04  178028704.54
6259595  42555.85  174308767.05
elapsed: 6  ops:   262144  ops/sec: 42694.50  bytes/sec: 174876688.23

fio /home/cephuser/write_256.fio
write-4M: (g=0): rw=randread, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
fio-2.2.8
Starting 1 process
rbd engine: RBD version: 1.12.0
Jobs: 1 (f=1): [r(1)] [100.0% done] [66284KB/0KB/0KB /s] [16.6K/0/0 iops]
[eta 00m:00s]


fio /home/cephuser/write_256.fio
write-4M: (g=0): rw=write, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
fio-2.2.8
Starting 1 process
rbd engine: RBD version: 1.12.0
Jobs: 1 (f=1): [W(1)] [100.0% done] [0KB/14464KB/0KB /s] [0/3616/0 iops]
[eta 00m:00s]


SSD based pool


ceph osd pool get ssdpool all

size: 2
min_size: 1
crash_replay_interval: 0
pg_num: 128
pgp_num: 128
crush_rule: ssdpool
hashpspool: true
nodelete: false
nopgchange: false
nosizechange: false
write_fadvise_dontneed: false
noscrub: false
nodeep-scrub: false
use_gmt_hitset: 1
auid: 0
fast_read: 0

 rbd -p ssdpool create --size 52100 image2

rbd bench --io-type write  image2 --pool=ssdpool
bench  type write io_size 4096 io_threads 16 bytes 1073741824 pattern
sequential
  SEC   OPS   OPS/SEC   BYTES/SEC
1 42412  41867.57  171489557.93
2 78343  39180.86  160484805.88
3118082  39076.48  160057256.16
4155164  38683.98  158449572.38
5192825  38307.59  156907885.84
6230701  37716.95  154488608.16
elapsed: 7  ops:   262144  ops/sec: 36862.89  bytes/sec: 150990387.29


[root@osd01 ~]# fio /home/cephuser/write_256.fio
write-4M: (g=0): rw=write, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
fio-2.2.8
Starting 1 process
rbd engine: RBD version: 1.12.0
Jobs: 1 (f=1): [W(1)] [100.0% done] [0KB/20224KB/0KB /s] [0/5056/0 iops]
[eta 00m:00s]


fio /home/cephuser/write_256.fio
write-4M: (g=0): rw=randread, bs=4K-4K/4K-4K/4K-4K, ioengine=rbd, iodepth=32
fio-2.2.8
Starting 1 process
rbd engine: RBD version: 1.12.0
Jobs: 1 (f=1): [r(1)] [100.0% done] [76096KB/0KB/0KB /s] [19.3K/0/0 iops]
[eta 00m:00s]
___
ceph-users mailing list
ceph-users@lists.ceph.com