I would suggest opening a TAC to get the full details on why it’s happening if the root cause not readily apparent. Typically remediating a these types of mismatches entails copying the default config to startup (triggers a reload) and rejoining the fabric. On 6/30/16, 1:41 PM, "NANOG on behalf of Mike Hammett" <nanog-boun...@nanog.org on behalf of na...@ics-il.net> wrote:
>I asked on the Brocade forum, but it's largely been crickets there. I hoped >someone here would have an idea. > >One switch says: 23 Te 12/0/24 Up ISL segmented,(ESC mismatch, Distributed >Config DB)(Trunk Primary) >The other switch says: 23 Te 54/0/24 Up ISL segmented,(ESC mismatch, >Distributed Config DB)(Trunk Primary) > >I saw that means, "The DCM Configuration DB is different on both the ends of >ISL," but I have no idea how to resolve that. > > >VDX-6720s running 4.1.3b. > > > > >----- >Mike Hammett >Intelligent Computing Solutions >http://www.ics-il.com > > > >Midwest Internet Exchange >http://www.midwest-ix.com > >