[jira] [Updated] (ARROW-2250) plasma_store process should cleanup on INT and TERM signals
[ https://issues.apache.org/jira/browse/ARROW-2250?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel ] ASF GitHub Bot updated ARROW-2250: -- Labels: pull-request-available (was: ) > plasma_store process should cleanup on INT and TERM signals > --- > > Key: ARROW-2250 > URL: https://issues.apache.org/jira/browse/ARROW-2250 > Project: Apache Arrow > Issue Type: Improvement >Affects Versions: 0.8.0 >Reporter: Mitar >Priority: Major > Labels: pull-request-available > > Currently, if you send an INT and TERM signal to a parent plasma store > process (Python one) it terminates it without cleaning the child process. > This makes it hard to run plasma store in non-interactive mode. Inside shell > ctrl-c kills both processes. > Moreover, INT prints out an ugly KeyboardInterrup exception. Probably > something nicer should be done. -- This message was sent by Atlassian JIRA (v7.6.3#76005)
[jira] [Updated] (ARROW-2250) plasma_store process should cleanup on INT and TERM signals as well
[ https://issues.apache.org/jira/browse/ARROW-2250?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel ] Mitar updated ARROW-2250: - Description: Currently, if you send an INT and TERM signal to a parent plasma store process (Python one) it terminates it without cleaning the child process. This makes it hard to run plasma store in non-interactive mode. Inside shell ctrl-c kills both processes. Moreover, INT prints out an ugly KeyboardInterrup exception. Probably something nicer should be done. was:Currently it cleans up on INT signal. But if it gets the TERM signal, then it kills the parent process (Python one) but not the binary process. I think both TERM and INT signals should be handled the same. Summary: plasma_store process should cleanup on INT and TERM signals as well (was: plasma_store process should cleanup on TERM signal as well) > plasma_store process should cleanup on INT and TERM signals as well > --- > > Key: ARROW-2250 > URL: https://issues.apache.org/jira/browse/ARROW-2250 > Project: Apache Arrow > Issue Type: Improvement >Affects Versions: 0.8.0 >Reporter: Mitar >Priority: Major > > Currently, if you send an INT and TERM signal to a parent plasma store > process (Python one) it terminates it without cleaning the child process. > This makes it hard to run plasma store in non-interactive mode. Inside shell > ctrl-c kills both processes. > Moreover, INT prints out an ugly KeyboardInterrup exception. Probably > something nicer should be done. -- This message was sent by Atlassian JIRA (v7.6.3#76005)
[jira] [Updated] (ARROW-2250) plasma_store process should cleanup on INT and TERM signals
[ https://issues.apache.org/jira/browse/ARROW-2250?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel ] Mitar updated ARROW-2250: - Summary: plasma_store process should cleanup on INT and TERM signals (was: plasma_store process should cleanup on INT and TERM signals as well) > plasma_store process should cleanup on INT and TERM signals > --- > > Key: ARROW-2250 > URL: https://issues.apache.org/jira/browse/ARROW-2250 > Project: Apache Arrow > Issue Type: Improvement >Affects Versions: 0.8.0 >Reporter: Mitar >Priority: Major > > Currently, if you send an INT and TERM signal to a parent plasma store > process (Python one) it terminates it without cleaning the child process. > This makes it hard to run plasma store in non-interactive mode. Inside shell > ctrl-c kills both processes. > Moreover, INT prints out an ugly KeyboardInterrup exception. Probably > something nicer should be done. -- This message was sent by Atlassian JIRA (v7.6.3#76005)