[plasma-pa] [Bug 427978] Unknown, non-working device shown in applet's popup with "Device name not found" text
https://bugs.kde.org/show_bug.cgi?id=427978 Nate Graham changed: What|Removed |Added Version Fixed In||5.20.4 -- You are receiving this mail because: You are watching all bug changes.
[plasma-pa] [Bug 427978] Unknown, non-working device shown in applet's popup with "Device name not found" text
https://bugs.kde.org/show_bug.cgi?id=427978 Nicolas Fella changed: What|Removed |Added Latest Commit|https://invent.kde.org/plas |https://invent.kde.org/plas |ma/plasma-pa/commit/61f0698 |ma/plasma-pa/commit/56bf583 |478ab39b81a79ee1359d5319051 |79fe507950a08240547710db5b6 |74c018 |c7b8bf --- Comment #10 from Nicolas Fella --- Git commit 56bf58379fe507950a08240547710db5b6c7b8bf by Nicolas Fella. Committed on 24/11/2020 at 18:30. Pushed by nicolasfella into branch 'Plasma/5.20'. Remove count property from PulseObjectFilterModel PlasmaCore.SortFilterModel already has a count property that does what we need. For reasons that I don't fully understand this extra count property confused the view in such a way that extra "empty" sink items were visible in certain circumstances. (cherry picked from commit 61f0698478ab39b81a79ee1359d531905174c018) M +0-8src/qml/PulseObjectFilterModel.qml https://invent.kde.org/plasma/plasma-pa/commit/56bf58379fe507950a08240547710db5b6c7b8bf -- You are receiving this mail because: You are watching all bug changes.
[plasma-pa] [Bug 427978] Unknown, non-working device shown in applet's popup with "Device name not found" text
https://bugs.kde.org/show_bug.cgi?id=427978 Nicolas Fella changed: What|Removed |Added Latest Commit||https://invent.kde.org/plas ||ma/plasma-pa/commit/61f0698 ||478ab39b81a79ee1359d5319051 ||74c018 Resolution|--- |FIXED Status|ASSIGNED|RESOLVED --- Comment #9 from Nicolas Fella --- Git commit 61f0698478ab39b81a79ee1359d531905174c018 by Nicolas Fella. Committed on 24/11/2020 at 18:29. Pushed by nicolasfella into branch 'master'. Remove count property from PulseObjectFilterModel PlasmaCore.SortFilterModel already has a count property that does what we need. For reasons that I don't fully understand this extra count property confused the view in such a way that extra "empty" sink items were visible in certain circumstances. M +0-8src/qml/PulseObjectFilterModel.qml https://invent.kde.org/plasma/plasma-pa/commit/61f0698478ab39b81a79ee1359d531905174c018 -- You are receiving this mail because: You are watching all bug changes.
[plasma-pa] [Bug 427978] Unknown, non-working device shown in applet's popup with "Device name not found" text
https://bugs.kde.org/show_bug.cgi?id=427978 Bug Janitor Service changed: What|Removed |Added Status|REPORTED|ASSIGNED Ever confirmed|0 |1 --- Comment #8 from Bug Janitor Service --- A possibly relevant merge request was started @ https://invent.kde.org/plasma/plasma-pa/-/merge_requests/30 -- You are receiving this mail because: You are watching all bug changes.
[plasma-pa] [Bug 427978] Unknown, non-working device shown in applet's popup with "Device name not found" text
https://bugs.kde.org/show_bug.cgi?id=427978 --- Comment #7 from Riccardo Robecchi --- Created attachment 133352 --> https://bugs.kde.org/attachment.cgi?id=133352&action=edit pacmd info after disabling the output Here are the outputs of the command before and after disabling the output. Let me know if you need anything else. -- You are receiving this mail because: You are watching all bug changes.
[plasma-pa] [Bug 427978] Unknown, non-working device shown in applet's popup with "Device name not found" text
https://bugs.kde.org/show_bug.cgi?id=427978 --- Comment #6 from Riccardo Robecchi --- Created attachment 133351 --> https://bugs.kde.org/attachment.cgi?id=133351&action=edit pacmd info before disabling the output -- You are receiving this mail because: You are watching all bug changes.
[plasma-pa] [Bug 427978] Unknown, non-working device shown in applet's popup with "Device name not found" text
https://bugs.kde.org/show_bug.cgi?id=427978 Nicolas Fella changed: What|Removed |Added CC||nicolas.fe...@gmx.de --- Comment #5 from Nicolas Fella --- Can you attack `pacmd info` from before and after disabling the output? -- You are receiving this mail because: You are watching all bug changes.
[plasma-pa] [Bug 427978] Unknown, non-working device shown in applet's popup with "Device name not found" text
https://bugs.kde.org/show_bug.cgi?id=427978 --- Comment #4 from Patrick Silva --- Created attachment 132600 --> https://bugs.kde.org/attachment.cgi?id=132600&action=edit screenshot taken on neon unstable (In reply to Patrick Silva from comment #1) > Sometimes I see "Device name not found" in plasma-pa applet of neon unstable > too. > In my case I think it is related to remote pulseaudio server that I use to > stream audio, via local network, from my laptop to speakers connected to my > desktop computer. I can reproduce with these steps: 1. start Plasma session on server machine 2. start Plasma session on client machine 3. suspend server machine to RAM "Device name not found" appears in plasma-pa applet and I need to restart Plasma session on client machine to get the correct remote pulseaudio output in plasma-pa applet again. -- You are receiving this mail because: You are watching all bug changes.
[plasma-pa] [Bug 427978] Unknown, non-working device shown in applet's popup with "Device name not found" text
https://bugs.kde.org/show_bug.cgi?id=427978 Nate Graham changed: What|Removed |Added CC||n...@kde.org Keywords||regression --- Comment #3 from Nate Graham --- lol weird -- You are receiving this mail because: You are watching all bug changes.
[plasma-pa] [Bug 427978] Unknown, non-working device shown in applet's popup with "Device name not found" text
https://bugs.kde.org/show_bug.cgi?id=427978 --- Comment #2 from Riccardo Robecchi --- I just noticed that the bug seems to trigger if I disable an output. In my case, I have a USB DAC and the GPU's HDMI output; if I disable the latter, the unknown device shows up. It seems then like the device is not removed from the list of the applet and therefore appears like an unknown device. -- You are receiving this mail because: You are watching all bug changes.
[plasma-pa] [Bug 427978] Unknown, non-working device shown in applet's popup with "Device name not found" text
https://bugs.kde.org/show_bug.cgi?id=427978 Patrick Silva changed: What|Removed |Added CC||bugsefor...@gmx.com --- Comment #1 from Patrick Silva --- Sometimes I see "Device name not found" in plasma-pa applet of neon unstable too. In my case I think it is related to remote pulseaudio server that I use to stream audio, via local network, from my laptop to speakers connected to my desktop computer. -- You are receiving this mail because: You are watching all bug changes.