[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2019-02-03 Thread Richard Eames
After going on the #radeon channel on Freenode, we narrowed the problem
down to the switcheroo-control package. We started by hand making an
xorg.conf file and disabling gpu-manager, but still had issues. Looking
at the dmesg log, we saw that the discrete gpu is enabled at first, then
disabled sometime in the systemd start up. After trying to disable
various things, including switcheroo, from the kernel parameters and
having the problem still occur, we narrowed it down to being a service
that was writing to `/sys/kernel/debug/vgaswitcheroo/switch`. I looked
at my enabled services, and saw `switcheroo-control`, after disabling,
everything started working again.

Given that the package was integrated into gnome in late 2016 [0][1], it
lines up timewise with when I started having problems.

[0] 
https://askubuntu.com/questions/1034882/gnome-does-not-show-the-option-to-use-dedicated-graphics-card-on-right-click
[1] http://www.hadess.net/2016/10/dual-gpu-integration-in-gnome.html

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  Invalid
Status in xserver-xorg-driver-radeonhd:
  Invalid
Status in lightdm package in Ubuntu:
  Invalid
Status in switcheroo-control package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2019-02-03 Thread Richard Eames
** Also affects: switcheroo-control (Ubuntu)
   Importance: Undecided
   Status: New

** Changed in: lightdm (Ubuntu)
   Status: New => Invalid

** Changed in: lightdm
   Status: New => Invalid

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  Invalid
Status in xserver-xorg-driver-radeonhd:
  Invalid
Status in lightdm package in Ubuntu:
  Invalid
Status in switcheroo-control package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2019-02-03 Thread Richard Eames
** Attachment added: "xorg log"
   
https://bugs.launchpad.net/ubuntu/+source/lightdm/+bug/1692437/+attachment/5235697/+files/Xorg.0.log

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  New
Status in xserver-xorg-driver-radeonhd:
  Invalid
Status in lightdm package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2019-02-03 Thread Richard Eames
Added gpu-manager log

It says "Unsupported discrete card vendor: 1002",
Does this mean my discrete card is no longer supported?

** Attachment added: "gpu-manager.log"
   
https://bugs.launchpad.net/ubuntu/+source/lightdm/+bug/1692437/+attachment/5235683/+files/gpu-manager.log

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  New
Status in xserver-xorg-driver-radeonhd:
  Invalid
Status in lightdm package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2019-02-01 Thread Richard Eames
I filmed my computer boot up to better show what happens. The right
monitor is on the integrated video card (the R7), and doesn't show
anything initially. The center and left monitor turn on and mirror each
other during boot, and show grub and most of the kernel and systemd
messages, then at some point all output is sent to the right monitor. I
believe the systemd log says something along the lines of "detecting all
video cards" at that point.

** Attachment added: "Computerbootup.webm"
   
https://bugs.launchpad.net/ubuntu/+source/lightdm/+bug/1692437/+attachment/5235238/+files/Computerbootup.webm

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  New
Status in xserver-xorg-driver-radeonhd:
  Invalid
Status in lightdm package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2019-02-01 Thread Richard Eames
** Attachment added: "dmesg log"
   
https://bugs.launchpad.net/ubuntu/+source/lightdm/+bug/1692437/+attachment/5235234/+files/dmesg.log

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  New
Status in xserver-xorg-driver-radeonhd:
  Invalid
Status in lightdm package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2019-02-01 Thread Richard Eames
I've come across this again after upgrading to 18.10

$ xrandr --listproviders  
Providers: number : 1
Provider 0: id: 0x56 cap: 0x9, Source Output, Sink Offload crtcs: 4 outputs: 3 
associated providers: 0 name:KAVERI @ pci::00:01.0

$ sudo lspci -nn | grep -E 'VGA|Display'
[sudo] password for richard: 
00:01.0 VGA compatible controller [0300]: Advanced Micro Devices, Inc. 
[AMD/ATI] Kaveri [Radeon R7 Graphics] [1002:1313]
01:00.0 VGA compatible controller [0300]: Advanced Micro Devices, Inc. 
[AMD/ATI] RV770 [Radeon HD 4850] [1002:9442]

Only the built-in Radeon R7 is being used

** Changed in: lightdm
   Status: Invalid => New

** Changed in: lightdm (Ubuntu)
   Status: Invalid => New

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  New
Status in xserver-xorg-driver-radeonhd:
  Invalid
Status in lightdm package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2018-01-30 Thread dino99
That version is now dead
http://news.softpedia.com/news/ubuntu-17-04-zesty-zapus-has-reached-end-of-life-upgrade-to-ubuntu-17-10-now-519360.shtml

** Changed in: lightdm (Ubuntu)
   Status: New => Invalid

** Changed in: lightdm
   Status: New => Invalid

** Changed in: xserver-xorg-driver-radeonhd
   Status: New => Invalid

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  Invalid
Status in xserver-xorg-driver-radeonhd:
  Invalid
Status in lightdm package in Ubuntu:
  Invalid

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2017-07-28 Thread Richard Eames
Is there anything I can do to move this along?

I'm fairly certain it's a kernel or driver issue since zesty since I'm
currently running 16.04 on live USB and all three monitors work just
fine. I've tried using the 4.8 kernel from yakkety, but I couldn't get
it to boot, I'm assuming it was compiled specifically for yakkety.

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  New
Status in xserver-xorg-driver-radeonhd:
  New
Status in lightdm package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2017-06-03 Thread Richard Eames
Some more information:

- If I switch my primary display adapter in BIOS to the onboard GPU, I can get 
all three monitors and two cards working, but the framerate on the monitors 
attached to the PEG GPU is so low that it's almost unusable.
- If I set the PEG GPU as primary display adapter, all three monitors work 
until it gets to the lightdm greeter where only the monitor attached to the 
integrated gpu works.

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  New
Status in xserver-xorg-driver-radeonhd:
  New
Status in lightdm package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2017-06-01 Thread Richard Eames
I'm beginning to think this is a driver issue. I have a builtin "Kaveri"
amd gpu, and pci Radeon HD 4850. I usually have the 4850 as my primary
card/monitor setup. However, since upgrading to Ubuntu 17.04, once
lightdm is started, only the monitor on the Kaveri works.

I dropped to VT1, and ran `X -configure` after shutting lightdm down,
and received an error:

amdgpu_device_initialize: DRM version is 2.49.0 but this driver is only
compatible with 3.x.x

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  New
Status in xserver-xorg-driver-radeonhd:
  New
Status in lightdm package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2017-05-22 Thread Richard Eames
lspci and lshw show 2 GPUs. The builtin one, and the actual card, but
xrandr only lists one provider.

$ xrandr --listproviders 
Providers: number : 1
Provider 0: id: 0x56 cap: 0x9, Source Output, Sink Offload crtcs: 4 outputs: 3 
associated providers: 0 name:KAVERI @ pci::00:01.0


Might be a bug in the radeon driver?

** Also affects: lightdm
   Importance: Undecided
   Status: New

** Also affects: xserver-xorg-driver-radeonhd
   Importance: Undecided
   Status: New

** Attachment added: "lspci -vvv"
   
https://bugs.launchpad.net/xserver-xorg-driver-radeonhd/+bug/1692437/+attachment/4881502/+files/lspci.txt

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in Light Display Manager:
  New
Status in xserver-xorg-driver-radeonhd:
  New
Status in lightdm package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp


[Desktop-packages] [Bug 1692437] Re: Monitors on second GPU not working after upgrade to zesty

2017-05-22 Thread Richard Eames
** Attachment added: "lshw output"
   
https://bugs.launchpad.net/ubuntu/+source/lightdm/+bug/1692437/+attachment/4881175/+files/lshw.txt

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to lightdm in Ubuntu.
https://bugs.launchpad.net/bugs/1692437

Title:
  Monitors on second GPU not working after upgrade to zesty

Status in lightdm package in Ubuntu:
  New

Bug description:
  I'm not 100% sure this is the right package to file the bug against,
  but since upgrading to zesty the two monitors on my second GPU are no
  longer detected once I reach the greeter screen at login time.
  However, both of them display information during boot.

  Let me know how I can narrow down the bug report.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.04
  Package: lightdm 1.22.0-0ubuntu2.1
  ProcVersionSignature: Ubuntu 4.8.0-52.55-generic 4.8.17
  Uname: Linux 4.8.0-52-generic x86_64
  ApportVersion: 2.20.4-0ubuntu4
  Architecture: amd64
  CurrentDesktop: GNOME
  Date: Mon May 22 01:42:58 2017
  EcryptfsInUse: Yes
  InstallationDate: Installed on 2016-04-29 (388 days ago)
  InstallationMedia: Ubuntu 16.04 LTS "Xenial Xerus" - Release amd64 
(20160420.1)
  SourcePackage: lightdm
  UpgradeStatus: Upgraded to zesty on 2017-05-22 (0 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/lightdm/+bug/1692437/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp