Re: A JCL Problem question
On 26 May 2011 13:46:10 -0700, in bit.listserv.ibm-main (Message-ID:) sergio.co...@cetip.com.br (Sérgio Lima Costa) wrote: But, when try run, this mistake appear, and I can't see where is the problem : IEC130I SYSTSIN DD STATEMENT MISSING IEF472I BINDSYS DB2COB - COMPLETION CODE - SYSTEM=000 USER=0102 REASON= The SYSTSIN is there, where is the problem ? You have a SYSTSIN on the 2nd step, but the error message seems to be coming from the first step. -- I cannot receive mail at the address this was sent from. To reply directly, send to ar23hur "at" pobox "dot" com -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: A JCL Problem question
The error message is not referring to the BINDSYS step, but to the BINDSYS procstep of the DB2COB step executing the COMP006L procedure. regards, Gunnar - Original Message - From: "Sérgio Lima Costa" Newsgroups: bit.listserv.ibm-main To: Sent: Thursday, May 26, 2011 10:35 PM Subject: A JCL Problem question Hello List, I tried, write here, a REXX routine from compile COBOL batch with DB2. The JCL generated is this : // JOB (DES,SP,72664,09,30),&SYSUID,CLASS=N, // NOTIFY=&SYSUID,MSGLEVEL=(1,1),MSGCLASS=T //JOBLIB DD DISP=SHR,DSN=DB2.SDSNLOAD // DD DISP=SHR,DSN=CEE.SCEERUN //DB2COB EXEC COMP006L,MEM=PROG001, // DBRMLIB=PROD.DBRMLIB //* SRCLIB=PROD.DCLGEN //PC.SYSIN DD DSN=SERGIOL.FONTES.BATCH(PROG001),DISP=SHR //* //COBOL.SYSLIB DD DSN=PROD.COPYLIB,DISP=SHR //LKED.SYSLMOD DD DSN=SERGIOL.TSO.LOAD,DISP=SHR //LKED.SYSIN DD * NAME PROG001(R) /* //BINDSYS EXEC PGM=IKJEFT01,DYNAMNBR=20,COND=(4,LT) //DBRMLIB DD DISP=SHR,DSN=PROD.DBRMLIB //SYSTSPRT DD SYSOUT=* //SYSPRINT DD SYSOUT=* //SYSUDUMP DD SYSOUT=* //SYSTSIN DD * DSN SYSTEM(DB2P) BIND PLAN(PROG001) - MEMBER(PROG001) - LIBRARY ('PROD.DBRMLIB') - ACTION(REP) - ISOLATION (CS) - VALIDATE (BIND) - RELEASE (COMMIT) - ACQUIRE (USE) END But, when try run, this mistake appear, and I can't see where is the problem : IEC130I SYSTSIN DD STATEMENT MISSING IEF472I BINDSYS DB2COB - COMPLETION CODE - SYSTEM=000 USER=0102 REASON= The SYSTSIN is there, where is the problem ? Thanks, Sergio Lima -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
RES: A JCL Problem question
Hello List, Sorry about this trouble. This question is solved. My apologize. Sergio -Mensagem original- De: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] Em nome de Sérgio Lima Costa Enviada em: quinta-feira, 26 de maio de 2011 17:35 Para: IBM-MAIN@bama.ua.edu Assunto: A JCL Problem question Hello List, I tried, write here, a REXX routine from compile COBOL batch with DB2. The JCL generated is this : // JOB (DES,SP,72664,09,30),&SYSUID,CLASS=N, // NOTIFY=&SYSUID,MSGLEVEL=(1,1),MSGCLASS=T //JOBLIB DD DISP=SHR,DSN=DB2.SDSNLOAD // DD DISP=SHR,DSN=CEE.SCEERUN //DB2COB EXEC COMP006L,MEM=PROG001, // DBRMLIB=PROD.DBRMLIB //* SRCLIB=PROD.DCLGEN //PC.SYSIN DD DSN=SERGIOL.FONTES.BATCH(PROG001),DISP=SHR //* //COBOL.SYSLIB DD DSN=PROD.COPYLIB,DISP=SHR //LKED.SYSLMOD DD DSN=SERGIOL.TSO.LOAD,DISP=SHR //LKED.SYSIN DD * NAME PROG001(R) /* //BINDSYS EXEC PGM=IKJEFT01,DYNAMNBR=20,COND=(4,LT) //DBRMLIB DD DISP=SHR,DSN=PROD.DBRMLIB //SYSTSPRT DD SYSOUT=* //SYSPRINT DD SYSOUT=* //SYSUDUMP DD SYSOUT=* //SYSTSIN DD * DSN SYSTEM(DB2P) BIND PLAN(PROG001) - MEMBER(PROG001) - LIBRARY ('PROD.DBRMLIB') - ACTION(REP) - ISOLATION (CS) - VALIDATE (BIND) - RELEASE (COMMIT) - ACQUIRE (USE) END But, when try run, this mistake appear, and I can't see where is the problem : IEC130I SYSTSIN DD STATEMENT MISSING IEF472I BINDSYS DB2COB - COMPLETION CODE - SYSTEM=000 USER=0102 REASON= The SYSTSIN is there, where is the problem ? Thanks, Sergio Lima "Atenção: Esta mensagem foi enviada para uso exclusivo do(s) destinatários(s) acima identificado(s), podendo conter informações e/ou documentos confidencias/privilegiados e seu sigilo é protegido por lei. Caso você tenha recebido por engano, por favor, informe o remetente e apague-a de seu sistema. Notificamos que é proibido por lei a sua retenção, disseminação, distribuição, cópia ou uso sem expressa autorização do remetente. Opiniões pessoais do remetente não refletem, necessariamente, o ponto de vista da companhia, o qual é divulgado somente por pessoas autorizadas." "Warning: This message was sent for exclusive use of the addressees above identified, possibly containing information and or privileged/confidential documents whose content is protected by law. In case you have mistakenly received it, please notify the sender and delete it from your system. Be noticed that the law forbids the retention, dissemination, distribution, copy or use without express authorization from the sender. Personal opinions of the sender do not necessarily reflect the company's point of view, which is only divulged by authorized personnel." -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html "Atenção: Esta mensagem foi enviada para uso exclusivo do(s) destinatários(s) acima identificado(s), podendo conter informações e/ou documentos confidencias/privilegiados e seu sigilo é protegido por lei. Caso você tenha recebido por engano, por favor, informe o remetente e apague-a de seu sistema. Notificamos que é proibido por lei a sua retenção, disseminação, distribuição, cópia ou uso sem expressa autorização do remetente. Opiniões pessoais do remetente não refletem, necessariamente, o ponto de vista da companhia, o qual é divulgado somente por pessoas autorizadas." "Warning: This message was sent for exclusive use of the addressees above identified, possibly containing information and or privileged/confidential documents whose content is protected by law. In case you have mistakenly received it, please notify the sender and delete it from your system. Be noticed that the law forbids the retention, dissemination, distribution, copy or use without express authorization from the sender. Personal opinions of the sender do not necessarily reflect the company's point of view, which is only divulged by authorized personnel." -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
Re: A JCL Problem question
On Thu, 26 May 2011 17:35:26 -0300 Sérgio Lima Costa wrote: :>I tried, write here, a REXX routine from compile COBOL batch with DB2. :>The JCL generated is this : :>// JOB (DES,SP,72664,09,30),&SYSUID,CLASS=N, :>// NOTIFY=&SYSUID,MSGLEVEL=(1,1),MSGCLASS=T :>//JOBLIB DD DISP=SHR,DSN=DB2.SDSNLOAD :>// DD DISP=SHR,DSN=CEE.SCEERUN :>//DB2COB EXEC COMP006L,MEM=PROG001, :>// DBRMLIB=PROD.DBRMLIB :>//* SRCLIB=PROD.DCLGEN :>//PC.SYSIN DD DSN=SERGIOL.FONTES.BATCH(PROG001),DISP=SHR :>//* :>//COBOL.SYSLIB DD DSN=PROD.COPYLIB,DISP=SHR :>//LKED.SYSLMOD DD DSN=SERGIOL.TSO.LOAD,DISP=SHR :>//LKED.SYSIN DD * :> NAME PROG001(R) :>/* :>//BINDSYS EXEC PGM=IKJEFT01,DYNAMNBR=20,COND=(4,LT) :>//DBRMLIB DD DISP=SHR,DSN=PROD.DBRMLIB :>//SYSTSPRT DD SYSOUT=* :>//SYSPRINT DD SYSOUT=* :>//SYSUDUMP DD SYSOUT=* :>//SYSTSIN DD * :>DSN SYSTEM(DB2P) :> BIND PLAN(PROG001) - :> MEMBER(PROG001) - :> LIBRARY ('PROD.DBRMLIB') - :> ACTION(REP) - :> ISOLATION (CS) - :> VALIDATE (BIND) - :> RELEASE (COMMIT) - :> ACQUIRE (USE) :> END :>But, when try run, this mistake appear, and I can't see where is the problem : :>IEC130I SYSTSIN DD STATEMENT MISSING :>IEF472I BINDSYS DB2COB - COMPLETION CODE - SYSTEM=000 USER=0102 REASON= :>The SYSTSIN is there, where is the problem ? It would appear that there is a BINDSYS step in COMP006L proc. -- Binyamin Dissen http://www.dissensoftware.com Director, Dissen Software, Bar & Grill - Israel Should you use the mailblocks package and expect a response from me, you should preauthorize the dissensoftware.com domain. I very rarely bother responding to challenge/response systems, especially those from irresponsible companies. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html
A JCL Problem question
Hello List, I tried, write here, a REXX routine from compile COBOL batch with DB2. The JCL generated is this : // JOB (DES,SP,72664,09,30),&SYSUID,CLASS=N, // NOTIFY=&SYSUID,MSGLEVEL=(1,1),MSGCLASS=T //JOBLIB DD DISP=SHR,DSN=DB2.SDSNLOAD // DD DISP=SHR,DSN=CEE.SCEERUN //DB2COB EXEC COMP006L,MEM=PROG001, // DBRMLIB=PROD.DBRMLIB //* SRCLIB=PROD.DCLGEN //PC.SYSIN DD DSN=SERGIOL.FONTES.BATCH(PROG001),DISP=SHR //* //COBOL.SYSLIB DD DSN=PROD.COPYLIB,DISP=SHR //LKED.SYSLMOD DD DSN=SERGIOL.TSO.LOAD,DISP=SHR //LKED.SYSIN DD * NAME PROG001(R) /* //BINDSYS EXEC PGM=IKJEFT01,DYNAMNBR=20,COND=(4,LT) //DBRMLIB DD DISP=SHR,DSN=PROD.DBRMLIB //SYSTSPRT DD SYSOUT=* //SYSPRINT DD SYSOUT=* //SYSUDUMP DD SYSOUT=* //SYSTSIN DD * DSN SYSTEM(DB2P) BIND PLAN(PROG001) - MEMBER(PROG001) - LIBRARY ('PROD.DBRMLIB') - ACTION(REP) - ISOLATION (CS) - VALIDATE (BIND) - RELEASE (COMMIT) - ACQUIRE (USE) END But, when try run, this mistake appear, and I can't see where is the problem : IEC130I SYSTSIN DD STATEMENT MISSING IEF472I BINDSYS DB2COB - COMPLETION CODE - SYSTEM=000 USER=0102 REASON= The SYSTSIN is there, where is the problem ? Thanks, Sergio Lima "Atenção: Esta mensagem foi enviada para uso exclusivo do(s) destinatários(s) acima identificado(s), podendo conter informações e/ou documentos confidencias/privilegiados e seu sigilo é protegido por lei. Caso você tenha recebido por engano, por favor, informe o remetente e apague-a de seu sistema. Notificamos que é proibido por lei a sua retenção, disseminação, distribuição, cópia ou uso sem expressa autorização do remetente. Opiniões pessoais do remetente não refletem, necessariamente, o ponto de vista da companhia, o qual é divulgado somente por pessoas autorizadas." "Warning: This message was sent for exclusive use of the addressees above identified, possibly containing information and or privileged/confidential documents whose content is protected by law. In case you have mistakenly received it, please notify the sender and delete it from your system. Be noticed that the law forbids the retention, dissemination, distribution, copy or use without express authorization from the sender. Personal opinions of the sender do not necessarily reflect the company's point of view, which is only divulged by authorized personnel." -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html