RE: NEBS secondary protectors

2001-05-03 Thread dfrazee


Dwight,

Read up in GR-1089, Section 4.  You must declare these interfaces not to be
outside plant and to specify appropriate protective devices to be used.
Propose to your NRTL skipping the 1089, sec. 4 tests and including the
following statement in your user documentation, Before leaving the
building premesis, interface lines connected to the xx must be
connected to a NRTL Listed device providing primary and secondary
protection.

Doug Frazee
Regulatory Compliance Manager
Lucent Technologies, Broadband Carrier Networks
Access Technology Division
InterNetworking Systems
(301) 809-4415
(301) 352-4730 FAX
dfra...@lucent.com



   
JIM WIESE   
   
jim.wiese@adTo: emc-pstc emc-p...@ieee.org, 
n...@world.std.com  
tran.comcc:
   
Sent by: Subject: RE: NEBS secondary 
protectors
owner-emc-pst   
   
c...@ieee.org   
  

   

   
05/02/01
   
04:12 PM
   
Please  
   
respond to  
   
JIM WIESE   
   

   

   





Dwight,

I would love to help, but I do not have any wisdom in this area.  All of
ADTRAN's Carrier class equipment has this automatically built in.


Sorry,
Jim

Jim Wiese
NEBS Project Manager/Compliance Engineer
ADTRAN, INC.
901 Explorer Blvd.
P.O. Box 14
Huntsville, AL 35814-4000
256-963-8431
256-963-8250 fax
jim.wi...@adtran.com

A successful man is one who can lay a strong foundation with the bricks
thrown at him by others. - David Brinkley-


 --
 From: Dwight Hunnicutt[SMTP:dwight.hunnic...@vina-tech.com]
 Reply To:  n...@world.std.com
 Sent: Wednesday, May 02, 2001 2:02 PM
 To:   Emc-Pstc@Ieee. Org (E-mail)
 Cc:   Nebs@World. Std. Com (E-mail)
 Subject:   RE: NEBS secondary protectors

 Jim! are you out there??  Grace us with your wisdom...

 -Original Message-
 From: Don House [mailto:dho...@excelsus-tech.com]
 Sent: Wednesday, May 02, 2001 10:47 AM
 To: dwight.hunnic...@vina-tech.com
 Subject: RE: NEBS secondary protectors


 Check with Jim Wiese at ADTRAN.  He knows ALOT about this subject.

 Don

 Don Robert House
 Sr. Member Technical Staff
 Excelsus Technologies, Inc.
 2875 Loker Avenue East
 Carlsbad, CA 92008-6626
 (760)918-2552 Office
 (760)476-1519 FAX -Original Message-
 From: Dwight Hunnicutt [mailto:dwight.hunnic...@vina-tech.com]
 Sent: Wednesday, May 02, 2001 9:58 AM
 To: Emc-Pstc@Ieee. Org (E-mail)
 Cc: Nebs@World. Std. Com (E-mail)
 Subject: NEBS secondary protectors


 NEBS folks-

 Anyone know of external secondary protectors that can be installed
outside
 of one's product to pass GR-1089 lightning and power cross testing?  That
 is, if we don't have room on our boards for the fuse/sidactor circuitry,
I
 understand a company can specify a certain protector be installed with
the
 product to meet the requirement.  Any experience doing this?  thanks

 Dwight


---
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
 majord...@ieee.org
with the single line:
 unsubscribe emc-pstc

For help, send mail to the list administrators:
 Michael Garretson:pstc_ad...@garretson.org
 Dave Healddavehe...@mediaone.net

For policy questions, send mail to:
 Richard Nute:   ri...@ieee.org
 Jim Bacher:   

EMC Engineer-Lucent

2000-07-18 Thread dfrazee

EMC Compliance Engineer
Job description:
As a key member of a small team of regulatory compliance professionals, you
will:
 Research, administer and implement international EMC compliance
 requirements for Lucent's ATM access equipment.

 Perform pre-compliance evaluations, simulations and analysis to ensure
 success during 3rd-party testing.

 Support and manage 3rd-party testing facilities, including occasional
 travel.

 Provide consultation to engineering and manufacturing teams in aspects
 of product design and manufacturing relating to EMC compliance.

 Support marketing and sales teams with respect to regulatory issues.
Qualifications:
 BSEE with 2+ years industry related compliance experience, including
 hands-on compliance test experience.

 Extensive knowledge of domestic, European and international EMC
 standards including GR-1089-CORE, FCC Part 15, CISPR 22, EN 300 386.

 High-speed digital EMC design experience and ability to provide
 consultation to the design team a plus.

 Excellent organizational, communication and research skills.

Lucent offers a dynamic, flexible working environment, competitive salaries
with excellent benefits, 401k and stock-options.

Contact:
Doug Frazee
Lucent Technologies
Access Technology Division
8301 Professional Place
Landover, MD  20785-2229
dfra...@lucent.com
(301) 809-4450 FAX



---
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

To cancel your subscription, send mail to:
 majord...@ieee.org
with the single line:
 unsubscribe emc-pstc

For help, send mail to the list administrators:
 Jim Bacher:  jim_bac...@mail.monarch.com
 Michael Garretson:pstc_ad...@garretson.org

For policy questions, send mail to:
 Richard Nute:   ri...@ieee.org



Re: Telecom Regulatory Generator

2000-03-30 Thread dfrazee

Several organizations publish telcom approval guidebooks.  I use the BHS
International guidebooks.  There are 6 guidebooks, based on global regions.
An update service is also available.  www.bhsintl.com

Doug Frazee
Regulatory Compliance Manager
Lucent Technologies, Broadband Carrier Networks
Access Technology Division
InterNetworking Systems
(301) 809-4415
(301) 809-4450 FAX
dfra...@lucent.com




Art Michael amich...@connix.com on 03/30/2000 09:06:05 AM

Please respond to Art Michael amich...@connix.com

To:   Peter Merguerian pmerguer...@itl.co.il
cc:   emc-p...@majordomo.ieee.org (bcc: Doug Frazee/HQ/Yurie)
Subject:  Re: Telecom Regulatory Generator





Hello Peter,

Try the following sources:

InterConnect Communications (UK)  www.icc-uk.com

and

   Horrockwww.horrocks.co.uk



Regards, Art Michael

Int'l Product Safety News
A.E. Michael, Publisher/Editor
166 Congdon St. East
P.O. Box 1561
Middletown CT 06457 U.S.A.

Phone  :  (860) 344-1651
Fax:  (860) 346-9066
Email  :  i...@connix.com
Website:  http://www.safetylink.com
ISSN   :  1040-7529
---
--
On Thu, 30 Mar 2000, Peter Merguerian wrote:


 Dear All,

 Anyone knows of a telecom regulatory generator where one can easily
find
 the regulatory requirements in a particular country, including but not
 limited to: regulating authorities and contacts; test labs and contacts;
 applicable safety/emc/telecom standards and mutual recognitions
(acceptance
 of international test reports).

 Thanks
 Peter Merguerian
 Managing Director
 Product Testing Division
 I.T.L. (Product Testing) Ltd.
 Hacharoshet 26, POB 211
 Or Yehuda 60251, Israel

 Tel: 972-3-5339022 Fax: 972-3-5339019
 e-mail: pmerguer...@itl.co.il
 website: http://www.itl.co.il






 ---
 This message is from the IEEE EMC Society Product Safety
 Technical Committee emc-pstc discussion list.

 To cancel your subscription, send mail to:
  majord...@ieee.org
 with the single line:
  unsubscribe emc-pstc

 For help, send mail to the list administrators:
  Jim Bacher:  jim_bac...@mail.monarch.com
  Michael Garretson:pstc_ad...@garretson.org

 For policy questions, send mail to:
  Richard Nute:   ri...@ieee.org





---
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

To cancel your subscription, send mail to:
 majord...@ieee.org
with the single line:
 unsubscribe emc-pstc

For help, send mail to the list administrators:
 Jim Bacher:  jim_bac...@mail.monarch.com
 Michael Garretson:pstc_ad...@garretson.org

For policy questions, send mail to:
 Richard Nute:   ri...@ieee.org









---
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

To cancel your subscription, send mail to:
 majord...@ieee.org
with the single line:
 unsubscribe emc-pstc

For help, send mail to the list administrators:
 Jim Bacher:  jim_bac...@mail.monarch.com
 Michael Garretson:pstc_ad...@garretson.org

For policy questions, send mail to:
 Richard Nute:   ri...@ieee.org