Re: [c-nsp] help cisco product
In order to use the IF /0 and /1 as 1000BaseT on a 5510, you need the Security Plus License as well as a ASA Release of minimum 7.2(3) iirc. See here: http://www.cisco.com/en/US/docs/security/asa/asa72/release/notes/asarn723.html regards from Berlin Jens Neu Health Services Network Administration Phone: +49 (0) 30 68905-2412 Mail: jens@biotronik.de From: Deric Kwok deric.kwok2...@gmail.com To: Cisco Network Service Providers cisco-nsp@puck.nether.net Date: 01/25/2011 04:28 PM Subject: [c-nsp] help cisco product Sent by: cisco-nsp-boun...@puck.nether.net Hi I am new in cisco product I brought new ASA551 from reseller in Asia but not my country Now we discover that the product is not same as we saw in the reseller website In the web, the product includes 2FE and 3 x 100M but now it is all 100M The reseller claims the version and the serial no. should includes 2GigE but we can get ios to sh int as Ethernet (100M) NOT any GE Try to configure int and it only shows 10M / 100M and auto selection too The box is also showing S EC-BUN-K9. 1/ How can we get cisco to help? 2/ I register to cisco website. I am in guess account. Can I get support? 3/ ls cisco shipping the wrong box? 4/ ls reseller correct? Serial no. can prove the product. How can we check with cisco? Thank you for your help ___ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/ www.biotronik.com BIOTRONIK SE Co. KG Woermannkehre 1, 12359 Berlin, Germany Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRA 6501 Vertreten durch ihre Komplementärin: BIOTRONIK MT SE Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRB 118866 B Geschäftsführende Direktoren: Christoph Böhmer, Dr. Werner Braun, Dr. Lothar Krings BIOTRONIK - A global manufacturer of advanced Cardiac Rhythm Management systems and Vascular Intervention devices. Quality, innovation, and reliability define BIOTRONIK and our growing success. We are innovators of technologies like the first wireless remote monitoring system - Home Monitoring®, Closed Loop Stimulation and coveted lead solutions as well as state-of-the-art stents, balloons and guide wires for coronary and peripheral indications. We highly invest in the development of drug eluting devices and are leading the industry with our drug eluting absorbable metal scaffold program. This e-mail and the information it contains including attachments are confidential and meant only for use by the intended recipient(s); disclosure or copying is strictly prohibited. If you are not addressed, but in the possession of this e-mail, please notify the sender immediately and delete the document. ___ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/
Re: [c-nsp] How to limit bandwidth on CISCO switch interfaces
You are probalby looking for this: http://www.cisco.com/en/US/docs/switches/lan/catalyst2960/software/release/12.2_25_see/configuration/guide/swqos.html#wp1253412 regards Jens Neu Health Services Network Administration Phone: +49 (0) 30 68905-2412 Mail: jens@biotronik.de From: JA Colmenares sforc...@yahoo.com To: Cisco NSP Forum cisco-nsp@puck.nether.net Date: 01/06/2011 06:00 AM Subject: [c-nsp] How to limit bandwidth on CISCO switch interfaces Sent by: cisco-nsp-boun...@puck.nether.net I need to limit bandwidth on the trunk ports of two connected switches(2960 to 3750). It is currently transmitting at 100 mbps and I want to limit it to 50 mbps How can this be done? can anyone provide any steps or resources to get this done. Thanks Juan ___ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/ www.biotronik.com BIOTRONIK SE Co. KG Woermannkehre 1, 12359 Berlin, Germany Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRA 6501 Vertreten durch ihre Komplementärin: BIOTRONIK MT SE Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRB 118866 B Geschäftsführende Direktoren: Christoph Böhmer, Dr. Werner Braun, Dr. Lothar Krings BIOTRONIK - A global manufacturer of advanced Cardiac Rhythm Management systems and Vascular Intervention devices. Quality, innovation, and reliability define BIOTRONIK and our growing success. We are innovators of technologies like the first wireless remote monitoring system - Home Monitoring®, Closed Loop Stimulation and coveted lead solutions as well as state-of-the-art stents, balloons and guide wires for coronary and peripheral indications. We highly invest in the development of drug eluting devices and are leading the industry with our drug eluting absorbable metal scaffold program. This e-mail and the information it contains including attachments are confidential and meant only for use by the intended recipient(s); disclosure or copying is strictly prohibited. If you are not addressed, but in the possession of this e-mail, please notify the sender immediately and delete the document. ___ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/
Re: [c-nsp] cisco-nsp Digest, Vol 87, Issue 93
Peter, thanks a lot! best regards from Berlin Jens Neu Health Services Network Administration Phone: +49 (0) 30 68905-2412 Mail: jens@biotronik.de Peter Haag peter.h...@switch.ch 03/01/2010 08:13 AM Please respond to peter.h...@switch.ch To peter.h...@switch.ch cc cisco-nsp@puck.nether.net, Jens Neu jens@biotronik.com Subject Re: cisco-nsp Digest, Vol 87, Issue 93 -BEGIN PGP SIGNED MESSAGE- Hash: SHA1 Hi Jens, The time window in the summary lines includes all flows in the flow file not only those passed the filter. It should actually be limited to the filtered flows. However, it does not explain, why you see flows ending in the future. I'll fix the time window issue. - Peter Peter Haag wrote: Hi Jens, I will look into that. - Peter Dear all, I've encountered a strange behavior of nfdump when running it with the -s and -t options. Sometimes it works as expected, sometimes it gives me strange values in Time window:, e.g. Time window: 2010-01-01 00:00:22 - 2010-03-13 04:34:32 when running with -t 2010/01/01.00:00:00-2010/01/31.00:00:00 details see: http://paste.debian.net/61554/ what could be the explanation? NTP issues on the router, or qualifies for a bug report? best regards Jens Neu Health Services Network Administration Phone: +49 (0) 30 68905-2412 Mail: jens@biotronik.de -- ___ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp End of cisco-nsp Digest, Vol 87, Issue 93 * - -- ___ SWITCH - The Swiss Education and Research Network __ Peter Haag, Security Engineer, Member of SWITCH CERT PGP fingerprint: D9 31 D5 83 03 95 68 BA FB 84 CA 94 AB FC 5D D7 SWITCH, Werdstrasse 2, P.O. Box, CH-8021 Zurich, Switzerland E-mail: peter.h...@switch.ch Web: http://www.switch.ch/ -BEGIN PGP SIGNATURE- Version: GnuPG v1.4.5 (Darwin) iQCVAwUBS4to8P5AbZRALNr/AQL7mAP9E8giNLkq1S012c7RdiyL4OcCIHbWUMEE WaXyZJ/C4Fg30dUhipZ+AWnmy0W5j10QZzmMSQWH2N5w4F3GIpQPon/jHpMnixx+ zR3HJ2hstCOkDIx2As7+1ym51UTxtqrwpsAO8F1MSUj7pgaGIriebzbtGzCaLs/U V7zNjaLWvc4= =d2fd -END PGP SIGNATURE- ___ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/
[c-nsp] Strange Time window when running nfdump
Dear all, I've encountered a strange behavior of nfdump when running it with the -s and -t options. Sometimes it works as expected, sometimes it gives me strange values in Time window:, e.g. Time window: 2010-01-01 00:00:22 - 2010-03-13 04:34:32 when running with -t 2010/01/01.00:00:00-2010/01/31.00:00:00 details see: http://paste.debian.net/61554/ what could be the explanation? NTP issues on the router, or qualifies for a bug report? best regards Jens Neu Health Services Network Administration Phone: +49 (0) 30 68905-2412 Mail: jens@biotronik.de ___ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/
Re: [c-nsp] ACLs and 2948G-L3
Hm thanks, I think I'm going to need two GBICs then. Jens Neu Health Services Network Administration Phone: +49 (0) 30 68905-2412 Mail: jens@biotronik.de Asbjorn Hojmark - Lists li...@hojmark.org 01/07/2010 05:44 PM To Jens Neu jens@biotronik.com cc cisco-nsp@puck.nether.net Subject Re: [c-nsp] ACLs and 2948G-L3 On Thu, 7 Jan 2010 16:37:29 +0100, you wrote: I've come across a lot of people complaining about the 2948G-L3 and access-lists. I defined two extended access-lists which are bound to FastEthernet35 (in and out). The switch complains nowhere, but when the ACLs should trigger, this appears in the log: ACLs are only supported on the GE interfaces, not FE. -A www.biotronik.com BIOTRONIK SE Co. KG Woermannkehre 1, 12359 Berlin, Germany Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRA 6501 Vertreten durch ihre Komplementärin: BIOTRONIK MT SE Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRB 118866 B Vorsitzender des Verwaltungsrats: Dr. Max Schaldach Geschäftsführende Direktoren: Christoph Böhmer, Dr. Werner Braun, Dr. Lothar Krings BIOTRONIK - A global manufacturer of advanced Cardiac Rhythm Management systems and Vascular Intervention devices. Quality, innovation, and reliability define BIOTRONIK and our growing success. We are innovators of technologies like the first wireless remote monitoring system - Home Monitoring®, Closed Loop Stimulation and coveted lead solutions as well as state-of-the-art stents, balloons and guide wires for coronary and peripheral indications. We highly invest in the development of drug eluting devices and are leading the industry with our bioabsorbable metal stent program. This e-mail and the information it contains including attachments are confidential and meant only for use by the intended recipient(s); disclosure or copying is strictly prohibited. If you are not addressed, but in the possession of this e-mail, please notify the sender immediately and delete the document. ___ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/
[c-nsp] PXE not working on Cat2948
Der all, I have a Catalyst 2948G which seems to keep PXE boot from working properly. This one Cat2948 is the only Layer 2 device between the DHCP/PXE boot server and the PXE client - both are directly connected and share a /24. PXE boot is not working at all, and DHCP is unbearably slow, for no apparent reason. Both PXE Server and Client(s) are various IBM xSeries using the onboard GBit interfaces. Now the fun stuff: when I put a second Layer 2 device between the Cat 2948 and the PXE client, it is magically working. Means: PXE Server - Cat 2948 - some cheap Netgear Office switch - PXE Client == works. In fact, any additional Layer 2 device that appears between PXE Client and the Cat 2948 scares the problem away. Anyone seen this before? Any hints where to start looking? The switch looks as follows: WS-C2948 Software, Version NmpSW: 8.4(11)GLX Copyright (c) 1995-2006 by Cisco Systems, Inc. NMP S/W compiled on Apr 27 2006, 12:46:44 GSP S/W compiled on Apr 27 2006, 11:47:52 System Bootstrap Version: 6.1(4) Hardware Version: 2.5 Model: WS-C2948 Serial #: JAE061500JB Mod Port Model Serial # Versions --- -- - 1 0WS-X2948 JAE061500JB Hw : 2.5 Gsp: 8.4(11.0) Nmp: 8.4(11)GLX 2 50 WS-C2948G JAE061500JB Hw : 2.5 DRAMFLASH NVRAM Module Total UsedFreeTotal UsedFreeTotal Used Free -- --- --- --- --- --- --- - - - 1 65536K 37349K 28187K 12288K 10648K 1640K 480K 85K 395K best regards! Jens Neu Phone: +49 (0) 30 68905-2412 Mail: jens@biotronik.de www.biotronik.com BIOTRONIK SE Co. KG Woermannkehre 1, 12359 Berlin, Germany Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRA 6501 Vertreten durch ihre Komplementärin: BIOTRONIK MT SE Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRB 118866 B Vorsitzender des Verwaltungsrats: Dr. Max Schaldach Geschäftsführende Direktoren: Christoph Böhmer, Dr. Werner Braun, Dr. Lothar Krings BIOTRONIK - A global manufacturer of advanced Cardiac Rhythm Management systems and Vascular Intervention devices. Quality, innovation, and reliability define BIOTRONIK and our growing success. We are innovators of technologies like the first wireless remote monitoring system - Home Monitoring®, Closed Loop Stimulation and coveted lead solutions as well as state-of-the-art stents, balloons and guide wires for coronary and peripheral indications. We highly invest in the development of drug eluting devices and are leading the industry with our bioabsorbable metal stent program. This e-mail and the information it contains including attachments are confidential and meant only for use by the intended recipient(s); disclosure or copying is strictly prohibited. If you are not addressed, but in the possession of this e-mail, please notify the sender immediately and delete the document. ___ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/
Re: [c-nsp] PXE not working on Cat2948
spanning-tree portfast Thank you all, I'm going to update my STP knowledge :) regards Jens Neu Phone: +49 (0) 30 68905-2412 Mail: jens@biotronik.de Gert Doering g...@greenie.muc.de 01/08/2010 02:26 PM To Jens Neu jens@biotronik.com cc cisco-nsp@puck.nether.net Subject Re: [c-nsp] PXE not working on Cat2948 Hi, On Fri, Jan 08, 2010 at 02:04:05PM +0100, Jens Neu wrote: Anyone seen this before? Any hints where to start looking? spanning-tree portfast gert -- USENET is *not* the non-clickable part of WWW! //www.muc.de/~gert/ Gert Doering - Munich, Germany g...@greenie.muc.de fax: +49-89-35655025 g...@net.informatik.tu-muenchen.de www.biotronik.com BIOTRONIK SE Co. KG Woermannkehre 1, 12359 Berlin, Germany Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRA 6501 Vertreten durch ihre Komplementärin: BIOTRONIK MT SE Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRB 118866 B Vorsitzender des Verwaltungsrats: Dr. Max Schaldach Geschäftsführende Direktoren: Christoph Böhmer, Dr. Werner Braun, Dr. Lothar Krings BIOTRONIK - A global manufacturer of advanced Cardiac Rhythm Management systems and Vascular Intervention devices. Quality, innovation, and reliability define BIOTRONIK and our growing success. We are innovators of technologies like the first wireless remote monitoring system - Home Monitoring®, Closed Loop Stimulation and coveted lead solutions as well as state-of-the-art stents, balloons and guide wires for coronary and peripheral indications. We highly invest in the development of drug eluting devices and are leading the industry with our bioabsorbable metal stent program. This e-mail and the information it contains including attachments are confidential and meant only for use by the intended recipient(s); disclosure or copying is strictly prohibited. If you are not addressed, but in the possession of this e-mail, please notify the sender immediately and delete the document. ___ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/
[c-nsp] ACLs and 2948G-L3
Dear all, I've come across a lot of people complaining about the 2948G-L3 and access-lists. I defined two extended access-lists which are bound to FastEthernet35 (in and out). The switch complains nowhere, but when the ACLs should trigger, this appears in the log: Jan 6 16:03:57 172.16.15.250 13651: Jan 6 15:03:56.983 UTC: ACL card not present for interface FastEthernet35 Jan 6 16:04:05 172.16.15.250 13652: Jan 6 15:04:04.296 UTC: ACL card not present for interface FastEthernet35 I'm running SW 12.0(25)W5(27d) on the device, while http://www.cisco.com/cgi-bin/tablebuild.pl/cat2948g-l3 tells me this is the most recent one. Can anyone enlighten me what this ACL card is about? Is there a way to use ACLs on the device at all? thanks and best regards! Jens Neu www.biotronik.com BIOTRONIK SE Co. KG Woermannkehre 1, 12359 Berlin, Germany Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRA 6501 Vertreten durch ihre Komplementärin: BIOTRONIK MT SE Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRB 118866 B Vorsitzender des Verwaltungsrats: Dr. Max Schaldach Geschäftsführende Direktoren: Christoph Böhmer, Dr. Werner Braun, Dr. Lothar Krings BIOTRONIK - A global manufacturer of advanced Cardiac Rhythm Management systems and Vascular Intervention devices. Quality, innovation, and reliability define BIOTRONIK and our growing success. We are innovators of technologies like the first wireless remote monitoring system - Home Monitoring®, Closed Loop Stimulation and coveted lead solutions as well as state-of-the-art stents, balloons and guide wires for coronary and peripheral indications. We highly invest in the development of drug eluting devices and are leading the industry with our bioabsorbable metal stent program. This e-mail and the information it contains including attachments are confidential and meant only for use by the intended recipient(s); disclosure or copying is strictly prohibited. If you are not addressed, but in the possession of this e-mail, please notify the sender immediately and delete the document. ___ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/