Bug#574805: please try to reproduce with newest powertop version

2012-04-19 Thread Eshat Cakar
On Mon 21 March 2011 09:18:51 Frédéric Boiteux wrote:
 As Raúl said, I don't see any power measure in this new release of
 powertop (lot of added information, but need some info to understand
 how to use them). How / Where can you see the power consumption ?

This information is meant to be displayed at the top line of the Overview 
tab.
However, I had a closer look at the source and it seems, that this information 
might not be available on many (all?) systems, since powertop 1.97 only checks 
in the deprecated /proc/acpi/battery/ directory for consumtion information.

I managed to patch powertop to use /sys/class/power_supply/BAT0/, that should 
be available on systems with modern kernels, so that I got proper consumtion 
displayed on my thinkpad X201, but since that (dirty) patch might break 
functionality on other notebooks (especially since different units seem to be 
used across systems), it's not a global solution, hence not attaached :).

I propose to wait for upstream to fix this. In the meantime you can use 
acpitool -B to get detailed battery status information.

Best regards

-- 
eshat cakar
web: www.eshat.de   gpg-id: 799B 95D5




--
To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org
with a subject of unsubscribe. Trouble? Contact listmas...@lists.debian.org



Bug#574805: please try to reproduce with newest powertop version

2011-03-21 Thread Frédéric Boiteux
Le Sun, 20 Mar 2011 18:07:06 +0100,
Raúl Sánchez Siles rasas...@gmail.com a écrit :

   Hello:
 
 El Viernes, 18 de Marzo de 2011, Patrick Winnertz escribió:
  hey,
  
  can please someone else also try to reproduce with the newest
  powertop version (1.97-2) in unstable? On my laptop this works
  flawlessly, but I really want to have another test before i close
  this report.
 
   I'm not sure this is really fixed, since powertop 2 is not
 reporting instant power consumption, I guess I need to perform a
 callibration first.

  Hello,

As Raúl said, I don't see any power measure in this new release of
powertop (lot of added information, but need some info to understand
how to use them). How / Where can you see the power consumption ?

  By the way, I've found that the man page is missing.


 Fred.



--
To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org
with a subject of unsubscribe. Trouble? Contact listmas...@lists.debian.org



Bug#574805: please try to reproduce with newest powertop version

2011-03-20 Thread Raúl Sánchez Siles
  Hello:

El Viernes, 18 de Marzo de 2011, Patrick Winnertz escribió:
 hey,
 
 can please someone else also try to reproduce with the newest powertop
 version (1.97-2) in unstable? On my laptop this works flawlessly, but I
 really want to have another test before i close this report.

  I'm not sure this is really fixed, since powertop 2 is not reporting instant 
power consumption, I guess I need to perform a callibration first.

  So I'm sorry I'm unable to help (yet). I'll try with a callibration and I'll 
come back.

 
 Greetings
 Winnie
 
 ps: If there is no answer within 2 weeks, I'll close this bugreport as the
 issue seems to be finally fixed in 1.97...

  Thanks for your work on powertop 2.

  Regards,

-- 
 Raúl Sánchez Siles
-Proud Debian user-
Linux registered user #416098


signature.asc
Description: This is a digitally signed message part.


Bug#574805: please try to reproduce with newest powertop version

2011-03-18 Thread Patrick Winnertz
hey,

can please someone else also try to reproduce with the newest powertop 
version (1.97-2) in unstable? On my laptop this works flawlessly, but I 
really want to have another test before i close this report. 

Greetings
Winnie

ps: If there is no answer within 2 weeks, I'll close this bugreport as the 
issue seems to be finally fixed in 1.97...


signature.asc