[jira] [Resolved] (KYLIN-2677) There is no place to view the project configuration and can only be viewed on the edit project page.

2017-06-21 Thread Billy Liu (JIRA)

 [ 
https://issues.apache.org/jira/browse/KYLIN-2677?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Billy Liu resolved KYLIN-2677.
--
Resolution: Fixed

> There is no place to view the project configuration and can only be viewed on 
> the edit project page.
> 
>
> Key: KYLIN-2677
> URL: https://issues.apache.org/jira/browse/KYLIN-2677
> Project: Kylin
>  Issue Type: Bug
>  Components: Web 
>Affects Versions: v2.1.0
>Reporter: peng.jianhua
>Assignee: peng.jianhua
>Priority: Minor
>  Labels: patch
> Fix For: v2.1.0
>
> Attachments: 
> 0001-KYLIN-2677-There-is-no-place-to-view-the-project-con.patch, before.PNG, 
> modify.PNG
>
>
> There is no place to view the project configuration and can only be viewed on 
> the edit project page.
> Add a tab to make it easier for users to view the project configuration.



--
This message was sent by Atlassian JIRA
(v6.4.14#64029)


[jira] [Commented] (KYLIN-2677) There is no place to view the project configuration and can only be viewed on the edit project page.

2017-06-21 Thread Billy Liu (JIRA)

[ 
https://issues.apache.org/jira/browse/KYLIN-2677?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel=16057546#comment-16057546
 ] 

Billy Liu commented on KYLIN-2677:
--

Thanks [~peng.jianhua], good catch. LGTM. Patch merged. 
https://github.com/apache/kylin/commit/5749aed4e23c0deecf23bc3971ccadafd861d600

> There is no place to view the project configuration and can only be viewed on 
> the edit project page.
> 
>
> Key: KYLIN-2677
> URL: https://issues.apache.org/jira/browse/KYLIN-2677
> Project: Kylin
>  Issue Type: Bug
>  Components: Web 
>Affects Versions: v2.1.0
>Reporter: peng.jianhua
>Assignee: peng.jianhua
>Priority: Minor
>  Labels: patch
> Fix For: v2.1.0
>
> Attachments: 
> 0001-KYLIN-2677-There-is-no-place-to-view-the-project-con.patch, before.PNG, 
> modify.PNG
>
>
> There is no place to view the project configuration and can only be viewed on 
> the edit project page.
> Add a tab to make it easier for users to view the project configuration.



--
This message was sent by Atlassian JIRA
(v6.4.14#64029)


[jira] [Commented] (KYLIN-2678) found error in test case KylinConfigCLITest

2017-06-21 Thread Billy Liu (JIRA)

[ 
https://issues.apache.org/jira/browse/KYLIN-2678?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel=16057534#comment-16057534
 ] 

Billy Liu commented on KYLIN-2678:
--

Hi [~whenwin] could you fix this issue? Thanks. 

> found error in test case KylinConfigCLITest
> ---
>
> Key: KYLIN-2678
> URL: https://issues.apache.org/jira/browse/KYLIN-2678
> Project: Kylin
>  Issue Type: Bug
>  Components: Tools, Build and Test
>Affects Versions: v2.0.0
> Environment: win7-x64
>Reporter: wangxianbin
>Assignee: wangxianbin
>Priority: Minor
>
> two issues found in test case KylinConfigCLITest:
> # PrintStream should be closed explicitly for avoiding local temp file 
> cleanup fail
> # System.lineSeparator() should be used instead of hard code by '\n' for OS 
> compatibility



--
This message was sent by Atlassian JIRA
(v6.4.14#64029)


[jira] [Created] (KYLIN-2678) found error in test case KylinConfigCLITest

2017-06-21 Thread wangxianbin (JIRA)
wangxianbin created KYLIN-2678:
--

 Summary: found error in test case KylinConfigCLITest
 Key: KYLIN-2678
 URL: https://issues.apache.org/jira/browse/KYLIN-2678
 Project: Kylin
  Issue Type: Bug
  Components: Tools, Build and Test
Affects Versions: v2.0.0
 Environment: win7-x64
Reporter: wangxianbin
Assignee: wangxianbin
Priority: Minor


two issues found in test case KylinConfigCLITest:
# PrintStream should be closed explicitly for avoiding local temp file cleanup 
fail
# System.lineSeparator() should be used instead of hard code by '\n' for OS 
compatibility



--
This message was sent by Atlassian JIRA
(v6.4.14#64029)


[jira] [Created] (KYLIN-2677) There is no place to view the project configuration and can only be viewed on the edit project page.

2017-06-21 Thread peng.jianhua (JIRA)
peng.jianhua created KYLIN-2677:
---

 Summary: There is no place to view the project configuration and 
can only be viewed on the edit project page.
 Key: KYLIN-2677
 URL: https://issues.apache.org/jira/browse/KYLIN-2677
 Project: Kylin
  Issue Type: Bug
  Components: Web 
Affects Versions: v2.1.0
Reporter: peng.jianhua
Assignee: peng.jianhua
Priority: Minor
 Fix For: v2.1.0
 Attachments: before.PNG, modify.PNG

There is no place to view the project configuration and can only be viewed on 
the edit project page.
Add a tab to make it easier for users to view the project configuration.



--
This message was sent by Atlassian JIRA
(v6.4.14#64029)