Re: modifying degraded raid 1 then re-adding other members is bad

2006-08-09 Thread Jan Engelhardt
 Why we're updating it BACKWARD in the first place?

To avoid writing to spares when it isn't needed - some people want
their spare drives to go to sleep.

That sounds a little dangerous. What if it decrements below 0?


Jan Engelhardt
-- 
-
To unsubscribe from this list: send the line unsubscribe linux-raid in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html


Re: modifying degraded raid 1 then re-adding other members is bad

2006-08-09 Thread Helge Hafting

Michael Tokarev wrote:

Why we're updating it BACKWARD in the first place?
  

Don't know this one...

Also, why, when we adding something to the array, the event counter is
checked -- should it resync regardless?

If you remove a drive and then add it back with
no changes in the meantime, then you don't want
a resync to happen.  Some people reboot their machine
every day (too much noise, heat or electricity at night),
a daily resync is excessive.

An which drive would you consider
the master copy anyway, if the event counts match?

Helge Hafting

-
To unsubscribe from this list: send the line unsubscribe linux-raid in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html


Re: modifying degraded raid 1 then re-adding other members is bad

2006-08-09 Thread Neil Brown
On Wednesday August 9, [EMAIL PROTECTED] wrote:
  Why we're updating it BACKWARD in the first place?
 
 To avoid writing to spares when it isn't needed - some people want
 their spare drives to go to sleep.
 
 That sounds a little dangerous. What if it decrements below 0?

It cannot.
md  decrements the event count only on a dirty-clean transition, and
only if it had previously incremented the count on a clean-dirty
transition.  So it can never go below what it was when the array was
assembled.

NeilBrown
-
To unsubscribe from this list: send the line unsubscribe linux-raid in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html


Re: modifying degraded raid 1 then re-adding other members is bad

2006-08-08 Thread Neil Brown
On Tuesday August 8, [EMAIL PROTECTED] wrote:
 Assume I have a fully-functional raid 1 between two disks, one
 hot-pluggable and the other fixed.
 
 If I unplug the hot-pluggable disk and reboot, the array will come up
 degraded, as intended.
 
 If I then modify a lot of the data in the raid device (say it's my
 root fs and I'm running daily Fedora development updates :-), which
 modifies only the fixed disk, and then plug the hot-pluggable disk in
 and re-add its members, it appears that it comes up without resyncing
 and, well, major filesystem corruption ensues.
 
 Is this a known issue, or should I try to gather more info about it?

Looks a lot like
   http://bugzilla.kernel.org/show_bug.cgi?id=6965

Attached are two patches.  One against -mm and one against -linus.

They are below.

Please confirm if the appropriate one help.

NeilBrown

(-mm)

Avoid backward event updates in md superblock when degraded.

If we
  - shut down a clean array,
  - restart with one (or more) drive(s) missing
  - make some changes
  - pause, so that they array gets marked 'clean',
the event count on the superblock of included drives
will be the same as that of the removed drives.
So adding the removed drive back in will cause it
to be included with no resync.

To avoid this, we only update the eventcount backwards when the array
is not degraded.  In this case there can (should) be no non-connected
drives that we can get confused with, and this is the particular case
where updating-backwards is valuable.


Signed-off-by: Neil Brown [EMAIL PROTECTED]

### Diffstat output
 ./drivers/md/md.c |   11 +++
 1 file changed, 11 insertions(+)

diff .prev/drivers/md/md.c ./drivers/md/md.c
--- .prev/drivers/md/md.c   2006-08-03 11:42:48.0 +1000
+++ ./drivers/md/md.c   2006-08-07 08:57:10.0 +1000
@@ -1609,6 +1609,17 @@ repeat:
nospares = 1;
if (force_change)
nospares = 0;
+   if (mddev-degraded)
+   /* If the array is degraded, then skipping spares is both
+* dangerous and fairly pointless.
+* Dangerous because a device that was removed from the array
+* might have a event_count that still looks up-to-date,
+* so it can be re-added without a resync.
+* Pointless because if there are any spares to skip,
+* then a recovery will happen and soon that array won't
+* be degraded any more and the spare can go back to sleep then.
+*/
+   nospares = 0;
 
sync_req = mddev-in_sync;
mddev-utime = get_seconds();

---

(-linus)

Avoid backward event updates in md superblock when degraded.

If we
  - shut down a clean array,
  - restart with one (or more) drive(s) missing
  - make some changes
  - pause, so that they array gets marked 'clean',
the event count on the superblock of included drives
will be the same as that of the removed drives.
So adding the removed drive back in will cause it
to be included with no resync.

To avoid this, we only update the eventcount backwards when the array
is not degraded.  In this case there can (should) be no non-connected
drives that we can get confused with, and this is the particular case
where updating-backwards is valuable.


Signed-off-by: Neil Brown [EMAIL PROTECTED]

### Diffstat output
 ./drivers/md/md.c |   13 +
 1 file changed, 13 insertions(+)

diff .prev/drivers/md/md.c ./drivers/md/md.c
--- .prev/drivers/md/md.c   2006-08-08 09:00:44.0 +1000
+++ ./drivers/md/md.c   2006-08-08 09:04:04.0 +1000
@@ -1597,6 +1597,19 @@ void md_update_sb(mddev_t * mddev)
 
 repeat:
spin_lock_irq(mddev-write_lock);
+
+   if (mddev-degraded  mddev-sb_dirty == 3)
+   /* If the array is degraded, then skipping spares is both
+* dangerous and fairly pointless.
+* Dangerous because a device that was removed from the array
+* might have a event_count that still looks up-to-date,
+* so it can be re-added without a resync.
+* Pointless because if there are any spares to skip,
+* then a recovery will happen and soon that array won't
+* be degraded any more and the spare can go back to sleep then.
+*/
+   mddev-sb_dirty = 1;
+
sync_req = mddev-in_sync;
mddev-utime = get_seconds();
if (mddev-sb_dirty == 3)
-
To unsubscribe from this list: send the line unsubscribe linux-raid in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html


Re: modifying degraded raid 1 then re-adding other members is bad

2006-08-08 Thread Michael Tokarev
Neil Brown wrote:
 On Tuesday August 8, [EMAIL PROTECTED] wrote:
 Assume I have a fully-functional raid 1 between two disks, one
 hot-pluggable and the other fixed.

 If I unplug the hot-pluggable disk and reboot, the array will come up
 degraded, as intended.

 If I then modify a lot of the data in the raid device (say it's my
 root fs and I'm running daily Fedora development updates :-), which
 modifies only the fixed disk, and then plug the hot-pluggable disk in
 and re-add its members, it appears that it comes up without resyncing
 and, well, major filesystem corruption ensues.

 Is this a known issue, or should I try to gather more info about it?
 
 Looks a lot like
http://bugzilla.kernel.org/show_bug.cgi?id=6965
 
 Attached are two patches.  One against -mm and one against -linus.
 
 They are below.
 
 Please confirm if the appropriate one help.
 
 NeilBrown
 
 (-mm)
 
 Avoid backward event updates in md superblock when degraded.
 
 If we
   - shut down a clean array,
   - restart with one (or more) drive(s) missing
   - make some changes
   - pause, so that they array gets marked 'clean',
 the event count on the superblock of included drives
 will be the same as that of the removed drives.
 So adding the removed drive back in will cause it
 to be included with no resync.
 
 To avoid this, we only update the eventcount backwards when the array
 is not degraded.  In this case there can (should) be no non-connected
 drives that we can get confused with, and this is the particular case
 where updating-backwards is valuable.

Why we're updating it BACKWARD in the first place?

Also, why, when we adding something to the array, the event counter is
checked -- should it resync regardless?

Thanks.

/mjt
-
To unsubscribe from this list: send the line unsubscribe linux-raid in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html


Re: modifying degraded raid 1 then re-adding other members is bad

2006-08-08 Thread Krzysztof Halasa
Michael Tokarev [EMAIL PROTECTED] writes:

 Why we're updating it BACKWARD in the first place?

Another scenario: 1 disk (of 2) is removed, another is added, RAID-1
is rebuilt, then the disk added last is removed and replaced by
the disk which was removed first. Would it trigger this problem?

 Also, why, when we adding something to the array, the event counter is
 checked -- should it resync regardless?

I think it's a full start, not a hot add. For hot add contents of
the new disk should be ignored.
-- 
Krzysztof Halasa
-
To unsubscribe from this list: send the line unsubscribe linux-raid in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html


Re: modifying degraded raid 1 then re-adding other members is bad

2006-08-08 Thread Neil Brown
On Tuesday August 8, [EMAIL PROTECTED] wrote:
 
 Why we're updating it BACKWARD in the first place?
 

To avoid writing to spares when it isn't needed - some people want
their spare drives to go to sleep.

If we increment the event count without writing to the spares, the
spares quickly get left behind and won't be included next time the
array is assembled.
So on superblock updates that are purely for setting/clearing the
'dirty' bit, we rock back and forward between X and X+1, while leaving
the spares with 'X'.  A difference of 1 isn't enough to leave a drive
out of an array, so the spares stay part of the array.
The 'X is clean, the X+1 is dirty, so if there is any inconsistency
at startup, the 'dirty' will win, which is proper.

Any other superblock change like drives failing or being added cause a
normal forward change of 'events' and spares get written to as well.


 Also, why, when we adding something to the array, the event counter is
 checked -- should it resync regardless?

If we know it to be in sync, why should we resync it?

This is part of a longer term strategy to plan nicely with hotplug.

What I would like is that whenever hotplug finds a device, the hotplug
system can call
   mdadm --hot-plug-this-new-drive-somewhere-useful /dev/newdisk

(or something like that) and the drive will be added to an appropriate
array (if there is one).

So now you have the question: when do you actually activate an array?
Do I wait until there are just enough drives to start it degraded or
do I wait until all drives are present?
The later might never happen.  The former might cause lots of
unnecessary resync.

With the above feature (hot add of a current drive doesn't cause a
resync) then I can activate the array as soon as there are enough
drive for it to work at all.  It can then be read from even though it
isn't complete.
Once the first write happens we commit to the current layout and a new
drive will have to be resynced.  but if the array becomes complete
before the first write, no resync will be needed.

Hope that makes it a bit clearer.

NeilBrown
-
To unsubscribe from this list: send the line unsubscribe linux-raid in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html


Re: modifying degraded raid 1 then re-adding other members is bad

2006-08-08 Thread Neil Brown
On Tuesday August 8, [EMAIL PROTECTED] wrote:
 Michael Tokarev [EMAIL PROTECTED] writes:
 
  Why we're updating it BACKWARD in the first place?
 
 Another scenario: 1 disk (of 2) is removed, another is added, RAID-1
 is rebuilt, then the disk added last is removed and replaced by
 the disk which was removed first. Would it trigger this problem?
 

No.  The removing and the adding will all move the event count clearly
forward and the removed drive will have an old event count and so will
not be considered for easy inclusion.


  Also, why, when we adding something to the array, the event counter is
  checked -- should it resync regardless?
 
 I think it's a full start, not a hot add. For hot add contents of
 the new disk should be ignored.

See my other post for why I want to sometimes not do a recovery on a
hot-add.

NeilBrown
-
To unsubscribe from this list: send the line unsubscribe linux-raid in
the body of a message to [EMAIL PROTECTED]