[gmx-users] Pressures after NPT

2014-08-06 Thread ibrahim khalil
dear gromacs users, I did an NPT equilibration of 100ps with a reference
pressure of 1bar. After the equilibration, my average pressure was 1.2 bar.
But when I started my production run (with a reference pressure of 1 bar)
my pressure was rising (and falling) again. for the first 50 ps, the
average pressure was -7.2 bar. Then after a 100ps of production run the
pressure was -0.84 bar.

I have two questions regrading this-

1. Does negative pressure mean anything wrong with my system? or should I
just take the magnitude of my pressure?

2. After the NPT my average pressure was rising again(but eventually came
close to its reference value after some time), should it happen in a stable
simulation?
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.


Re: [gmx-users] Pressures after NPT

2014-08-06 Thread Justin Lemkul



On 8/6/14, 4:54 AM, ibrahim khalil wrote:

dear gromacs users, I did an NPT equilibration of 100ps with a reference
pressure of 1bar. After the equilibration, my average pressure was 1.2 bar.
But when I started my production run (with a reference pressure of 1 bar)
my pressure was rising (and falling) again. for the first 50 ps, the
average pressure was -7.2 bar. Then after a 100ps of production run the
pressure was -0.84 bar.

I have two questions regrading this-

1. Does negative pressure mean anything wrong with my system? or should I
just take the magnitude of my pressure?



Positive and negative correspond to expansion and contraction.


2. After the NPT my average pressure was rising again(but eventually came
close to its reference value after some time), should it happen in a stable
simulation?



Pressure fluctuates wildly in a simulation.  See 
http://www.gromacs.org/Documentation/Terminology/Pressure.


-Justin

--
==

Justin A. Lemkul, Ph.D.
Ruth L. Kirschstein NRSA Postdoctoral Fellow

Department of Pharmaceutical Sciences
School of Pharmacy
Health Sciences Facility II, Room 601
University of Maryland, Baltimore
20 Penn St.
Baltimore, MD 21201

jalem...@outerbanks.umaryland.edu | (410) 706-7441
http://mackerell.umaryland.edu/~jalemkul

==
--
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.