I would suggest opening a TAC to get the full details on why it’s happening if 
the root cause not readily apparent. Typically remediating a these types of 
mismatches entails copying the default config to startup (triggers a reload) 
and rejoining the fabric.
        
On 6/30/16, 1:41 PM, "NANOG on behalf of Mike Hammett" <nanog-boun...@nanog.org 
on behalf of na...@ics-il.net> wrote:

>I asked on the Brocade forum, but it's largely been crickets there. I hoped 
>someone here would have an idea. 
>
>One switch says: 23 Te 12/0/24 Up ISL segmented,(ESC mismatch, Distributed 
>Config DB)(Trunk Primary) 
>The other switch says: 23 Te 54/0/24 Up ISL segmented,(ESC mismatch, 
>Distributed Config DB)(Trunk Primary) 
>
>I saw that means, "The DCM Configuration DB is different on both the ends of 
>ISL," but I have no idea how to resolve that. 
>
>
>VDX-6720s running 4.1.3b. 
>
>
>
>
>----- 
>Mike Hammett 
>Intelligent Computing Solutions 
>http://www.ics-il.com 
>
>
>
>Midwest Internet Exchange 
>http://www.midwest-ix.com 
>
>

Reply via email to