Re: [gmx-users] Simulating different pH values of water
Hi Tsjerk,Thanks for your reply. I want to study the effect of pH on the wetting behaviour of water nanodroplet on graphene, the contact angle especially.For acidic solution, H and Cl ions are included in the water model, whereas for a high pH solution, there will be Na and OH ions, for instance.I am aware that a lot of quantum mechanics studies have been put into obtaining the H2O-carbon interaction properties with MP2 level accuracy.Using polarisable force field in this case might capture the properties of the charged ions, however, I am concerned if this approach is appropriate.Any feedback is greatly appreciated.Regards,Kester- 원본 메일 -보낸사람 : Tsjerk Wassenaar tsje...@gmail.com받는사람 : Discussion list for GROMACS us gmx-us...@gromacs.org받은날짜 : 2014년 8월 21일(목) 14:37:55제목 : Re: [gmx-users] Simulating different pH values of waterHi Kester, You do realize that water is odd quantum stuff, with oxygens going about in a sea of protons? The main way to move a free proton is to rewire the O-H bonds. What effects do you want investigate with your simulations? That determines what setup you need. Cheers, Tsjerk On Aug 21, 2014 6:46 AM, "Kester Wong"wrote: Dear all, This might not be relevant to MD technicalities, but I guess I should give it a shot. I would like to simulate water droplets at different pH values. However, knowing that a realistic system would need 180k water molecules to mimic a pH of 7. Is there another viable approach that I can use to simulate water droplets from low to high pH values? The original question was posted here: https://www.researchgate.net/post/How_can_I_calculate_the_number_of_molecules_with_respect_to_the_pH-value_in_solution?_tpcectx=subscription_feed#53f576d7d4c11805568b469c Regards, Kester -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] Error using pdb2gmx tool
hi, I was simulating A cadherin molecule (PDB ID: 4APX). I removed all the water molecule from molecule then ran the following command. pdb2gmx -f 4APX.pdb -water tip3p then I chose force field : CHARMM27 (with CMAP) after that it should create 3 types of files (.gro, .itp, .top) but it is not generating the .gro file and showing an error. Fatal error: Residue 'CA' not found in residue topology database. Please help me to solve this error. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] CUDA5.5 and ICC 14
Thanks! On 8/20/2014 8:03 PM, Mark Abraham wrote: Hi, Per Nvidia's docs and that error, CUDA 5.5 is only supported with that icc version. In practice, I understand that other icc versions work fine with GROMACS, but you would need to go and comment out that #error message. Alternatively, CUDA 6.5 supports icc 14.0 (only). Mark On Wed, Aug 20, 2014 at 8:26 AM, Theodore Si sjyz...@gmail.com wrote: Hi, I am using CUDA 5.5 and Intel ICC 14.0.1 to compile GROMACS and this happened: [ 0%] Building NVCC (Device) object src/gromacs/gmxlib/gpu_utils/ CMakeFiles/gpu_utils.dir//./gpu_utils_generated_gpu_utils.cu.o In file included from /usr/local/cuda-5.5/include/cuda_runtime.h(59), from /home/theo/gromacs-5.0/src/gromacs/gmxlib/gpu_utils/ gpu_utils.cu(0): /usr/local/cuda-5.5/include/host_config.h(72): catastrophic error: #error directive: -- unsupported ICC configuration! Only ICC 12.1 on Linux x86_64 is supported! #error -- unsupported ICC configuration! Only ICC 12.1 on Linux x86_64 is supported! ^ CMake Error at gpu_utils_generated_gpu_utils.cu.o.cmake:198 (message): Error generating /home/theo/gromacs-5.0/build/src/gromacs/gmxlib/gpu_utils/ CMakeFiles/gpu_utils.dir//./gpu_utils_generated_gpu_utils.cu.o make[2]: *** [src/gromacs/gmxlib/gpu_utils/CMakeFiles/gpu_utils.dir/./ gpu_utils_generated_gpu_utils.cu.o] Error 1 make[1]: *** [src/gromacs/gmxlib/gpu_utils/CMakeFiles/gpu_utils.dir/all] Error 2 make: *** [all] Error 2 Does this mean that I cannot make them work together? BR, Theo -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/ Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Install errors
Thanks! 2014-08-20 14:05 GMT+02:00 Mark Abraham mark.j.abra...@gmail.com: Hi, You should be using a supported host compiler for your version of CUDA (check its docs, probably gcc 4.7 or 4.8, for example), rather than clang. Mark On Wed, Aug 20, 2014 at 9:59 AM, Valentina Loconte valentina.loco...@studenti.unipd.it wrote: Hi, I'm trying to install the gromacs version 4.6.5. with the Quick and dirty installation. When I give the command make the platform gives me back this message of error: clang: error: unsupported option '-dumpspecs' clang: error: no input files CMake Error at gpu_utils_generated_memtestG80_core.cu.o.cmake:206 (message): Error generating /Users/Valentina/Software/gromacs-4.6.6/build/src/gmxlib/gpu_utils/CMakeFiles/gpu_utils.dir//./gpu_utils_generated_memtestG80_core.cu.o make[2]: *** [src/gmxlib/gpu_utils/CMakeFiles/gpu_utils.dir/./gpu_utils_generated_memtestG80_core.cu.o] Error 1 make[1]: *** [src/gmxlib/gpu_utils/CMakeFiles/gpu_utils.dir/all] Error 2 make: *** [all] Error 2 How may I avoid this problem? Thanks, Valentina -- Valentina Loconte, PhD student Department of Biomedical Sciences University of Padova Viale G. Colombo 3 35131 Padova, Italy -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Valentina Loconte, PhD student Department of Biomedical Sciences University of Padova Viale G. Colombo 3 35131 Padova, Italy -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Error using pdb2gmx tool
On 8/21/14, 5:24 AM, ankit agrawal wrote: hi, I was simulating A cadherin molecule (PDB ID: 4APX). I removed all the water molecule from molecule then ran the following command. pdb2gmx -f 4APX.pdb -water tip3p then I chose force field : CHARMM27 (with CMAP) after that it should create 3 types of files (.gro, .itp, .top) but it is not generating the .gro file and showing an error. Fatal error: Residue 'CA' not found in residue topology database. Calcium ions are called CAL in CHARMM. Rename the residue(s) in the .pdb file. -Justin -- == Justin A. Lemkul, Ph.D. Ruth L. Kirschstein NRSA Postdoctoral Fellow Department of Pharmaceutical Sciences School of Pharmacy Health Sciences Facility II, Room 601 University of Maryland, Baltimore 20 Penn St. Baltimore, MD 21201 jalem...@outerbanks.umaryland.edu | (410) 706-7441 http://mackerell.umaryland.edu/~jalemkul == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Forcefield parameters for Zinc and phosphorylated residues
Hi, QM parameterisation is how people tend to have done it for things like copper-bound proteins with GROMOS. I have been recently simulating one of these copper-bound proteins using a GROMOS force field (and indeed an AMBER force field too). I can send you a couple of papers regarding the GROMOS parameterisation for this protein off list if you like, so you can at least see their parameterisation methods for the copper centre? Cheers Tom From: gromacs.org_gmx-users-boun...@maillist.sys.kth.se [gromacs.org_gmx-users-boun...@maillist.sys.kth.se] on behalf of Michael Carter [michael.car...@icr.ac.uk] Sent: 21 August 2014 13:10 To: gmx-us...@gromacs.org Subject: Re: [gmx-users] Forcefield parameters for Zinc and phosphorylated residues Hi Tom, Thanks, I will look into it. I know AMBER has the ZAFF forcefield, and I have done the simulation in AMBER, but I wanted to know if GROMOS forcefields have this capability. I will have a play and see what I can do, most likely I will do a small QM/MM run and use this to parameterise the Zinc ions. Thanks for the help. Cheers, Mike From: gromacs.org_gmx-users-boun...@maillist.sys.kth.se [gromacs.org_gmx-users-boun...@maillist.sys.kth.se] On Behalf Of Piggot T. [t.pig...@soton.ac.uk] Sent: Wednesday, August 20, 2014 4:46 PM To: gmx-us...@gromacs.org Subject: Re: [gmx-users] Forcefield parameters for Zinc and phosphorylated residues Hi Mike, As well as the link that Bipin sent, you can also get parameters for GROMOS phosphorylated residues (compatible with the 43A1 force field, I think) from: http://www.gromacs.org/Downloads/User_contributions/Force_fields I've never used either so have no idea which might be better. The ones that Binpin suggested look like they work with the newer GROMOS 54A7 force field, so they might be the ones to use. On your other question, I am not sure about the protein-zinc parameters with a GROMOS force field. I would say, is there any particular need for using one of the GROMOS protein force fields? There are definitely parameters out there for some of the all-atom protein force fields (e.g. AMBER ones) which are probably also better in terms of protein parameters. Cheers Tom PS: Hope things are good in the (relatively) new job! From: gromacs.org_gmx-users-boun...@maillist.sys.kth.se [gromacs.org_gmx-users-boun...@maillist.sys.kth.se] on behalf of Michael Carter [michael.car...@icr.ac.uk] Sent: 20 August 2014 12:56 To: gmx-us...@gromacs.org Subject: Re: [gmx-users] Forcefield parameters for Zinc and phosphorylated residues Hi Bipin, Thanks for this. It works well for adding functionality to residues. Cheers, Mike Carter On 20/08/2014 12:10, bipin singh bipinel...@gmail.com wrote: This might help. http://vienna-ptm.univie.ac.at/ *Thanks and Regards,Bipin Singh* On Wed, Aug 20, 2014 at 4:30 PM, Michael Carter michael.car...@icr.ac.uk wrote: Hi, I have two questions regarding the parameterisation of Zinc ions and a phosphorylated TYR residue within two different protein systems. 1. Zinc parameters: I have three zinc ions within one protein system. I want to use a bonded model so that they do not fly out of my protein upon simulation. Is there any documentation on the parameters for such a model in the GROMOS forcefield? 2. Phosphorylated TYR In another system I have a phosphorylated TYR residue. PDB2GMX does not like this and after looking inot the manual I have found that you can add parameters for this to the existing forcefields. Much like the previous question, is there any documentation on the addition of parameters for phosphorylated residues in the GROMOS forcefield? Any pointers for these questions would be greatly appreciated. Cheers, Mike Carter The Institute of Cancer Research: Royal Cancer Hospital, a charitable Company Limited by Guarantee, Registered in England under Company No. 534147 with its Registered Office at 123 Old Brompton Road, London SW7 3RP. This e-mail message is confidential and for use by the addressee only. If the message is received by anyone other than the addressee, please return the message to the sender by replying to it and then delete the message from your computer and network. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit
[gmx-users] How invoke hamiltonian replica exchange in 4.6.5
Dear gmx users: I got a problem that I could not invoke hamiltonian replica exchange in version 4.6.5. I've different lambda value for each replica ( free_energy = yes; init-lambda = 0.X ) however I got error the properties of the 4 systems arre all the same... I've tried the method suggested in https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2013-August/083425.html , however after add fep-lambdas = 0.X I still get same error. I'm checking src/kernel/repl_ex.c and found if my systems are assigned to hamiltonian replica exchange, it should report Replica exchange in lambda to log file ( around l299), and in my log file it has Replica exchange in temperature so it shows I failed at invoke hamiltonian replica exchange. I just wonder would any one like to tell me how to invoke hamiltonian replica exchange in 4.6.5 (or other 4.6 version)? Thank you! Yours Guang -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Several questions about log file.
On Thu, Aug 21, 2014 at 7:57 AM, Theodore Si sjyz...@gmail.com wrote: Hi, 1. Does force in the R E A L C Y C L E A N D T I M E A C C O U N T I N G table mean the time spent on short-range force calculation? and bonded interactions. 2. Does Comm. coord mean the communication of atom positions when calculating short-range force interaction? As I've said before, the entries in this table correspond to sections in the DD-PME flowchart in figure 3.16 of the manual. It's not 1-to-1, but the correspondence is fairly clear. As you can see there, there can be two kinds of communication of position coordinates required. So the answer to your question is yes but there can be more to it. 3. What forces are waited and communicated in Wait + Comm. F? Real-space forces from DD neighbours, per flowchart. Each node of our cluster has two Intel(R) Xeon(R) CPU E5-2670 0 @ 2.60GHz, each has 8 cores. When we are using 2 nodes, that is 2nodes * 2 cpus * 8 cores = 32 cores, we will be Using 32 MPI processes Using 1 OpenMP thread per MPI proces and Comm. coord. 241 19200 1.483 92.327 1.0 1.483s are spent on the coordinate communication When we are using 32 nodes, that is 32nodes * 2 cpus * 8 cores = 32 cores, we will be Using 512 MPI processes Using 1 OpenMP thread per MPI proces and Comm. coord. 3841 19200 2.094 2086.377 5.2 2.094s are spent on the coordinate communication 4. Why the time spent on communication of coordinate doesn't scale up as the cores are increasing Someone coded it right ;-) The implementation is talked about in manual 3.17.1. The total volume of communication does increase as there are more domains(=ranks), but only communication between different nodes will have an effect (to first order). The actual performance properties will depend on the qualities of your network, but the total amount of coordinate data transferred (three 4-byte floats per ~100 atoms per domain-pair) is tiny compared with what typical networks are designed to handle, so the total cost of the communication will be dominated by the latency of just sending a message. The number of domain-pairs sending messages has gone up, of course, but your results show that the cost is still dominated by latency (which is not news, of course, hiding such latencies is key for improving strong scaling of MD). Mark BR, Theo -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/ Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] REMD tutorial
On Thu, Aug 21, 2014 at 8:01 AM, shahab shariati shahab.shari...@gmail.com wrote: Dear Mark Before, in following address you said: Google knows about two GROMACS REMD tutorials. https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2014-January/086563.html Unfortunately, I could not find tutorials you mentioned. You can find them here https://www.google.se/search?q=gromacs+remd+tutorialsoq=gromacs+remd+tutorials Also, in following address you said: I've added a section on replica-exchange to http://wiki.gromacs.org/index.php/Steps_to_Perform_a_Simulation https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2007-December/031188.html . Is this link active, now? I have no access to this link. The webpage has been changed since then, see link from http://www.gromacs.org/Documentation/How-tos/Steps_to_Perform_a_Simulation Mark - I want to know Is there a tutorial for REMD like what is in http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin/gmx-tutorials/. Any help will highly appreciated. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] How invoke hamiltonian replica exchange in 4.6.5
Are your temperatures the same in each replica? Mark On Thu, Aug 21, 2014 at 4:08 PM, jia jia jzg...@gmail.com wrote: Dear gmx users: I got a problem that I could not invoke hamiltonian replica exchange in version 4.6.5. I've different lambda value for each replica ( free_energy = yes; init-lambda = 0.X ) however I got error the properties of the 4 systems arre all the same... I've tried the method suggested in https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2013-August/083425.html , however after add fep-lambdas = 0.X I still get same error. I'm checking src/kernel/repl_ex.c and found if my systems are assigned to hamiltonian replica exchange, it should report Replica exchange in lambda to log file ( around l299), and in my log file it has Replica exchange in temperature so it shows I failed at invoke hamiltonian replica exchange. I just wonder would any one like to tell me how to invoke hamiltonian replica exchange in 4.6.5 (or other 4.6 version)? Thank you! Yours Guang -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] regarding MSD
Hello all I have read few papers that determine transition temperature from the plot of average MSD versus temperature. My question is: At a particular temperature, we get a linear curve for MSD versus time, is it reasonable to calculate average MSD over all such time points? Is this the average that is plotted in papers (or something is missing) ? My doubt is won't this average depend on the number of time points (due to its linear nature)? Any help is highly appreciated. Thanks Nidhi -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Extending simulation problem.
Well in my *log file nothing about state or *cpi files is mentioned. Acutally I have a question regarding state.cpi files. Does it contain names of *gro, *trr, etc. files if they are not standard? The thing is, that output files from my first 5ns simulation are not standard. Now, I perform these calculations not in my working directory but on separate scratch. In this case, should the output files from previous simulation be present in the scratch? And when I run another 5 ns should I run mdrun with those -c -o and -e options? If yes, should the names of files be the same as in the previous simulation? 2014-08-20 18:18 GMT+01:00 Justin Lemkul jalem...@vt.edu: On 8/20/14, 6:33 AM, Dawid das wrote: Dear Gromacs experts, I googled for answer and I found these: http://www.gromacs.org/Documentation/How-tos/Extending_Simulations http://www.researchgate.net/post/How_to_extend_the_ protein_simulation_in_Gromacs_from_1000_ps_to_1_ps but still I am confused about what happens in my simulation. I did 5 ns simulation and I would like to add extra 5 ns on top of that so that new results (energies, temperature, trajectory, etc.) will be appended to already existing files after first 5 ns simulation. Now I used this command to run MD simulation for the first time: \$MDRUN -v -s npt-md.tpr -o mCherry7-npt-md.trr -c mCherry7-npt-md.gro -e mCherry7-npt-md.edr $CURDIR/mCherry7-npt-md.log 21 After this in the same directory I run: tpbconv -s npt-md.tpr -extend 5000 -o npt-md-ext.tpr \$MDRUN -s npt-md-ext.tpr -cpi state.cpt I tried both state.cpt and prev_state.cpt and the beginning of new simulation looks exactly the same that means temperature, energies, etc. are the same as if I started from 0ns step, not from 5ns step of previous simulation. What can cause that? Is it because of used files names or I did something else wrong? What does the .log file say? It should clearly indicate if the restart was done by reading in the checkpoint file. -Justin -- == Justin A. Lemkul, Ph.D. Ruth L. Kirschstein NRSA Postdoctoral Fellow Department of Pharmaceutical Sciences School of Pharmacy Health Sciences Facility II, Room 601 University of Maryland, Baltimore 20 Penn St. Baltimore, MD 21201 jalem...@outerbanks.umaryland.edu | (410) 706-7441 http://mackerell.umaryland.edu/~jalemkul == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/ Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Numerical Stability of Gromacs Implementation
Sorry for asking this. Is it possible for me to get some references about the claims of instability of gromacs simulations, and their debunk? From the few papers that I read, I guess algorithms of molecular dynamics do not treat all observables equally well. Some old papers say that the velocity in velocity verlet is not symplectic, but rather follows some shadow hamiltonian or generalized equipartition theorem. Then another one mentioned force splitting can reduce the resonance effect caused by integrator. That said, very few papers talk about this. I don't know much about the effect of MD on the observables that I try to look at. And, sorry for replying this late, I have been installing gromacs on aix for a week. Compiling gcc took 3 days of computer time. On Thu, Aug 14, 2014 at 2:29 PM, Mark Abraham mark.j.abra...@gmail.com wrote: On Wed, Aug 13, 2014 at 1:19 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi again. Some of my friends said that gromacs had lower numerical stability than amber, and occasionally has mysterious error in energy. Show us a result and we'll discuss fixing it ;-) Is that still true? Does the implementation of Integrator cause more resonance effect? Any numerical software can be used poorly. Any numerical software can have bugs. Give them the same input to two implementations of the same algorithm and they should give results that are similar (whatever that means in the problem domain). I am trying to run NVE simulation with the single precision version, and so I guess the implementation of thermostats is not my most immediate concern at the moment. I searched online, and haven't found much about numerical instability of gromacs using amber forcefield (I mean for version 4.6, which supports the amber force-fields without modification.) What do you mean by numerical stability? Should you actually be concerned about getting a correct physical observable? People look at energy conservation because it is easy to do, but connecting that to the quality of the resulting physics is non-trivial. Even if you can (say) deliver state-of-the-art energy conservation (and most packages can do this in some mode), you still need to measure the price in simulation throughput incurred by running in that mode. The overall objective is to deliver science of sufficient quality with minimal time to solution. In some cases, it is right to let some energy leak and let the thermostat fix it, if you generate many more samples by so doing. Why do people still use and paid for amber, when gromacs is free? I look online and the number of papers that use amber is about twice of the number of paper that use gromacs. There are very few papers that mentioned both gromacs and amber. Inertia is a big effect. You tend to adopt the package used by the local MD expert so you have a low-latency person of whom to ask questions. They tend to still use the package they used in their doctoral work, regardless of current technical merit, because learning to use such software well is tricky and discarding your old workflows is not a cheap proposition. The next biggest effect is what functionality is available, and at what performance. Mark Thank you. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] [gmx-developers] About dynamics loading balance
Hi, On Thu, Aug 21, 2014 at 1:56 PM, Yunlong Liu yliu...@jh.edu wrote: Hi Roland, The problem I am posting is caused by trivial errors (like not enough memory) and I think it should be a real bug inside the gromacs-GPU support code. It is unlikely a trivial error because otherwise someone else would have noticed. You could try the release-5-0 branch from git, but I'm not aware of any bugfixes related to memory allocation. The memory allocation which causes the error isn't the problem. The printed size is reasonable. You could recompile with PRINT_ALLOC_KB (add -DPRINT_ALLOC_KB to CMAKE_C_FLAGS) and rerun the simulation. It might tell you where the usual large memory allocation happens. PS: Please don't reply to an individual Gromacs developer. Keep all conversation on the gmx-users list. Roland That is the reason why I post this problem to the developer mailing-list. My system contains ~240,000 atoms. It is a rather big protein. The memory information of the node is : top - 12:46:59 up 15 days, 22:18, 1 user, load average: 1.13, 6.27, 11.28 Tasks: 510 total, 2 running, 508 sleeping, 0 stopped, 0 zombie Cpu(s): 6.3%us, 0.0%sy, 0.0%ni, 93.7%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 32815324k total, 4983916k used, 27831408k free, 7984k buffers Swap: 4194296k total,0k used, 4194296k free, 700588k cached I am running the simulation on 2 nodes, 4 MPI ranks and each rank with 8 OPENMP-threads. I list the information of their CPU and GPU here: c442-702.stampede(1)$ nvidia-smi Thu Aug 21 12:46:17 2014 +--+ | NVIDIA-SMI 331.67 Driver Version: 331.67 | |---+--+--+ | GPU NamePersistence-M| Bus-IdDisp.A | Volatile Uncorr. ECC | | Fan Temp Perf Pwr:Usage/Cap| Memory-Usage | GPU-Util Compute M. | |===+==+==| | 0 Tesla K20m Off | :03:00.0 Off |0 | | N/A 22CP046W / 225W |172MiB / 4799MiB | 0% Default | +---+--+--+ +-+ | Compute processes: GPU Memory | | GPU PID Process name Usage | |=| |0113588 /work/03002/yliu120/gromacs-5/bin/mdrun_mpi 77MiB | |0113589 /work/03002/yliu120/gromacs-5/bin/mdrun_mpi 77MiB | +-+ c442-702.stampede(4)$ lscpu Architecture: x86_64 CPU op-mode(s):32-bit, 64-bit Byte Order:Little Endian CPU(s):16 On-line CPU(s) list: 0-15 Thread(s) per core:1 Core(s) per socket:8 Socket(s): 2 NUMA node(s): 2 Vendor ID: GenuineIntel CPU family:6 Model: 45 Stepping: 7 CPU MHz: 2701.000 BogoMIPS: 5399.22 Virtualization:VT-x L1d cache: 32K L1i cache: 32K L2 cache: 256K L3 cache: 20480K NUMA node0 CPU(s): 0-7 NUMA node1 CPU(s): 8-15 I hope this information will help. Thank you. Yunlong On 8/21/14, 1:38 PM, Roland Schulz wrote: Hi, please don't use gmx-developers for user questions. Feel free to use it if you want to fix the problem, and have questions about implementation details. Please provide more details: How large is your system? How much memory does a node have? On how many nodes do you try to run? How many mpi-ranks do you have per node? Roland On Thu, Aug 21, 2014 at 12:21 PM, Yunlong Liu yliu...@jh.edu wrote: Hi Gromacs Developers, I found something about the dynamic loading balance really interesting. I am running my simulation on Stampede supercomputer, which has nodes with 16-physical core ( really 16 Intel Xeon cores on one node ) and an NVIDIA Tesla K20m GPU associated. When I am using only the CPUs, I turned on dynamic loading balance by -dlb yes. And it seems to work really good, and the loading imbalance is only 1~2%. This really helps improve the performance by 5~7%。But when I am running my code on GPU-CPU hybrid ( GPU node, 16-cpu and 1 GPU), the dynamic loading balance kicked in since the imbalance goes up to ~50% instantly after loading. Then the the system reports a fail-to-allocate-memory error: NOTE: Turning on dynamic load balancing --- Program mdrun_mpi, VERSION 5.0 Source code file: /home1/03002/yliu120/build/gromacs-5.0/src/gromacs/utility/smalloc.c, line: 226 Fatal error: Not enough memory. Failed to realloc
[gmx-users] GROMACS version 5.0 incompatible with my hardware - help req
Dear Users I initially installed GROMACS 5.0 in my office computer and tried running a few sample tutorials over there. It was showing a illegal instruction : core dumped error. On searching the archived files in the user group I found that the version of GROMACS installed in my computer is not compatible with the hardware. So I have uninstalled all the GROMACS files one by one using the command : sudo rm -rf /usr/bin/gromacs command My computer hardware configuration is : - (A) Intel Core 2 CPU 6600 @ 2.40 GHz x 2 (B) 2.0 GB RAM DDR2 My OS is ubuntu 14.04 LTS 64-Bit Could anyone please tell me what version of GROMACS I should try installing ?? Thanks Regards Agnivo Gosai Graduate Student Mechanical Engineering Iowa State University -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] GROMACS version 5.0 incompatible with my hardware - help req
where did you get gromacs? how did you install it? (like you compile it yourself, or you get the package with apt-get?) On Thu, Aug 21, 2014 at 3:11 PM, Agnivo Gosai agnivo2...@gmail.com wrote: Dear Users I initially installed GROMACS 5.0 in my office computer and tried running a few sample tutorials over there. It was showing a illegal instruction : core dumped error. On searching the archived files in the user group I found that the version of GROMACS installed in my computer is not compatible with the hardware. So I have uninstalled all the GROMACS files one by one using the command : sudo rm -rf /usr/bin/gromacs command My computer hardware configuration is : - (A) Intel Core 2 CPU 6600 @ 2.40 GHz x 2 (B) 2.0 GB RAM DDR2 My OS is ubuntu 14.04 LTS 64-Bit Could anyone please tell me what version of GROMACS I should try installing ?? Thanks Regards Agnivo Gosai Graduate Student Mechanical Engineering Iowa State University -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] GROMACS version 5.0 incompatible with my hardware - help req
or.. you get it from some rpm/deb binary file that is for another kind of cpu? On Thu, Aug 21, 2014 at 3:44 PM, Johnny Lu johnny.lu...@gmail.com wrote: where did you get gromacs? how did you install it? (like you compile it yourself, or you get the package with apt-get?) On Thu, Aug 21, 2014 at 3:11 PM, Agnivo Gosai agnivo2...@gmail.com wrote: Dear Users I initially installed GROMACS 5.0 in my office computer and tried running a few sample tutorials over there. It was showing a illegal instruction : core dumped error. On searching the archived files in the user group I found that the version of GROMACS installed in my computer is not compatible with the hardware. So I have uninstalled all the GROMACS files one by one using the command : sudo rm -rf /usr/bin/gromacs command My computer hardware configuration is : - (A) Intel Core 2 CPU 6600 @ 2.40 GHz x 2 (B) 2.0 GB RAM DDR2 My OS is ubuntu 14.04 LTS 64-Bit Could anyone please tell me what version of GROMACS I should try installing ?? Thanks Regards Agnivo Gosai Graduate Student Mechanical Engineering Iowa State University -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] GROMACS version 5.0 incompatible with my hardware - help req
On 8/21/14, 3:11 PM, Agnivo Gosai wrote: Dear Users I initially installed GROMACS 5.0 in my office computer and tried running a few sample tutorials over there. It was showing a illegal instruction : core dumped error. On searching the archived files in the user group I found that the version of GROMACS installed in my computer is not compatible with the hardware. It's not the version of Gromacs, per se, it's the level of optimization. So I have uninstalled all the GROMACS files one by one using the command : sudo rm -rf /usr/bin/gromacs command My computer hardware configuration is : - (A) Intel Core 2 CPU 6600 @ 2.40 GHz x 2 (B) 2.0 GB RAM DDR2 My OS is ubuntu 14.04 LTS 64-Bit Could anyone please tell me what version of GROMACS I should try installing ?? What level of optimization (GMX_SIMD during cmake) was set before? What does cmake detect on its own if GMX_SIMD is not explicitly set? What compilers (and versions) are you using to compile? -Justin -- == Justin A. Lemkul, Ph.D. Ruth L. Kirschstein NRSA Postdoctoral Fellow Department of Pharmaceutical Sciences School of Pharmacy Health Sciences Facility II, Room 601 University of Maryland, Baltimore 20 Penn St. Baltimore, MD 21201 jalem...@outerbanks.umaryland.edu | (410) 706-7441 http://mackerell.umaryland.edu/~jalemkul == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
[gmx-users] pressure after NPT
dear gromacs users, I am simulating Carbon nanotubes in water. I did the NPT simulation with a reference pressure of 1 bar. When I do an NPT simulation for about 100 ps, the system shows an average pressure of 1.4 bar. So i thought a longer NPT simulation would give me a better average pressure. But when i did an NPT for 200ps, the average pressure was increased to 1.85 bar. what can I do to improve my average pressure conditions? -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] pressure after NPT
On 8/21/14, 4:22 PM, ibrahim khalil wrote: dear gromacs users, I am simulating Carbon nanotubes in water. I did the NPT simulation with a reference pressure of 1 bar. When I do an NPT simulation for about 100 ps, the system shows an average pressure of 1.4 bar. So i thought a longer NPT simulation would give me a better average pressure. But when i did an NPT for 200ps, the average pressure was increased to 1.85 bar. what can I do to improve my average pressure conditions? http://www.gromacs.org/Documentation/Terminology/Pressure A few hundred ps is very little in terms of getting pressure to stabilize, but likely the differences you observe from the target value are not meaningful. -Justin -- == Justin A. Lemkul, Ph.D. Ruth L. Kirschstein NRSA Postdoctoral Fellow Department of Pharmaceutical Sciences School of Pharmacy Health Sciences Facility II, Room 601 University of Maryland, Baltimore 20 Penn St. Baltimore, MD 21201 jalem...@outerbanks.umaryland.edu | (410) 706-7441 http://mackerell.umaryland.edu/~jalemkul == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Numerical Stability of Gromacs Implementation
On Thu, Aug 21, 2014 at 7:59 PM, Johnny Lu johnny.lu...@gmail.com wrote: Sorry for asking this. Is it possible for me to get some references about the claims of instability of gromacs simulations, and their debunk? Not really. You can find a paper from some of the Desmond authors that correctly observes some issues in GROMACS 3.x. People occasionally refer to it here as if it is current news. These issues are long fixed, but not worth writing about - journal articles should be about delivering quality science. More commonly, an issue would be handled via private email, though even these are rare. Overall, the biomolecular MD community is quite good at finding problems with their own and each other's algorithms and implementations and getting them fixed constructively. People saying someone said x was bad but gave me no details need to talk to the someone, not just the authors of x ;-) If people start being evasive or secretive about possible problems with their code... be concerned. From the few papers that I read, I guess algorithms of molecular dynamics do not treat all observables equally well. Some old papers say that the velocity in velocity verlet is not symplectic, but rather follows some shadow hamiltonian or generalized equipartition theorem. This is common to all methods with a finite time step - see http://en.wikipedia.org/wiki/Energy_drift. There are certainly a variety of ways of estimating the velocity with common integrators, and they have different quality attributes. You can read about how GROMACS handles this in the manual. Then another one mentioned force splitting can reduce the resonance effect caused by integrator. That said, very few papers talk about this. There are lots of papers that discuss details of multiple time-stepping algorithms that seek to deal with this issue directly. I don't know much about the effect of MD on the observables that I try to look at. It's not an easy topic - generating converged sampling to assess whether an integration scheme correctly samples a complex observable is still a non-trivial matter. That needs to happen before questions of how much algorithmic energy drift is acceptable can be satisfactorily addressed. Until then, claims of my energy conservation is better than yours need to be considered alongside my number of independent converged-ensemble samples is better than yours. And, sorry for replying this late, I have been installing gromacs on aix for a week. Compiling gcc took 3 days of computer time. Seriously, don't bother. I don't think there is any system that would have AIX, with no gcc package available, and which GROMACS 5.0 would run decently on (which would require SIMD support, which currently means x86 or BlueGene/Q). I'd guess your laptop will get equivalent performance. Mark On Thu, Aug 14, 2014 at 2:29 PM, Mark Abraham mark.j.abra...@gmail.com wrote: On Wed, Aug 13, 2014 at 1:19 PM, Johnny Lu johnny.lu...@gmail.com wrote: Hi again. Some of my friends said that gromacs had lower numerical stability than amber, and occasionally has mysterious error in energy. Show us a result and we'll discuss fixing it ;-) Is that still true? Does the implementation of Integrator cause more resonance effect? Any numerical software can be used poorly. Any numerical software can have bugs. Give them the same input to two implementations of the same algorithm and they should give results that are similar (whatever that means in the problem domain). I am trying to run NVE simulation with the single precision version, and so I guess the implementation of thermostats is not my most immediate concern at the moment. I searched online, and haven't found much about numerical instability of gromacs using amber forcefield (I mean for version 4.6, which supports the amber force-fields without modification.) What do you mean by numerical stability? Should you actually be concerned about getting a correct physical observable? People look at energy conservation because it is easy to do, but connecting that to the quality of the resulting physics is non-trivial. Even if you can (say) deliver state-of-the-art energy conservation (and most packages can do this in some mode), you still need to measure the price in simulation throughput incurred by running in that mode. The overall objective is to deliver science of sufficient quality with minimal time to solution. In some cases, it is right to let some energy leak and let the thermostat fix it, if you generate many more samples by so doing. Why do people still use and paid for amber, when gromacs is free? I look online and the number of papers that use amber is about twice of the number of paper that use gromacs. There are very few papers that mentioned both gromacs and amber. Inertia is a big effect. You tend to adopt the package used by the local MD
Re: [gmx-users] too many lincs warnings
Thanks.. On Aug 20, 2014 1:29 PM, Meenakshi Rajput ashi.rajpu...@gmail.com wrote: hello users I had done energy minimisation of protein-ligand complex and i got negative potential. Also the ligand was at right place after EM run but when I tried the positional restrained run, too many lincs warnings came and md run stopped suddenly. I am using charmm force field and mdp file settings for position restrined run are:- define= -DPOSRES; position restrain the protein ; Run parameters integrator= md; leap-frog integrator nsteps= 5; 2 * 5 = 100 ps dt= 0.002; 2 fs ; Output control nstxout= 500; save coordinates every 0.2 ps nstvout= 500; save velocities every 0.2 ps nstenergy= 500; save energies every 0.2 ps nstlog= 500; update log file every 0.2 ps ; Bond parameters continuation= yes; first dynamics run constraint_algorithm = lincs; holonomic constraints constraints= all-bonds; all bonds (even heavy atom-H bonds) constrained lincs_iter= 1; accuracy of LINCS lincs_order= 4; also related to accuracy ; Neighborsearching cutoff-scheme = Verlet ns_type= grid; search neighboring grid cells nstlist= 10; 10 fs rlist= 1.2; short-range neighborlist cutoff (in nm) rcoulomb= 1.2; short-range electrostatic cutoff (in nm) rvdw= 1.2; short-range van der Waals cutoff (in nm) rvdw-switch = 1.0 ; Electrostatics coulombtype= PME; Particle Mesh Ewald for long-range electrostatics pme_order= 4; cubic interpolation fourierspacing= 0.16; grid spacing for FFT ; Temperature coupling is on tcoupl= V-rescale; modified Berendsen thermostat tc-grps= Protein Non-Protein; two coupling groups - more accurate tau_t= 0.10.1; time constant, in ps ref_t= 300 300; reference temperature, one for each group, in K ; Pressure coupling is off pcoupl= no ; no pressure coupling in NVT ; Periodic boundary conditions pbc= xyz; 3-D PBC ; Dispersion correction DispCorr= EnerPres; account for cut-off vdW scheme ; Velocity generation gen_vel= yes; assign velocities from Maxwell distribution gen_temp= 300; temperature for Maxwell distribution gen_seed= -1; generate a random seed Please tell me if there is something wrong with mdp settings or is it some other problem? -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Job Submission script for Multiple nodes GPUs calculation
Hi, On 22 Aug 2014, at 01:38, Xingcheng Lin linxingcheng50...@gmail.com wrote: Good afternoon, I am trying to use multiple nodes to do GPU simulation, each node has two GPUs and 12 CPUs mounted. Is there any submission script for doing that? For single node I used: mpiexec -np 2 mdrun_mpi -s run.tpr -cpi state.cpt -cpo state.cpt -noappend -gpu_id 01 -nb gpu -ntomp 6 For 2 nodes I cannot use the script like mpiexec -np 4 mdrun_mpi -s run.tpr -cpi state.cpt -cpo state.cpt -noappend -gpu_id 0123 -nb gpu -ntomp 6 The -gpu_id string refers to the GPU id’s _per node_, so you should also use -gpu_id 01 on two and more of these nodes. Best, Carsten Any suggestion about what I should do? Thank you, Arrow -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Dr. Carsten Kutzner Max Planck Institute for Biophysical Chemistry Theoretical and Computational Biophysics Am Fassberg 11, 37077 Goettingen, Germany Tel. +49-551-2012313, Fax: +49-551-2012302 http://www.mpibpc.mpg.de/grubmueller/kutzner http://www.mpibpc.mpg.de/grubmueller/sppexa -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Interteting flooding results
Hi, On 21 Aug 2014, at 23:27, Ricardo O. S. Soares rsoa...@fcfrp.usp.br wrote: Dear users, could anyone give me some general guidelines or links to help me interpret the essential dynamics/flooding output xvg file from a flooding simulation? That depends a bit on which Gromacs Version you are using. If you are using a 4.6 or later version, look in the header of the .xvg file, there should be a short explanation about what is written to each column of the file. What columns are printed depend on what is switched on in your .edi file. Best, Carsten I followed Spiwok's tutorial (http://web.vscht.cz/~spiwokv/mtdec/index.html) and Langer's paper (http://onlinelibrary.wiley.com/doi/10.1002/jcc.20473/full) . Thanks, --- Biological Chemistry and Physics Faculty of Pharmaceutical Sciences at Ribeirão Preto University of São Paulo - Brazil -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org. -- Dr. Carsten Kutzner Max Planck Institute for Biophysical Chemistry Theoretical and Computational Biophysics Am Fassberg 11, 37077 Goettingen, Germany Tel. +49-551-2012313, Fax: +49-551-2012302 http://www.mpibpc.mpg.de/grubmueller/kutzner http://www.mpibpc.mpg.de/grubmueller/sppexa -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.