https://bugs.kde.org/show_bug.cgi?id=438839

            Bug ID: 438839
           Summary: Wayland - turning monitor off and back on causes
                    plasmashell to crash
           Product: plasmashell
           Version: 5.22.1
          Platform: Archlinux Packages
                OS: Linux
            Status: REPORTED
          Severity: crash
          Priority: NOR
         Component: generic-crash
          Assignee: plasma-b...@kde.org
          Reporter: sekritma...@protonmail.com
  Target Milestone: 1.0

Created attachment 139463
  --> https://bugs.kde.org/attachment.cgi?id=139463&action=edit
kstart5 plasmashell log

SUMMARY
Turning primary monitor off and on causes plasmashell to crash, opened windows
seemingly unaffected, requires a manual start of plasmashell to get it back.

MONITOR CONFIGURATION
primary monitor HP-24f on HDMI-A-1

STEPS TO REPRODUCE
1. Turn monitor off
2. Turn monitor on

OBSERVED RESULT
plasmashell disappears and has to be started manually

EXPECTED RESULT
plasmashell continues to function normally

SOFTWARE/OS VERSIONS
Linux/KDE Plasma: 
(available in About System)
KDE Plasma Version: 5.22.1
KDE Frameworks Version: 5.83.0
Qt Version: 5.15.2

-- 
You are receiving this mail because:
You are watching all bug changes.

Reply via email to