Bug#983554: inkscape: Measurement path effect scale inaccurate after changing display units in document properties

2021-02-27 Thread Mattia Rizzolo
Control: forwarded -1 https://gitlab.com/inkscape/inkscape/-/issues/1746

On Fri, Feb 26, 2021 at 11:07:51AM -0800, Will C. wrote:
> The linked issue is similar. From what I found from my search, this
> issue is related to:
> https://gitlab.com/inkscape/inkscape/-/issues/1746

Thank you.  I've set this debian bug to track this one then.

> and the issue you linked above. Both of which can also be replicated
> with a new installation of inkscape from the debian repos.

Following both bug reports there seems to be several bugs concerning
this feature.  Hopefully they'll be fixed at some point.

-- 
regards,
Mattia Rizzolo

GPG Key: 66AE 2B4A FCCF 3F52 DA18  4D18 4B04 3FCD B944 4540  .''`.
More about me:  https://mapreri.org : :'  :
Launchpad user: https://launchpad.net/~mapreri  `. `'`
Debian QA page: https://qa.debian.org/developer.php?login=mattia  `-


signature.asc
Description: PGP signature


Bug#983554: inkscape: Measurement path effect scale inaccurate after changing display units in document properties

2021-02-26 Thread Will C.
The linked issue is similar. From what I found from my search, this
issue is related to:
https://gitlab.com/inkscape/inkscape/-/issues/1746

and the issue you linked above. Both of which can also be replicated
with a new installation of inkscape from the debian repos.

On Fri, Feb 26, 2021 at 8:12 AM Mattia Rizzolo  wrote:
>
> Control: tag -1 upstream
>
> Hi Will,
>
> On Thu, Feb 25, 2021 at 10:54:34PM -0800, will wrote:
> > Changing the Display Units to anything other than the default mm throws off 
> > the
> > measurement path effect.
> >
> > With the default display unit (mm), the measurements are displayed 
> > correctly.
> > The file with display unit changed to inches shows an incorrect measurement.
> > Other units are also affected, for example: cm is off by a factor of x10.
>
> Could I ask you to please read this other bugs report and check whether
> that matches what you are reporting?
> https://gitlab.com/inkscape/inkscape/-/issues/1675
>
> Thank you in advance!
>
> --
> regards,
> Mattia Rizzolo
>
> GPG Key: 66AE 2B4A FCCF 3F52 DA18  4D18 4B04 3FCD B944 4540  .''`.
> More about me:  https://mapreri.org : :'  :
> Launchpad user: https://launchpad.net/~mapreri  `. `'`
> Debian QA page: https://qa.debian.org/developer.php?login=mattia  `-



Bug#983554: inkscape: Measurement path effect scale inaccurate after changing display units in document properties

2021-02-26 Thread Mattia Rizzolo
Control: tag -1 upstream

Hi Will,

On Thu, Feb 25, 2021 at 10:54:34PM -0800, will wrote:
> Changing the Display Units to anything other than the default mm throws off 
> the
> measurement path effect.
> 
> With the default display unit (mm), the measurements are displayed correctly.
> The file with display unit changed to inches shows an incorrect measurement.
> Other units are also affected, for example: cm is off by a factor of x10.

Could I ask you to please read this other bugs report and check whether
that matches what you are reporting?
https://gitlab.com/inkscape/inkscape/-/issues/1675

Thank you in advance!

-- 
regards,
Mattia Rizzolo

GPG Key: 66AE 2B4A FCCF 3F52 DA18  4D18 4B04 3FCD B944 4540  .''`.
More about me:  https://mapreri.org : :'  :
Launchpad user: https://launchpad.net/~mapreri  `. `'`
Debian QA page: https://qa.debian.org/developer.php?login=mattia  `-


signature.asc
Description: PGP signature


Bug#983554: inkscape: Measurement path effect scale inaccurate after changing display units in document properties

2021-02-25 Thread will
Package: inkscape
Version: 1.0.2-3
Severity: normal
X-Debbugs-Cc: wiiliamchung...@gmail.com

Dear Maintainer,

Changing the Display Units to anything other than the default mm throws off the
measurement path effect.

Attached documents includes a box scaled to 5 x 10 inch with measurement path
applied.

With the default display unit (mm), the measurements are displayed correctly.
The file with display unit changed to inches shows an incorrect measurement.
Other units are also affected, for example: cm is off by a factor of x10.

-- System Information:
Debian Release: bullseye/sid
  APT prefers testing
  APT policy: (500, 'testing'), (100, 'experimental'), (100, 'unstable')
Architecture: amd64 (x86_64)
Foreign Architectures: i386

Kernel: Linux 5.10.0-3-amd64 (SMP w/24 CPU threads)
Kernel taint flags: TAINT_OOT_MODULE, TAINT_UNSIGNED_MODULE
Locale: LANG=en_US.UTF-8, LC_CTYPE=en_US.UTF-8 (charmap=UTF-8), LANGUAGE not
set
Shell: /bin/sh linked to /usr/bin/dash
Init: systemd (via /run/systemd/system)
LSM: AppArmor: enabled

Versions of packages inkscape depends on:
ii  libatkmm-1.6-1v5   2.28.0-3
ii  libc6  2.31-9
ii  libcairo2  1.16.0-5
ii  libcairomm-1.0-1v5 1.12.2-4
ii  libcdr-0.1-1   0.1.6-2
ii  libdbus-glib-1-2   0.110-6
ii  libdouble-conversion3  3.1.5-6.1
ii  libfontconfig1 2.13.1-4.2
ii  libfreetype6   2.10.4+dfsg-1
ii  libgc1 1:8.0.4-3
ii  libgcc-s1  10.2.1-6
ii  libgdk-pixbuf-2.0-02.42.2+dfsg-1
ii  libgdl-3-5 3.34.0-1
ii  libglib2.0-0   2.66.7-1
ii  libglibmm-2.4-1v5  2.64.2-2
ii  libgomp1   10.2.1-6
ii  libgsl25   2.6+dfsg-2
ii  libgtk-3-0 3.24.24-1
ii  libgtkmm-3.0-1v5   3.24.2-2
ii  libgtkspell3-3-0   3.0.10-1
ii  libharfbuzz0b  2.7.4-1
ii  libjpeg62-turbo1:2.0.5-2
ii  liblcms2-2 2.12~rc1-2
ii  libmagick++-6.q16-88:6.9.11.60+dfsg-1
ii  libpango-1.0-0 1.46.2-3
ii  libpangocairo-1.0-01.46.2-3
ii  libpangoft2-1.0-0  1.46.2-3
ii  libpangomm-1.4-1v5 2.42.1-1
ii  libpng16-161.6.37-3
ii  libpoppler-glib8   20.09.0-3.1
ii  libpoppler102  20.09.0-3.1
ii  libpotrace01.16-2
ii  librevenge-0.0-0   0.0.4-6+b1
ii  librsvg2-common2.50.3+dfsg-1
ii  libsigc++-2.0-0v5  2.10.4-2
ii  libsoup2.4-1   2.72.0-2
ii  libstdc++6 10.2.1-6
ii  libvisio-0.1-1 0.1.7-1+b1
ii  libwpg-0.3-3   0.3.3-1
ii  libx11-6   2:1.7.0-2
ii  libxml22.9.10+dfsg-6.3+b1
ii  libxslt1.1 1.1.34-4
ii  python33.9.1-1
ii  zlib1g 1:1.2.11.dfsg-2

Versions of packages inkscape recommends:
ii  aspell   0.60.8-2
ii  fig2dev  1:3.2.8-2
ii  imagemagick  8:6.9.11.60+dfsg-1
ii  imagemagick-6.q16 [imagemagick]  8:6.9.11.60+dfsg-1
ii  libimage-magick-perl 8:6.9.11.60+dfsg-1
ii  libwmf-bin   0.2.8.4-17
ii  python3-lxml 4.6.2-1
ii  python3-numpy1:1.19.5-1
ii  python3-scour0.38.2-1

Versions of packages inkscape suggests:
pn  dia   
pn  inkscape-tutorials
pn  libsvg-perl   
pn  libxml-xql-perl   
pn  pstoedit  
pn  python3-uniconvertor  
ii  ruby  1:2.7+2