Re: [gmx-users] lie calculations

2018-09-13 Thread Vytautas Rakeviius
 Hi I think you should check this paper:Åqvist J, Medina C, Samuelsson JE. A 
new method for predicting binding affinity in computer-aided drug design. 
Protein Engineering, Design and Selection. 1994 Mar 1;7(3):385-91.It explains 
everything and gives example of use.And yes with different water models you 
should expect more or less different results.
Also as you see those fitting coefficients in paper like 0.5 or alpha or beta 
etc. I suggest refitting with your own data-set water model force field etc. as 
those numbers depend on such things. That became clear far later after this 
original paper.
On Wednesday, September 12, 2018, 6:35:23 PM GMT+3, Graham Jackson 
 wrote:  
 
 Hi All
I have looked at the manual and can execute LIE but I want to understand the 
process.  The manual gives instructions but no background theory. The theory I 
have seen does not explain how GROMACS does the calculation.  I have a 
simulation of a ligand bound to a receptor embedded in a POPC membrane.  I also 
have a simulation of the ligand in water.  I use these two for the lie 
calculation.  Is this correct and does the choice of water (spc TIP3P Tip4P) 
matter?

Thanks
Graham



—
Professor Graham E Jackson
Department of Chemistry
University of Cape Town
South Africa
+27 21 650 2531

Disclaimer - University of Cape Town This email is subject to UCT policies and 
email disclaimer published on our website at 
http://www.uct.ac.za/main/email-disclaimer or obtainable from +27 21 650 9111. 
If this email is not related to the business of UCT, it is sent by the sender 
in an individual capacity. Please report security incidents or abuse via 
https://csirt.uct.ac.za/page/report-an-incident.php.
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.  
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.

[gmx-users] lie calculations

2018-09-12 Thread Graham Jackson
Hi All
I have looked at the manual and can execute LIE but I want to understand the 
process.  The manual gives instructions but no background theory. The theory I 
have seen does not explain how GROMACS does the calculation.   I have a 
simulation of a ligand bound to a receptor embedded in a POPC membrane.  I also 
have a simulation of the ligand in water.  I use these two for the lie 
calculation.  Is this correct and does the choice of water (spc TIP3P Tip4P) 
matter?

Thanks
Graham



—
Professor Graham E Jackson
Department of Chemistry
University of Cape Town
South Africa
+27 21 650 2531

Disclaimer - University of Cape Town This email is subject to UCT policies and 
email disclaimer published on our website at 
http://www.uct.ac.za/main/email-disclaimer or obtainable from +27 21 650 9111. 
If this email is not related to the business of UCT, it is sent by the sender 
in an individual capacity. Please report security incidents or abuse via 
https://csirt.uct.ac.za/page/report-an-incident.php.
-- 
Gromacs Users mailing list

* Please search the archive at 
http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting!

* Can't post? Read http://www.gromacs.org/Support/Mailing_Lists

* For (un)subscribe requests visit
https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a 
mail to gmx-users-requ...@gromacs.org.