Re: [EXTERNAL] Re: Profiles specific to user
Thanks all, so we've roughly come to the same answer, i.e., processing DBU00 using SORT/ICETOOL/REXX or Nigel's utilities.. Will wait to hear from Elardus on whether he can share his sweet pre-existing REXX 😊 – Vignesh Mainframe Infrastructure -Original Message- From: IBM Mainframe Discussion List On Behalf Of Walt Farrell Sent: 03 November 2018 22:07 To: IBM-MAIN@LISTSERV.UA.EDU Subject: [EXTERNAL] Re: Profiles specific to user On Sat, 3 Nov 2018 15:00:01 -0500, Mike Cairns wrote: >Unfortunately the SEARCH command only applies to the user executing the >command. Returning the profiles that *you*, the executing user, have access >to. I think what Vignesh is asking for is a list of the profiles for a given >user when asking the question as an administrator. I think you're forgetting the USER(userID) paramater on SEARCH, Mike: USER(userid) Specifies that RACF is to list the profiles that the specified user has access to (READ authority or higher, or owner) for the class you specify on the CLASS operand. RACF lists only those profiles that the specified owner is allowed to see. Nonetheless, I agree with you that using IRRDBU00 is a better approach, as SEARCH does not tell you -what- access the user has, nor -why- he has it. Generating a report based on IRRDBU00 output can tell you both of those, though you do need to perform the additional processing to include accesses based on the user's groups and UACC. -- Walt -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN MARKSANDSPENCER.COM Unless otherwise stated above: Marks and Spencer plc Registered Office: Waterside House 35 North Wharf Road London W2 1NW Registered No. 214436 in England and Wales. Telephone (020) 7935 4422 Facsimile (020) 7487 2670 www.marksandspencer.com Please note that electronic mail may be monitored. This e-mail is confidential. If you received it by mistake, please let us know and then delete it from your system; you should not copy, disclose, or distribute its contents to anyone nor act in reliance on this e-mail, as this is prohibited and may be unlawful. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
Re: Ziip pricing
There is a onetime charge and a monthly or yearly maintenance charge. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Peter Sent: Sunday, November 4, 2018 1:05 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Ziip pricing Hi Just want to check about how ziip pricing are done. Is it a one time charge we pay to IBM or else it is a yearly subscription ? Peter -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN הודעה זו נשלחה אליך מטעם חברה בקבוצת מלם תים וייתכן שהיא מוגנת תחת סודיות מסחרית. כל הצעה, התחייבות או מצג מטעם החברה, מחייבים מסמך נפרד וחתום על ידי מורשה החתימה של החברה. החברה רשאית לנטר כל תכתובת העוברת בשרתיה והיא לא תישא באחריות לכל נזק, ו/או אובדן, שיבוש או פגיעה במידע כלשהו שנגרם מסיבות של תקיפה חיצונית ו/או זדונית על הארגון. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
Ziip pricing
Hi Just want to check about how ziip pricing are done. Is it a one time charge we pay to IBM or else it is a yearly subscription ? Peter -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
Re: Enlarging SMS SCDS and ACDS
Thanks -Original Message- From: IBM Mainframe Discussion List On Behalf Of Allan Staller Sent: Sunday, November 4, 2018 12:03 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Enlarging SMS SCDS and ACDS There are several flavors of the SETSMS command to move the current CDS's from current to new. SETSMS SAVESCDS(new SCDS) SETSMS SAVEACDS(new ACDS) SETSMS COMMDS(new COMMDS) Define new (larger) datasets with IDCAMS and use the SETSMS Commads to populate and invoke the new datasets -Original Message- From: IBM Mainframe Discussion List On Behalf Of Gadi Ben-Avi Sent: Sunday, November 4, 2018 3:56 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Enlarging SMS SCDS and ACDS Hi, In the process of adding volumes to SMS Storage Groups, I ran out of space in the SCDS. What is the best way to enlarge the SCDS and ACDS? I am running z/OS v2.2 and I have DFSMSdss. Thanks Gadi ? ?? ? ?? ??? ??? ?? ? ??? ?? ??. ?? , ?? ??? ?, ??? ? ?? ??? ? ?? ?? ?. ? ? ?? ?? ?? ?? ?? ??? ??? ???, ?/?? ?, ? ?? ? ? ? ? ?? ?? ? ??? ?/?? ?? ?? ??. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN ::DISCLAIMER:: -- The contents of this e-mail and any attachment(s) are confidential and intended for the named recipient(s) only. E-mail transmission is not guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or may contain viruses in transmission. The e mail and its contents (with or without referred errors) shall therefore not attach any liability on the originator or HCL or its affiliates. Views or opinions, if any, presented in this email are solely those of the author and may not necessarily reflect the views or opinions of HCL or its affiliates. Any form of reproduction, dissemination, copying, disclosure, modification, distribution and / or publication of this message without the prior written consent of authorized representative of HCL is strictly prohibited. If you have received this email in error please delete it and notify the sender immediately. Before opening any email and/or attachments, please check them for viruses and other defects. -- -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN הודעה זו נשלחה אליך מטעם חברה בקבוצת מלם תים וייתכן שהיא מוגנת תחת סודיות מסחרית. כל הצעה, התחייבות או מצג מטעם החברה, מחייבים מסמך נפרד וחתום על ידי מורשה החתימה של החברה. החברה רשאית לנטר כל תכתובת העוברת בשרתיה והיא לא תישא באחריות לכל נזק, ו/או אובדן, שיבוש או פגיעה במידע כלשהו שנגרם מסיבות של תקיפה חיצונית ו/או זדונית על הארגון. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
Re: Enlarging SMS SCDS and ACDS
There are several flavors of the SETSMS command to move the current CDS's from current to new. SETSMS SAVESCDS(new SCDS) SETSMS SAVEACDS(new ACDS) SETSMS COMMDS(new COMMDS) Define new (larger) datasets with IDCAMS and use the SETSMS Commads to populate and invoke the new datasets -Original Message- From: IBM Mainframe Discussion List On Behalf Of Gadi Ben-Avi Sent: Sunday, November 4, 2018 3:56 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Enlarging SMS SCDS and ACDS Hi, In the process of adding volumes to SMS Storage Groups, I ran out of space in the SCDS. What is the best way to enlarge the SCDS and ACDS? I am running z/OS v2.2 and I have DFSMSdss. Thanks Gadi ? ?? ? ?? ??? ??? ?? ? ??? ?? ??. ?? , ?? ??? ?, ??? ? ?? ??? ? ?? ?? ?. ? ? ?? ?? ?? ?? ?? ??? ??? ???, ?/?? ?, ? ?? ? ? ? ? ?? ?? ? ??? ?/?? ?? ?? ??. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN ::DISCLAIMER:: -- The contents of this e-mail and any attachment(s) are confidential and intended for the named recipient(s) only. E-mail transmission is not guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or may contain viruses in transmission. The e mail and its contents (with or without referred errors) shall therefore not attach any liability on the originator or HCL or its affiliates. Views or opinions, if any, presented in this email are solely those of the author and may not necessarily reflect the views or opinions of HCL or its affiliates. Any form of reproduction, dissemination, copying, disclosure, modification, distribution and / or publication of this message without the prior written consent of authorized representative of HCL is strictly prohibited. If you have received this email in error please delete it and notify the sender immediately. Before opening any email and/or attachments, please check them for viruses and other defects. -- -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
Enlarging SMS SCDS and ACDS
Hi, In the process of adding volumes to SMS Storage Groups, I ran out of space in the SCDS. What is the best way to enlarge the SCDS and ACDS? I am running z/OS v2.2 and I have DFSMSdss. Thanks Gadi ? ?? ? ?? ??? ??? ?? ? ??? ?? ??. ?? , ?? ??? ?, ??? ? ?? ??? ? ?? ?? ?. ? ? ?? ?? ?? ?? ?? ??? ??? ???, ?/?? ?, ? ?? ? ? ? ? ?? ?? ? ??? ?/?? ?? ?? ??. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN