Re: [darktable-user] Anyone know where to find a cie/it8 file for the Color Checker Passport?

2018-02-28 Thread Robert Bieber

That did it, thanks!


On 02/28/2018 02:53 AM, Tobias Ellinghaus wrote:

Am Mittwoch, 28. Februar 2018, 11:12:57 CET schrieb Tobias Ellinghaus:

Am Mittwoch, 28. Februar 2018, 04:46:26 CET schrieb Robert Bieber:

I'm curious if anyone's had any luck building a profile with dt-chart
using a cie/it8 file for the second step in the process. I've gotten it
to work successfully by using the chart file that ships with Argyll, but
if I try to use the corresponding cie file for the next step, I get an
error message "error with the IT8 file, can't find the SAMPLE_ID column."

I'm guessing that even though the option says cie/it8 file, maybe only
it8 files are well supported?  Or maybe the one that Argyll ships with
is just malformed.  Does anyone have an idea where I might find a usable
it8 file for the ColorChecker passport?  This seems like something that
should be prominently published by the manufacturer, but the only place
I was able to find cht and cie files at all was in the Argyll distribution

The file ColorCheckerPassport.cie as shipped by Argyll uses "SAMPLE_LOC"
instead of "SAMPLE_ID" to refer to the colors. Just changing the line

SAMPLE_LOC XYZ_X XYZ_Y XYZ_Z LAB_L LAB_A LAB_B

to

SAMPLE_ID XYZ_X XYZ_Y XYZ_Z LAB_L LAB_A LAB_B

made it work for me. At least darktable-chart no longer complained. That
being said, the Lab values dt-chart computes from the XYZ reference numbers
look off to me. I'll have a look.

I had a look. It seems that lcms2 fails to properly parse float numbers when
the current locale uses anything else than '.' as the decimal separator. So
please make sure to run dt-chart with LANG=C. :-(


Thanks,
Robby

Tobias



darktable user mailing list
to unsubscribe send a mail to darktable-user+unsubscr...@lists.darktable.org



Re: [darktable-user] Anyone know where to find a cie/it8 file for the Color Checker Passport?

2018-02-28 Thread Tobias Ellinghaus
Am Mittwoch, 28. Februar 2018, 11:12:57 CET schrieb Tobias Ellinghaus:
> Am Mittwoch, 28. Februar 2018, 04:46:26 CET schrieb Robert Bieber:
> > I'm curious if anyone's had any luck building a profile with dt-chart
> > using a cie/it8 file for the second step in the process. I've gotten it
> > to work successfully by using the chart file that ships with Argyll, but
> > if I try to use the corresponding cie file for the next step, I get an
> > error message "error with the IT8 file, can't find the SAMPLE_ID column."
> > 
> > I'm guessing that even though the option says cie/it8 file, maybe only
> > it8 files are well supported?  Or maybe the one that Argyll ships with
> > is just malformed.  Does anyone have an idea where I might find a usable
> > it8 file for the ColorChecker passport?  This seems like something that
> > should be prominently published by the manufacturer, but the only place
> > I was able to find cht and cie files at all was in the Argyll distribution
> 
> The file ColorCheckerPassport.cie as shipped by Argyll uses "SAMPLE_LOC"
> instead of "SAMPLE_ID" to refer to the colors. Just changing the line
> 
> SAMPLE_LOC XYZ_X XYZ_Y XYZ_Z LAB_L LAB_A LAB_B
> 
> to
> 
> SAMPLE_ID XYZ_X XYZ_Y XYZ_Z LAB_L LAB_A LAB_B
> 
> made it work for me. At least darktable-chart no longer complained. That
> being said, the Lab values dt-chart computes from the XYZ reference numbers
> look off to me. I'll have a look.

I had a look. It seems that lcms2 fails to properly parse float numbers when 
the current locale uses anything else than '.' as the decimal separator. So 
please make sure to run dt-chart with LANG=C. :-(

> > Thanks,
> > Robby
> 
> Tobias



signature.asc
Description: This is a digitally signed message part.


Re: [darktable-user] Anyone know where to find a cie/it8 file for the Color Checker Passport?

2018-02-28 Thread Tobias Ellinghaus
Am Mittwoch, 28. Februar 2018, 04:46:26 CET schrieb Robert Bieber:
> I'm curious if anyone's had any luck building a profile with dt-chart
> using a cie/it8 file for the second step in the process. I've gotten it
> to work successfully by using the chart file that ships with Argyll, but
> if I try to use the corresponding cie file for the next step, I get an
> error message "error with the IT8 file, can't find the SAMPLE_ID column."
> 
> I'm guessing that even though the option says cie/it8 file, maybe only
> it8 files are well supported?  Or maybe the one that Argyll ships with
> is just malformed.  Does anyone have an idea where I might find a usable
> it8 file for the ColorChecker passport?  This seems like something that
> should be prominently published by the manufacturer, but the only place
> I was able to find cht and cie files at all was in the Argyll distribution

The file ColorCheckerPassport.cie as shipped by Argyll uses "SAMPLE_LOC" 
instead of "SAMPLE_ID" to refer to the colors. Just changing the line

SAMPLE_LOC XYZ_X XYZ_Y XYZ_Z LAB_L LAB_A LAB_B

to

SAMPLE_ID XYZ_X XYZ_Y XYZ_Z LAB_L LAB_A LAB_B

made it work for me. At least darktable-chart no longer complained. That being 
said, the Lab values dt-chart computes from the XYZ reference numbers look off 
to me. I'll have a look.

> Thanks,
> Robby

Tobias

signature.asc