Re: [Elecraft] [K2] 2nd Xtal Filter and Product Detector Output problems

2009-05-08 Thread Don Wilhelm
Jim,

If you had the expected output at U12 pin 8, but less than expected at 
U11 pin 1, then there is a problem between those two points.  Look at 
the schematic in conjunction with these troubleshooting steps to find 
what lies between the two points - in this case, look in the lower right 
quadrant of RF Board schematic sheet 2.

Since the signal is going through a crystal filter, move the frequency a 
little bit to see if the level increases. 

Concentrate on the 2nd IF filter before proceeding to the Product Detector.

73,
Don W3FPR

Jim Brown wrote:
 I am using the procedures in a Rev C manual, Appendix E, Page 10-11 to
 troubleshoot a dead receiver problem. All Rework Eliminators are
 installed. Signal tracing through the PLL/VCO and Low-Pass Filter,
 Bandpass Filter, and T-R Switch produced expected measurements. In the
 Mixer, I.F. Amp, and Xtal Filter section, some anomalies were found.
 Specifically, the 2nd Crystal Filter Output measured at U11 pin 1
 expects 0.27Vrms but measures only 0.17Vrms (paragraph 9). The Product
 Detector Saturated Output measurement expects 0.58Vrms but measures
 only 0.08Vrms (paragraph 10). These measurements produced with input
 of 0.15Vrms as measured at U12, pin 8 per instructions in paragraph 8.

 I reheated solder joints on all components around these sections with
 no change of measurements. Any help appreciated.


 Regards,
 Jim Brown, K5JAZ
 __
 Elecraft mailing list
 Home: http://mailman.qth.net/mailman/listinfo/elecraft
 Help: http://mailman.qth.net/mmfaq.htm
 Post: mailto:Elecraft@mailman.qth.net

 This list hosted by: http://www.qsl.net
 Please help support this email list: http://www.qsl.net/donate.html
 


 No virus found in this incoming message.
 Checked by AVG - www.avg.com 
 Version: 8.5.325 / Virus Database: 270.12.21/2102 - Release Date: 05/07/09 
 05:57:00

   
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html


[Elecraft] [K2] 2nd Xtal Filter and Product Detector Output problems

2009-05-07 Thread Jim Brown
I am using the procedures in a Rev C manual, Appendix E, Page 10-11 to
troubleshoot a dead receiver problem. All Rework Eliminators are
installed. Signal tracing through the PLL/VCO and Low-Pass Filter,
Bandpass Filter, and T-R Switch produced expected measurements. In the
Mixer, I.F. Amp, and Xtal Filter section, some anomalies were found.
Specifically, the 2nd Crystal Filter Output measured at U11 pin 1
expects 0.27Vrms but measures only 0.17Vrms (paragraph 9). The Product
Detector Saturated Output measurement expects 0.58Vrms but measures
only 0.08Vrms (paragraph 10). These measurements produced with input
of 0.15Vrms as measured at U12, pin 8 per instructions in paragraph 8.

I reheated solder joints on all components around these sections with
no change of measurements. Any help appreciated.


Regards,
Jim Brown, K5JAZ
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html