Re: [gmx-users] Erro in SMD simulation..

2014-04-19 Thread Kalyanashis
Thank you Justin so much... In case of this system rectangular (10x10x25)
is working.. SMD is over with out any error.. Thank you..


On Wed, Apr 2, 2014 at 12:03 AM, Justin Lemkul [via GROMACS] 
ml-node+s5086n5015557...@n6.nabble.com wrote:



 On 4/1/14, 2:18 PM, Kalyanashis wrote:
  Thank you so much Justin. Now I am trying with a rectangular box. I don
 not
  whether it will work or not.
 

 There shouldn't be any guesswork involved.  You know what the initial COM
 separation is (or you can easily calculate it or wait for grompp to print
 it
 out), and you know from pull_rate1 and the number of steps what the
 maximum
 displacement should be, so you can plan accordingly.

 -Justin

 --
 ==

 Justin A. Lemkul, Ph.D.
 Ruth L. Kirschstein NRSA Postdoctoral Fellow

 Department of Pharmaceutical Sciences
 School of Pharmacy
 Health Sciences Facility II, Room 601
 University of Maryland, Baltimore
 20 Penn St.
 Baltimore, MD 21201

 [hidden email] http://user/SendEmail.jtp?type=nodenode=5015557i=0 |
 (410) 706-7441
 http://mackerell.umaryland.edu/~jalemkul

 ==
 --
 Gromacs Users mailing list

 * Please search the archive at
 http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before
 posting!

 * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

 * For (un)subscribe requests visit
 https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or
 send a mail to [hidden 
 email]http://user/SendEmail.jtp?type=nodenode=5015557i=1.



 --
  If you reply to this email, your message will be added to the discussion
 below:

 http://gromacs.5086.x6.nabble.com/Erro-in-SMD-simulation-tp5015535p5015557.html
  To start a new topic under GROMACS Users Forum, email
 ml-node+s5086n4370410...@n6.nabble.com
 To unsubscribe from Erro in SMD simulation.., click 
 herehttp://gromacs.5086.x6.nabble.com/template/NamlServlet.jtp?macro=unsubscribe_by_codenode=5015535code=a2FseWFuLmNoZW0uaW5AZ21haWwuY29tfDUwMTU1MzV8NTkxMDYyNTYz
 .
 NAMLhttp://gromacs.5086.x6.nabble.com/template/NamlServlet.jtp?macro=macro_viewerid=instant_html%21nabble%3Aemail.namlbase=nabble.naml.namespaces.BasicNamespace-nabble.view.web.template.NabbleNamespace-nabble.view.web.template.NodeNamespacebreadcrumbs=notify_subscribers%21nabble%3Aemail.naml-instant_emails%21nabble%3Aemail.naml-send_instant_email%21nabble%3Aemail.naml




-- 
Kalyanashis Jana
email: kalyan.chem...@gmail.com


--
View this message in context: 
http://gromacs.5086.x6.nabble.com/Erro-in-SMD-simulation-tp5015535p5015936.html
Sent from the GROMACS Users Forum mailing list archive at Nabble.com.
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.


Re: [gmx-users] Reproducibility in free energy calculations.

2014-04-19 Thread Justin Lemkul



On 4/19/14, 1:16 AM, sujithkakkat . wrote:

Hello Justin,

I tried the free energy calculations in your tutorial at different sets
of conditions. Also I repeated a simulation at the same conditions with
same parameters, thrice on the same computer on same number of processors.
The results in the three cases where different (4.16 +/- 0.19 , 4.36
+/-0.14 , 4.54 +/-0.15 kJ/mol ) . I am not surprised, since I thought that
this might happen to a small system (241 water + 1 methane). However, I
want to be sure that this is OK. I guess in cases like this I should go for
an average value of many runs.



Offhand, I would have expected slightly better agreement between the runs, but 
there are tons of factors at play, so the outcome seems very plausible and 
reasonably consistent.


-Justin

--
==

Justin A. Lemkul, Ph.D.
Ruth L. Kirschstein NRSA Postdoctoral Fellow

Department of Pharmaceutical Sciences
School of Pharmacy
Health Sciences Facility II, Room 601
University of Maryland, Baltimore
20 Penn St.
Baltimore, MD 21201

jalem...@outerbanks.umaryland.edu | (410) 706-7441
http://mackerell.umaryland.edu/~jalemkul

==
--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.


Re: [gmx-users] Reproducibility in free energy calculations.

2014-04-19 Thread Michael Shirts
Mean of the three calculations is 4.35, standard error is 0.19.  So this
seems statistically consistent.  If you want to get more consistent
results, you'll need to run longer until the estimated statistical
uncertainty is lower.  Also, the estimated uncertainty is often an
underestimate (BAR often underestimates by 20-30%).


On Sat, Apr 19, 2014 at 9:05 AM, Justin Lemkul jalem...@vt.edu wrote:



 On 4/19/14, 1:16 AM, sujithkakkat . wrote:

 Hello Justin,

 I tried the free energy calculations in your tutorial at different
 sets
 of conditions. Also I repeated a simulation at the same conditions with
 same parameters, thrice on the same computer on same number of processors.
 The results in the three cases where different (4.16 +/- 0.19 , 4.36
 +/-0.14 , 4.54 +/-0.15 kJ/mol ) . I am not surprised, since I thought that
 this might happen to a small system (241 water + 1 methane). However, I
 want to be sure that this is OK. I guess in cases like this I should go
 for
 an average value of many runs.


 Offhand, I would have expected slightly better agreement between the runs,
 but there are tons of factors at play, so the outcome seems very plausible
 and reasonably consistent.

 -Justin

 --
 ==

 Justin A. Lemkul, Ph.D.
 Ruth L. Kirschstein NRSA Postdoctoral Fellow

 Department of Pharmaceutical Sciences
 School of Pharmacy
 Health Sciences Facility II, Room 601
 University of Maryland, Baltimore
 20 Penn St.
 Baltimore, MD 21201

 jalem...@outerbanks.umaryland.edu | (410) 706-7441
 http://mackerell.umaryland.edu/~jalemkul

 ==

 --
 Gromacs Users mailing list

 * Please search the archive at http://www.gromacs.org/
 Support/Mailing_Lists/GMX-Users_List before posting!

 * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

 * For (un)subscribe requests visit
 https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or
 send a mail to gmx-users-requ...@gromacs.org.

-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.


[gmx-users] about tutorial on virtual sites

2014-04-19 Thread sujithkakkat .
Hello Justin,

  I found that in  the virtual sites section of your tutorial, the energy
values of the system large positive . You had warned in the topology file
that the choice of the partial charges used are not guaranteed to work
always with OPLSAA . However, the momentum of inertial values points
indicate proper dynamics of the system.

Is the positive potential energy an out come of using the OPLSAA forcefield
? Is it normal to have positive potential energy?

Regards,

Sujith.
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.


[gmx-users] running parallel simulations on different of cores

2014-04-19 Thread Muthukumaran R
Dear gromacs users,
I have been working on gromacs package for performing md simulations.
recently i have started using cluster with 2 nodes with 64 cores each.
I am eager to know whether a job run on 32 cores for few ns and later i
continue the same job on 64 cores (or vice versa),  will show any
difference in the results in terms of energies or the  conformational
changes.

thanks in advance
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.


[gmx-users] Specifying the number of OpenMP threads that g_hbond uses

2014-04-19 Thread Andrew DeYoung
Hi, 

From the web page

http://www.gromacs.org/About_Gromacs/Release_Notes/Versions_4.6.x ,

it looks like parallelization for g_hbond (via OpenMP) was added in version
4.6.x.

What is a typical command to run g_hbond in parallel?  Since I mostly have
experience with Gromacs 4.5.5 (which for mdrun has auto MPI threading as the
default parallelization, which means I only have to specify the number of
threads with -nt), I am not sure how to launch OpenMP for g_hbond in 4.6.x.


When I just run g_hbond in 4.6.1 with no extra flags, the output says,
Frame loop parallelized with OpenMP using 8 threads.  Is there any way to
change the number of OpenMP threads that g_hbond uses?

Thanks so much!

Andrew DeYoung
Carnegie Mellon University

-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.


[gmx-users] how to fix center of mass

2014-04-19 Thread Tom
Dear Gromacs Users,

I am simulating a polymer membrane, which has two boxes of water on both
sides.

Polymer membrane position is shifting a lot even though I used comm_mode =
linear

Is there a way to fix the center of the mass of polymer membrane?

Thanks a lot for the suggestions!

Thom
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.


[gmx-users] GCMC?

2014-04-19 Thread Tom
Dear Gromacs Developers

Can some gromacs new version do Grand Canonical Monte Carlo (GCMC)
simulations?

Thanks!

Thomas
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.


Re: [gmx-users] GCMC?

2014-04-19 Thread Mark Abraham
No
On Apr 19, 2014 8:17 PM, Tom dna...@gmail.com wrote:

 Dear Gromacs Developers

 Can some gromacs new version do Grand Canonical Monte Carlo (GCMC)
 simulations?

 Thanks!

 Thomas
 --
 Gromacs Users mailing list

 * Please search the archive at
 http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before
 posting!

 * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

 * For (un)subscribe requests visit
 https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or
 send a mail to gmx-users-requ...@gromacs.org.

-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.


Re: [gmx-users] about tutorial on virtual sites

2014-04-19 Thread Justin Lemkul



On 4/19/14, 11:06 AM, sujithkakkat . wrote:

Hello Justin,

   I found that in  the virtual sites section of your tutorial, the energy
values of the system large positive . You had warned in the topology file
that the choice of the partial charges used are not guaranteed to work
always with OPLSAA . However, the momentum of inertial values points
indicate proper dynamics of the system.

Is the positive potential energy an out come of using the OPLSAA forcefield
? Is it normal to have positive potential energy?



Yes, that is normal.  Most gas-phase simulations will have a positive energy.

-Justin

--
==

Justin A. Lemkul, Ph.D.
Ruth L. Kirschstein NRSA Postdoctoral Fellow

Department of Pharmaceutical Sciences
School of Pharmacy
Health Sciences Facility II, Room 601
University of Maryland, Baltimore
20 Penn St.
Baltimore, MD 21201

jalem...@outerbanks.umaryland.edu | (410) 706-7441
http://mackerell.umaryland.edu/~jalemkul

==
--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.