Pavel Vinokurov created IGNITE-11378:
----------------------------------------

             Summary: Critical system errors on cluster with enabled peristance
                 Key: IGNITE-11378
                 URL: https://issues.apache.org/jira/browse/IGNITE-11378
             Project: Ignite
          Issue Type: Bug
          Components: persistence
            Reporter: Pavel Vinokurov
         Attachments: CheckpointLockReproducer.java

The attached reproducer shows the following exception during streaming data to 
cache:
[2019-02-21 16:15:23,202][ERROR][tcp-disco-msg-worker-[100a6976 
0:0:0:0:0:0:0:1%lo:47500]-#19%3%][root] Critical system error detected. Will be 
handled accordingly to configured handler [hnd=StopNodeOrHaltFailureHandler 
[tryStop=false, timeout=0, super=AbstractFailureHandler 
[ignoredFailureTypes=UnmodifiableSet []]], failureCtx=FailureContext 
[type=SYSTEM_WORKER_BLOCKED, err=class o.a.i.IgniteException: GridWorker 
[name=data-streamer-stripe-5, igniteInstanceName=3, finished=false, 
heartbeatTs=1550754912905]]]
class org.apache.ignite.IgniteException: GridWorker 
[name=data-streamer-stripe-5, igniteInstanceName=3, finished=false, 
heartbeatTs=1550754912905]

If the blocked timeout is changed by  
cfg.setSystemWorkerBlockedTimeout(30_000), after streaming data and restarting 
several nodes the following critical error occurs:
[2019-02-21 16:24:07,164][ERROR][grid-timeout-worker-#214%client%][G] Blocked 
system-critical thread has been detected. This can lead to cluster-wide 
undefined behaviour [threadName=tcp-comm-worker, blockedFor=36s]
[2019-02-21 16:24:07,166][WARN ][grid-timeout-worker-#214%client%][G] Thread 
[name="tcp-comm-worker-#25%client%", id=482, state=TIMED_WAITING, blockCnt=0, 
waitCnt=729]

[2019-02-21 16:24:07,168][ERROR][grid-timeout-worker-#214%client%][root] 
Critical system error detected. Will be handled accordingly to configured 
handler [hnd=StopNodeOrHaltFailureHandler [tryStop=false, timeout=0, 
super=AbstractFailureHandler [ignoredFailureTypes=UnmodifiableSet []]], 
failureCtx=FailureContext [type=SYSTEM_WORKER_BLOCKED, err=class 
o.a.i.IgniteException: GridWorker [name=tcp-comm-worker, 
igniteInstanceName=client, finished=false, heartbeatTs=1550755410331]]]
class org.apache.ignite.IgniteException: GridWorker [name=tcp-comm-worker, 
igniteInstanceName=client, finished=false, heartbeatTs=1550755410331]





--
This message was sent by Atlassian JIRA
(v7.6.3#76005)

Reply via email to