Re: [Elecraft] Elecraft K2 7855, alignment and test part II, bad PLL frequency.

2020-05-07 Thread Don Wilhelm

Chris,

Congratulations.  Leave the capacitor in and go on.  On other words, 
treat it as a permanent fix - you might also want to add it to your 
schematic.

No need to change Q19.

73,
Don W3FPR

On 5/7/2020 12:25 PM, Christophe GIBERT wrote:

Hey ! I’ve soldered a 20pF capacitor that i’d from personal stock between U4 
pin 1 and U4 pin 12 (ground), and all is good !

I can go to BFO Test without  any problem !

Does this mod could be considered as definitive or should I change Q19 with 
another J310 ?

Thanks a lot for the super hyper quick help! :-)

Best regards.

—
Chris


Le 6 mai 2020 à 23:37, Don Wilhelm  a écrit :

Chris,

Your English is much better than my French!  I hope you can understand the 
following:

You have a Q19 that is not willing to work at the high frequency end of the PLL 
range.

The proper thing to do is replace Q19 with a J310 FET that is better. Order one 
from Elecraft (email to supp...@elecraft.com) with the part number.

What you can try is to add a small value capacitor (12 or 15pF) from U4 pin 1 
to U4 pin 12 (ground) to see if that restores proper function.  If you do not 
have a stock of small capacitors, use the 12pF in the K2 kit which you have not 
yet installed and order a replacement from Elecraft.

Proper functioning thru-hole J310s have been a problem since Elecraft ran out 
of the old ones and found that they had been discontinued by the manufacturer.

I know of one ham in Europe who used an SMD J310 as a replacement - but if you 
consider that, know that the basing is not the same and you would have to go 
from the data sheet to know which pin to connect to the holes.  He mounted it 
on the bottom of the board.

73,
Don W3FPR


On 5/6/2020 4:44 PM, Christophe GIBERT wrote:
Hi! First of all, sorry for my poor english, i’m french ;-)
I’m building my k2 number 7855.
In the first step of the 4mhz oscillator calibration, i get a frequency of 
00500.00 instead of 12090.00
When i press BAND + : 00475.00 and BAND - : 12085.43 (stable).
I’ve tested probe on TP2, I’d 4913.52
I reviewed all components in the pll schematics and nothing seems wrong.
Please help me, i don’t know what to look for now.
Thanks a lot.
—
Chris
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to donw...@embarqmail.com


__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

Re: [Elecraft] Elecraft K2 7855, alignment and test part II, bad PLL frequency.

2020-05-07 Thread Christophe GIBERT

Hey ! I’ve soldered a 20pF capacitor that i’d from personal stock between U4 
pin 1 and U4 pin 12 (ground), and all is good ! 

I can go to BFO Test without  any problem !

Does this mod could be considered as definitive or should I change Q19 with 
another J310 ?

Thanks a lot for the super hyper quick help! :-)

Best regards.

— 
Chris

> Le 6 mai 2020 à 23:37, Don Wilhelm  a écrit :
> 
> Chris,
> 
> Your English is much better than my French!  I hope you can understand the 
> following:
> 
> You have a Q19 that is not willing to work at the high frequency end of the 
> PLL range.
> 
> The proper thing to do is replace Q19 with a J310 FET that is better. Order 
> one from Elecraft (email to supp...@elecraft.com) with the part number.
> 
> What you can try is to add a small value capacitor (12 or 15pF) from U4 pin 1 
> to U4 pin 12 (ground) to see if that restores proper function.  If you do not 
> have a stock of small capacitors, use the 12pF in the K2 kit which you have 
> not yet installed and order a replacement from Elecraft.
> 
> Proper functioning thru-hole J310s have been a problem since Elecraft ran out 
> of the old ones and found that they had been discontinued by the manufacturer.
> 
> I know of one ham in Europe who used an SMD J310 as a replacement - but if 
> you consider that, know that the basing is not the same and you would have to 
> go from the data sheet to know which pin to connect to the holes.  He mounted 
> it on the bottom of the board.
> 
> 73,
> Don W3FPR
> 
>> On 5/6/2020 4:44 PM, Christophe GIBERT wrote:
>> Hi! First of all, sorry for my poor english, i’m french ;-)
>> I’m building my k2 number 7855.
>> In the first step of the 4mhz oscillator calibration, i get a frequency of 
>> 00500.00 instead of 12090.00
>> When i press BAND + : 00475.00 and BAND - : 12085.43 (stable).
>> I’ve tested probe on TP2, I’d 4913.52
>> I reviewed all components in the pll schematics and nothing seems wrong.
>> Please help me, i don’t know what to look for now.
>> Thanks a lot.
>> —
>> Chris
>> __
>> Elecraft mailing list
>> Home: http://mailman.qth.net/mailman/listinfo/elecraft
>> Help: http://mailman.qth.net/mmfaq.htm
>> Post: mailto:Elecraft@mailman.qth.net
>> This list hosted by: http://www.qsl.net
>> Please help support this email list: http://www.qsl.net/donate.html
>> Message delivered to donw...@embarqmail.com
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

Re: [Elecraft] Elecraft K2 7855, alignment and test part II, bad PLL frequency.

2020-05-06 Thread Don Wilhelm

Chris,

Your English is much better than my French!  I hope you can understand 
the following:


You have a Q19 that is not willing to work at the high frequency end of 
the PLL range.


The proper thing to do is replace Q19 with a J310 FET that is better. 
Order one from Elecraft (email to supp...@elecraft.com) with the part 
number.


What you can try is to add a small value capacitor (12 or 15pF) from U4 
pin 1 to U4 pin 12 (ground) to see if that restores proper function.  If 
you do not have a stock of small capacitors, use the 12pF in the K2 kit 
which you have not yet installed and order a replacement from Elecraft.


Proper functioning thru-hole J310s have been a problem since Elecraft 
ran out of the old ones and found that they had been discontinued by the 
manufacturer.


I know of one ham in Europe who used an SMD J310 as a replacement - but 
if you consider that, know that the basing is not the same and you would 
have to go from the data sheet to know which pin to connect to the 
holes.  He mounted it on the bottom of the board.


73,
Don W3FPR

On 5/6/2020 4:44 PM, Christophe GIBERT wrote:

Hi! First of all, sorry for my poor english, i’m french ;-)

I’m building my k2 number 7855.

In the first step of the 4mhz oscillator calibration, i get a frequency of 
00500.00 instead of 12090.00

When i press BAND + : 00475.00 and BAND - : 12085.43 (stable).

I’ve tested probe on TP2, I’d 4913.52

I reviewed all components in the pll schematics and nothing seems wrong.

Please help me, i don’t know what to look for now.

Thanks a lot.

—
Chris
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to donw...@embarqmail.com


__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

[Elecraft] Elecraft K2 7855, alignment and test part II, bad PLL frequency.

2020-05-06 Thread Christophe GIBERT
Hi! First of all, sorry for my poor english, i’m french ;-)

I’m building my k2 number 7855. 

In the first step of the 4mhz oscillator calibration, i get a frequency of 
00500.00 instead of 12090.00 

When i press BAND + : 00475.00 and BAND - : 12085.43 (stable).

I’ve tested probe on TP2, I’d 4913.52

I reviewed all components in the pll schematics and nothing seems wrong. 

Please help me, i don’t know what to look for now.

Thanks a lot.

— 
Chris
__
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html