Public bug reported:

[Impact]
USB devices connected to Terminus USB hub stop working after S3.

[Fix]
The Terminus hub seems to have a rather slow reset command, so we need to wait 
for extra time before doing any further action.

[Test]
After applying the fix, USB devices connected to the HUB no longer stop 
functioning after S3.

[Regression Potential]
Low. Although the fix affects all devices connect to the HUB, it has no 
functional change other than imposes longer delay time.

** Affects: linux (Ubuntu)
     Importance: Undecided
         Status: New

-- 
You received this bug notification because you are a member of Kernel
Packages, which is subscribed to linux in Ubuntu.
https://bugs.launchpad.net/bugs/1806850

Title:
  Fix Terminus USB hub that may breaks connected USB devices after S3

Status in linux package in Ubuntu:
  New

Bug description:
  [Impact]
  USB devices connected to Terminus USB hub stop working after S3.

  [Fix]
  The Terminus hub seems to have a rather slow reset command, so we need to 
wait for extra time before doing any further action.

  [Test]
  After applying the fix, USB devices connected to the HUB no longer stop 
functioning after S3.

  [Regression Potential]
  Low. Although the fix affects all devices connect to the HUB, it has no 
functional change other than imposes longer delay time.

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1806850/+subscriptions

-- 
Mailing list: https://launchpad.net/~kernel-packages
Post to     : kernel-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~kernel-packages
More help   : https://help.launchpad.net/ListHelp

Reply via email to