Re: [gmx-users] Ionic liquid simulation problem
I answered this the other day: https://mailman-1.sys.kth.se/pipermail/gromacs.org_gmx-users/2017-September/115865.html -Justin On 9/14/17 9:55 AM, Agatha Faria wrote: Dear GROMACS Community, I am very new with GROMACS I am trying to run a simulation of an ionic liquid (1-butyl-3-methyl-imidazolium and hexafluorophosphate) according to the following protocol: 1. Prepared the respective PDB files and added/modified the OPLS/AA force field parameters updating the atomtypes.atp, aminoacid.rtp, ffbonded.itp and ffnonbonded.itp files. 2. Used pdb2gmx command to create the respective .gro files, as well as, the posre.itp and topol.top files chossing OPLS/AA option without solvation. 3. Used the insert-molecules command to create a box filled with one specie (cation) and add the other specie (anion) into the same box. 4. Updated, by hand, the generated topol_box.top (pos_box.top) file including the topol.top and the posre.itp files of the other specie (anion) at the end of it. 5. Tried to used the grompp command to minimize the energy of the cations+anions box and got the following error: Fatal error: Too many warnings (18), gmx terminated. If you are sure all warnings are harmless, use the -maxwarn option. 6. Using a -maxwarn option got the following error: Error in user input: Invalid command-line options In command-line option -maxwarn Too few (valid) values Does anyone knows whats is wrong with such a protocol? Thanks in advance. Ágatha -- == Justin A. Lemkul, Ph.D. Assistant Professor Virginia Tech Department of Biochemistry 303 Engel Hall 340 West Campus Dr. Blacksburg, VA 24061 jalem...@vt.edu | (540) 231-3129 http://www.biochem.vt.edu/people/faculty/JustinLemkul.html == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Ionic liquid simulation problem
On 9/13/17 5:55 PM, Agatha Faria wrote: Dear GROMACS Community, I am very new with GROMACS I am trying to run a simulation of an ionic liquid (1-butyl-3-methyl-imidazolium and hexafluorophosphate) according to the following protocol: 1. Prepared the respective PDB files and added/modified the OPLS/AA force field parameters updating the atomtypes.atp, aminoacid.rtp, ffbonded.itp and ffnonbonded.itp files. 2. Used pdb2gmx command to create the respective .gro files, as well as, the posre.itp and topol.top files chossing OPLS/AA option without solvation. 3. Used the insert-molecules command to create a box filled with one specie (cation) and add the other specie (anion) into the same box. 4. Updated, by hand, the generated topol_box.top (pos_box.top) file including the topol.top and the posre.itp files of the other specie (anion) at the end of it. 5. Tried to used the grompp command to minimize the energy of the cations+anions box and got the following error: Fatal error: Too many warnings (18), gmx terminated. If you are sure all warnings are harmless, use the -maxwarn option. 6. Using a -maxwarn option got the following error: Error in user input: Invalid command-line options In command-line option -maxwarn Too few (valid) values Does anyone knows whats is wrong with such a protocol? The 18 warnings that were issued tell you what your problems are, but you haven't shared those. Do not use -maxwarn. A grompp warning indicates that something is badly wrong. "Notes" are advice, and "warnings" are signals of danger. Don't bypass the warnings. Fix them. -Justin -- == Justin A. Lemkul, Ph.D. Assistant Professor Virginia Tech Department of Biochemistry 303 Engel Hall 340 West Campus Dr. Blacksburg, VA 24061 jalem...@vt.edu | (540) 231-3129 http://www.biochem.vt.edu/people/faculty/JustinLemkul.html == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Ionic liquid simulation problem
Hi Ghosh, Thanks for your answer. But I'm not sure if I understood what you meant. I already used insert-molecules command to create a box with the cationic species. Now, should I use the same command to include the anionic species into the box? Best *Prof. Dr. Ednilsom OrestesDepartamento de Ciências Exatas - Sala C19Escola de Engenharia Industrial Metalúrgica de Volta Redonda* *Universidade Federal FluminenseR. dos Trabalhadores, 420 - Vila Santa Cecília* *Volta Redonda**, Rio de Janeiro, Brasil* *CEP 27255-125* *Tel: +55-24-2107-3777* 2017-09-05 17:24 GMT-03:00 soumadwip ghosh: > Hi, > > I am not sure why you used the gmx solvate command for putting the > anionic species in your simulation box. It is meant for filling up the > simulation box with water molceules as the resname 'SOL' in the > topol.top file. Thus when you hit grompp it expects 'SOL' entry in > your topology file, cant find it and prints an error. In my opinion, > one should use the same gmx insert-molecules command for inserting the > anionic part into the box. If you dont want to use water in the > simulation you can proceed without the solvation step but cant use gmx > solvate for inserting anionic species or anything else. > > Best > Soumadwip Ghosh > Post Doctoral Research Associate > City of Hope Cancer Research Center > Duarte 91010 CA > USA > -- > Gromacs Users mailing list > > * Please search the archive at http://www.gromacs.org/ > Support/Mailing_Lists/GMX-Users_List before posting! > > * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists > > * For (un)subscribe requests visit > https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or > send a mail to gmx-users-requ...@gromacs.org. > -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Ionic liquid simulation problem.
On 9/5/17 2:32 PM, Ednilsom Orestes wrote: Dear GROMACS Community, I am very new with GROMACS I am trying to run a simulation of an ionic liquid (1-butyl-3-methyl-imidazolium and hexafluorophosphate) according to the following protocol: 1. Prepared the respective PDB files and added/modified the OPLS/AA force field parameters updating the atomtypes.atp, aminoacid.rtp, ffbonded.itp and ffnonbonded.itp files. 2. Used *pdb2gmx* command to create the respective .gro files, as well as, the posre.itp and topol.top files chossing OPLS/AA option without solvation. 3. Used the *insert-molecules* command to create a box filled with one specie (cation) and used the *solva**te* command to add the other specie (anion) as solvent into the same box. 4. Updated, by hand, the generated topol_box.top (pos_box.top) file including the topol.top and the posre.itp files of the other specie (anion) at the end of it. 5. I them tried to used the *grompp* command to minimize the energy of the cations+anions box and got the following error: Fatal error: Syntax error – File forcefield.itp, line 20 Last line read: ‘1 3yes 0.5 0.5' Found a second defaut directive. Does anyone knows whats is wrong with such a protocol? This means you've got a syntactically invalid force field file, as you're trying to set two [defaults] directives (the actual instructions for the force field functional form, so there can only be one). -Justin -- == Justin A. Lemkul, Ph.D. Assistant Professor Virginia Tech Department of Biochemistry 303 Engel Hall 340 West Campus Dr. Blacksburg, VA 24061 jalem...@vt.edu | (540) 231-3129 http://www.biochem.vt.edu/people/faculty/JustinLemkul.html == -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.
Re: [gmx-users] Ionic liquid simulation problem
Hi, I am not sure why you used the gmx solvate command for putting the anionic species in your simulation box. It is meant for filling up the simulation box with water molceules as the resname 'SOL' in the topol.top file. Thus when you hit grompp it expects 'SOL' entry in your topology file, cant find it and prints an error. In my opinion, one should use the same gmx insert-molecules command for inserting the anionic part into the box. If you dont want to use water in the simulation you can proceed without the solvation step but cant use gmx solvate for inserting anionic species or anything else. Best Soumadwip Ghosh Post Doctoral Research Associate City of Hope Cancer Research Center Duarte 91010 CA USA -- Gromacs Users mailing list * Please search the archive at http://www.gromacs.org/Support/Mailing_Lists/GMX-Users_List before posting! * Can't post? Read http://www.gromacs.org/Support/Mailing_Lists * For (un)subscribe requests visit https://maillist.sys.kth.se/mailman/listinfo/gromacs.org_gmx-users or send a mail to gmx-users-requ...@gromacs.org.