Hi Mandeep, Currently, we edit these templates manually without using any design tools. Best Regards, Yan 发件人: onap-discuss@lists.onap.org [mailto:onap-discuss@lists.onap.org] 代表 Mandeep Singh Kalra 发送时间: 2018年7月4日 12:21 收件人: Yan Yang; 'Addepalli, Srinivasa R'; denglin...@chinamobile.com 抄送: 'Rebecca Lantz'; 'Huang, Haibin'; onap-discuss@lists.onap.org 主题: Re: [External] 答复: [onap-discuss] VNF configuration via VFC Thanks a lot Yan. I guess these csars ( for eg vgw) are imported on the SDC. Do we use any tooling to create these tosca templates. For eg :: SDC also has a design studio to create the templates or vnfsdk is used here ? Regards Mandeep From: Yan Yang [mailto:yangya...@chinamobile.com] Sent: Wednesday, July 4, 2018 8:05 AM To: Singh Kalra, Mandeep ; 'Addepalli, Srinivasa R' ; denglin...@chinamobile.com Cc: 'Rebecca Lantz' ; 'Huang, Haibin' ; onap-discuss@lists.onap.org Subject: 答复: [External] 答复: [onap-discuss] VNF configuration via VFC Hi Mandeep, You can download the csar sample from <https://urldefense.proofpoint.com/v2/url?u=https-3A__github.com_hhb584520_vcpe-5Ftosca_blob_master_vgw.csar=DwMFaQ=eIGjsITfXP_y-DLLX0uEHXJvU8nOHrUK8IrwNKOtkVU=p89qecmhInOVphGqjXrHzDWNu-0tx0ccbkDut9Mw215vuDwwoR96vo2NJnOHwduC=qz4gCuqFfceXw4jIOg-vfNWhRcuGGZotA0PxwUXKXiY=IHgmvq8HkZazHi2dKlNAEIDs0t-2eHbGcczD44rGqcI=> https://github.com/hhb584520/vcpe_tosca/blob/master/vgw.csar In this csar template ,there is a part called user_data, this may be the instantiation/configuration. Best Regards, Yan 发件人: Singh Kalra, Mandeep [mailto:mandeep.singh.ka...@accenture.com] 发送时间: 2018年7月2日 14:08 收件人: Yan Yang; 'Addepalli, Srinivasa R'; denglin...@chinamobile.com 抄送: 'Rebecca Lantz'; 'Huang, Haibin'; onap-discuss@lists.onap.org 主题: RE: [External] 答复: [onap-discuss] VNF configuration via VFC Thanks Yan. For VoLTE VNFs, we used SVNFMs to deploy them and deployed CPE VNFs via GVNFM. >> Is it possible to share the tosca model of the vCPE that will be created via >> gvnfm ? Does this model contains some scripts for vnf instantiation/configuration ? Regards Mandeep From: Yan Yang [mailto:yangya...@chinamobile.com] Sent: Tuesday, June 19, 2018 8:19 AM To: 'Addepalli, Srinivasa R' ; denglin...@chinamobile.com Cc: 'Rebecca Lantz' ; Singh Kalra, Mandeep ; 'Huang, Haibin' ; onap-discuss@lists.onap.org Subject: [External] 答复: [onap-discuss] VNF configuration via VFC Hi Srini, In R2, we used direct mode to test VoLTE use case. For VoLTE VNFs, we used SVNFMs to deploy them and deployed CPE VNFs via GVNFM. Best Regards, Yan 发件人: Addepalli, Srinivasa R [mailto:srinivasa.r.addepa...@intel.com] 发送时间: 2018年6月18日 2:24 收件人: denglin...@chinamobile.com 抄送: yangya...@chinamobile.com; 'Rebecca Lantz'; 'Singh Kalra, Mandeep'; Huang, Haibin; onap-discuss@lists.onap.org 主题: RE: [onap-discuss] VNF configuration via VFC Hi Lingli, Which model is tested in VOLTE use case? Do sVNFMs,used today in VOLTE, support indirect mode? You mentioned that VOLTE VMs can be placed either using GVNFM or sVNFMs. Are both tested in R2? Thanks Srini From: 邓灵莉 [mailto:denglin...@chinamobile.com] Sent: Sunday, June 17, 2018 8:29 AM To: Addepalli, Srinivasa R Cc: yangya...@chinamobile.com; 'Rebecca Lantz' ; 'Singh Kalra, Mandeep' ; Huang, Haibin ; onap-discuss@lists.onap.org Subject: Re: [onap-discuss] VNF configuration via VFC There are two models for NFVO, VNFM and VIM interfacing. One is direct model, where VNFM calls VIM directly. The other is indirect model, where NFVO acting as the proxy between the two and calls VIM for the VNFM. In either case, the VNFM could be a third party SVNFM or the GVNFM as part of VFC. Lingli 发自网易邮箱大师 On 06/17/2018 23:14, <mailto:srinivasa.r.addepa...@intel.com> Addepalli, Srinivasa R wrote: Hi Yan, One related question. Once VF-C is called by POLICY for closed loop control actions such as “Heal”, “restart” and “scale-out”, does VF-C call vendors’ VNFMs to take these actions or does VF-C call Multi-Cloud service to take care of these actions? I heard two different answers before and hence the question. Also, it is good to know whether Multi-Cloud service is called any time by VoLTE use case( as all VNFs have corresponding VNFMs)? Thanks Srini From: yangya...@chinamobile.com [mailto:yangya...@chinamobile.com] Sent: Saturday, June 16, 2018 7:41 PM To: 'Rebecca Lantz' ; 'Singh Kalra, Mandeep' ; Huang, Haibin ; Addepalli, Srinivasa R ; onap-discuss@lists.onap.org Subject: 答复: [onap-discuss] VNF configuration via VFC Hi Rebecca, Taking the VoLTE use case as an example, VNF configuration is completed through the vendor EMS. VF-C provides an component called EMS driver which can translate alarms and performance received from the vendor EMS into VES format and report to DCAE VESCollector. Then the alarm
Re: [External] 答复: [onap-discuss] VNF configuration via VFC
Thanks a lot Yan. I guess these csars ( for eg vgw) are imported on the SDC. Do we use any tooling to create these tosca templates. For eg :: SDC also has a design studio to create the templates or vnfsdk is used here ? Regards Mandeep From: Yan Yang [mailto:yangya...@chinamobile.com] Sent: Wednesday, July 4, 2018 8:05 AM To: Singh Kalra, Mandeep ; 'Addepalli, Srinivasa R' ; denglin...@chinamobile.com Cc: 'Rebecca Lantz' ; 'Huang, Haibin' ; onap-discuss@lists.onap.org Subject: 答复: [External] 答复: [onap-discuss] VNF configuration via VFC Hi Mandeep, You can download the csar sample from https://github.com/hhb584520/vcpe_tosca/blob/master/vgw.csar<https://urldefense.proofpoint.com/v2/url?u=https-3A__github.com_hhb584520_vcpe-5Ftosca_blob_master_vgw.csar=DwMFaQ=eIGjsITfXP_y-DLLX0uEHXJvU8nOHrUK8IrwNKOtkVU=p89qecmhInOVphGqjXrHzDWNu-0tx0ccbkDut9Mw215vuDwwoR96vo2NJnOHwduC=qz4gCuqFfceXw4jIOg-vfNWhRcuGGZotA0PxwUXKXiY=IHgmvq8HkZazHi2dKlNAEIDs0t-2eHbGcczD44rGqcI=> In this csar template ,there is a part called user_data, this may be the instantiation/configuration. Best Regards, Yan 发件人: Singh Kalra, Mandeep [mailto:mandeep.singh.ka...@accenture.com] 发送时间: 2018年7月2日 14:08 收件人: Yan Yang; 'Addepalli, Srinivasa R'; denglin...@chinamobile.com<mailto:denglin...@chinamobile.com> 抄送: 'Rebecca Lantz'; 'Huang, Haibin'; onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org> 主题: RE: [External] 答复: [onap-discuss] VNF configuration via VFC Thanks Yan. For VoLTE VNFs, we used SVNFMs to deploy them and deployed CPE VNFs via GVNFM. >> Is it possible to share the tosca model of the vCPE that will be created via >> gvnfm ? Does this model contains some scripts for vnf instantiation/configuration ? Regards Mandeep From: Yan Yang [mailto:yangya...@chinamobile.com] Sent: Tuesday, June 19, 2018 8:19 AM To: 'Addepalli, Srinivasa R' mailto:srinivasa.r.addepa...@intel.com>>; denglin...@chinamobile.com<mailto:denglin...@chinamobile.com> Cc: 'Rebecca Lantz' mailto:rebecca.la...@ericsson.com>>; Singh Kalra, Mandeep mailto:mandeep.singh.ka...@accenture.com>>; 'Huang, Haibin' mailto:haibin.hu...@intel.com>>; onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org> Subject: [External] 答复: [onap-discuss] VNF configuration via VFC Hi Srini, In R2, we used direct mode to test VoLTE use case. For VoLTE VNFs, we used SVNFMs to deploy them and deployed CPE VNFs via GVNFM. Best Regards, Yan 发件人: Addepalli, Srinivasa R [mailto:srinivasa.r.addepa...@intel.com] 发送时间: 2018年6月18日 2:24 收件人: denglin...@chinamobile.com<mailto:denglin...@chinamobile.com> 抄送: yangya...@chinamobile.com<mailto:yangya...@chinamobile.com>; 'Rebecca Lantz'; 'Singh Kalra, Mandeep'; Huang, Haibin; onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org> 主题: RE: [onap-discuss] VNF configuration via VFC Hi Lingli, Which model is tested in VOLTE use case? Do sVNFMs,used today in VOLTE, support indirect mode? You mentioned that VOLTE VMs can be placed either using GVNFM or sVNFMs. Are both tested in R2? Thanks Srini From: 邓灵莉 [mailto:denglin...@chinamobile.com] Sent: Sunday, June 17, 2018 8:29 AM To: Addepalli, Srinivasa R mailto:srinivasa.r.addepa...@intel.com>> Cc: yangya...@chinamobile.com<mailto:yangya...@chinamobile.com>; 'Rebecca Lantz' mailto:rebecca.la...@ericsson.com>>; 'Singh Kalra, Mandeep' mailto:mandeep.singh.ka...@accenture.com>>; Huang, Haibin mailto:haibin.hu...@intel.com>>; onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org> Subject: Re: [onap-discuss] VNF configuration via VFC There are two models for NFVO, VNFM and VIM interfacing. One is direct model, where VNFM calls VIM directly. The other is indirect model, where NFVO acting as the proxy between the two and calls VIM for the VNFM. In either case, the VNFM could be a third party SVNFM or the GVNFM as part of VFC. Lingli 发自网易邮箱大师 On 06/17/2018 23:14, Addepalli, Srinivasa R<mailto:srinivasa.r.addepa...@intel.com> wrote: Hi Yan, One related question. Once VF-C is called by POLICY for closed loop control actions such as “Heal”, “restart” and “scale-out”, does VF-C call vendors’ VNFMs to take these actions or does VF-C call Multi-Cloud service to take care of these actions? I heard two different answers before and hence the question. Also, it is good to know whether Multi-Cloud service is called any time by VoLTE use case( as all VNFs have corresponding VNFMs)? Thanks Srini From: yangya...@chinamobile.com<mailto:yangya...@chinamobile.com> [mailto:yangya...@chinamobile.com] Sent: Saturday, June 16, 2018 7:41 PM To: 'Rebecca Lantz' mailto:rebecca.la...@ericsson.com>>; 'Singh Kalra, Mandeep' mailto:mandeep.singh.ka...@accenture.com>>; Huang, Haibin mailto:haibin.hu...@intel.com>>; Addepalli, Srinivasa R mailto:srinivasa.r.addepa...@intel.com>>; o
答复: [External] 答复: [onap-discuss] VNF configuration via VFC
Hi Mandeep, You can download the csar sample from <https://github.com/hhb584520/vcpe_tosca/blob/master/vgw.csar> https://github.com/hhb584520/vcpe_tosca/blob/master/vgw.csar In this csar template ,there is a part called user_data, this may be the instantiation/configuration. Best Regards, Yan 发件人: Singh Kalra, Mandeep [mailto:mandeep.singh.ka...@accenture.com] 发送时间: 2018年7月2日 14:08 收件人: Yan Yang; 'Addepalli, Srinivasa R'; denglin...@chinamobile.com 抄送: 'Rebecca Lantz'; 'Huang, Haibin'; onap-discuss@lists.onap.org 主题: RE: [External] 答复: [onap-discuss] VNF configuration via VFC Thanks Yan. For VoLTE VNFs, we used SVNFMs to deploy them and deployed CPE VNFs via GVNFM. >> Is it possible to share the tosca model of the vCPE that will be created via >> gvnfm ? Does this model contains some scripts for vnf instantiation/configuration ? Regards Mandeep From: Yan Yang [mailto:yangya...@chinamobile.com] Sent: Tuesday, June 19, 2018 8:19 AM To: 'Addepalli, Srinivasa R' ; denglin...@chinamobile.com Cc: 'Rebecca Lantz' ; Singh Kalra, Mandeep ; 'Huang, Haibin' ; onap-discuss@lists.onap.org Subject: [External] 答复: [onap-discuss] VNF configuration via VFC Hi Srini, In R2, we used direct mode to test VoLTE use case. For VoLTE VNFs, we used SVNFMs to deploy them and deployed CPE VNFs via GVNFM. Best Regards, Yan 发件人: Addepalli, Srinivasa R [mailto:srinivasa.r.addepa...@intel.com] 发送时间: 2018年6月18日 2:24 收件人: denglin...@chinamobile.com 抄送: yangya...@chinamobile.com; 'Rebecca Lantz'; 'Singh Kalra, Mandeep'; Huang, Haibin; onap-discuss@lists.onap.org 主题: RE: [onap-discuss] VNF configuration via VFC Hi Lingli, Which model is tested in VOLTE use case? Do sVNFMs,used today in VOLTE, support indirect mode? You mentioned that VOLTE VMs can be placed either using GVNFM or sVNFMs. Are both tested in R2? Thanks Srini From: 邓灵莉 [mailto:denglin...@chinamobile.com] Sent: Sunday, June 17, 2018 8:29 AM To: Addepalli, Srinivasa R Cc: yangya...@chinamobile.com; 'Rebecca Lantz' ; 'Singh Kalra, Mandeep' ; Huang, Haibin ; onap-discuss@lists.onap.org Subject: Re: [onap-discuss] VNF configuration via VFC There are two models for NFVO, VNFM and VIM interfacing. One is direct model, where VNFM calls VIM directly. The other is indirect model, where NFVO acting as the proxy between the two and calls VIM for the VNFM. In either case, the VNFM could be a third party SVNFM or the GVNFM as part of VFC. Lingli 发自网易邮箱大师 On 06/17/2018 23:14, <mailto:srinivasa.r.addepa...@intel.com> Addepalli, Srinivasa R wrote: Hi Yan, One related question. Once VF-C is called by POLICY for closed loop control actions such as “Heal”, “restart” and “scale-out”, does VF-C call vendors’ VNFMs to take these actions or does VF-C call Multi-Cloud service to take care of these actions? I heard two different answers before and hence the question. Also, it is good to know whether Multi-Cloud service is called any time by VoLTE use case( as all VNFs have corresponding VNFMs)? Thanks Srini From: yangya...@chinamobile.com [mailto:yangya...@chinamobile.com] Sent: Saturday, June 16, 2018 7:41 PM To: 'Rebecca Lantz' ; 'Singh Kalra, Mandeep' ; Huang, Haibin ; Addepalli, Srinivasa R ; onap-discuss@lists.onap.org Subject: 答复: [onap-discuss] VNF configuration via VFC Hi Rebecca, Taking the VoLTE use case as an example, VNF configuration is completed through the vendor EMS. VF-C provides an component called EMS driver which can translate alarms and performance received from the vendor EMS into VES format and report to DCAE VESCollector. Then the alarm is received by the DCAE application, such as Holmes(do alarm correlation ), then policy project will match the corresponding policy, and then call action actor, such as VF-C to do heal. Currently , VF-C does not support VNF configuration changes based on alarm close loop. Best Regards, Yan 发件人: onap-discuss-boun...@lists.onap.org [mailto:onap-discuss-boun...@lists.onap.org] 代表 Rebecca Lantz 发送时间: 2018年6月14日 21:51 收件人: Singh Kalra, Mandeep; Huang, Haibin; Addepalli, Srinivasa R; onap-discuss@lists.onap.org 主题: Re: [onap-discuss] VNF configuration via VFC Hi, I have a related question. Assume I am using VFC with a S-VNFM for LCM. And sure, I can use an external EM for configuration of my VNF. (This is the answer specified below) However, how can I utilize ONAP for closed loops using my VNF specific alarms and VNF specific configuration? If there is something in my VNF specific data model generating an alarm or counter (VES event) which I then want a policy to have a configuration change sent to the VNF. I believe this kind of closed loop could be done with APPC. If I am using VFC do I also use APPC somehow for this scenario? Thanks, Rebecca From: onap-discuss-boun...@lists.onap.org On Behalf
Re: [External] 答复: [onap-discuss] VNF configuration via VFC
Thanks Yan. For VoLTE VNFs, we used SVNFMs to deploy them and deployed CPE VNFs via GVNFM. >> Is it possible to share the tosca model of the vCPE that will be created via >> gvnfm ? Does this model contains some scripts for vnf instantiation/configuration ? Regards Mandeep From: Yan Yang [mailto:yangya...@chinamobile.com] Sent: Tuesday, June 19, 2018 8:19 AM To: 'Addepalli, Srinivasa R' ; denglin...@chinamobile.com Cc: 'Rebecca Lantz' ; Singh Kalra, Mandeep ; 'Huang, Haibin' ; onap-discuss@lists.onap.org Subject: [External] 答复: [onap-discuss] VNF configuration via VFC Hi Srini, In R2, we used direct mode to test VoLTE use case. For VoLTE VNFs, we used SVNFMs to deploy them and deployed CPE VNFs via GVNFM. Best Regards, Yan 发件人: Addepalli, Srinivasa R [mailto:srinivasa.r.addepa...@intel.com] 发送时间: 2018年6月18日 2:24 收件人: denglin...@chinamobile.com<mailto:denglin...@chinamobile.com> 抄送: yangya...@chinamobile.com<mailto:yangya...@chinamobile.com>; 'Rebecca Lantz'; 'Singh Kalra, Mandeep'; Huang, Haibin; onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org> 主题: RE: [onap-discuss] VNF configuration via VFC Hi Lingli, Which model is tested in VOLTE use case? Do sVNFMs,used today in VOLTE, support indirect mode? You mentioned that VOLTE VMs can be placed either using GVNFM or sVNFMs. Are both tested in R2? Thanks Srini From: 邓灵莉 [mailto:denglin...@chinamobile.com] Sent: Sunday, June 17, 2018 8:29 AM To: Addepalli, Srinivasa R mailto:srinivasa.r.addepa...@intel.com>> Cc: yangya...@chinamobile.com<mailto:yangya...@chinamobile.com>; 'Rebecca Lantz' mailto:rebecca.la...@ericsson.com>>; 'Singh Kalra, Mandeep' mailto:mandeep.singh.ka...@accenture.com>>; Huang, Haibin mailto:haibin.hu...@intel.com>>; onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org> Subject: Re: [onap-discuss] VNF configuration via VFC There are two models for NFVO, VNFM and VIM interfacing. One is direct model, where VNFM calls VIM directly. The other is indirect model, where NFVO acting as the proxy between the two and calls VIM for the VNFM. In either case, the VNFM could be a third party SVNFM or the GVNFM as part of VFC. Lingli 发自网易邮箱大师 On 06/17/2018 23:14, Addepalli, Srinivasa R<mailto:srinivasa.r.addepa...@intel.com> wrote: Hi Yan, One related question. Once VF-C is called by POLICY for closed loop control actions such as “Heal”, “restart” and “scale-out”, does VF-C call vendors’ VNFMs to take these actions or does VF-C call Multi-Cloud service to take care of these actions? I heard two different answers before and hence the question. Also, it is good to know whether Multi-Cloud service is called any time by VoLTE use case( as all VNFs have corresponding VNFMs)? Thanks Srini From: yangya...@chinamobile.com<mailto:yangya...@chinamobile.com> [mailto:yangya...@chinamobile.com] Sent: Saturday, June 16, 2018 7:41 PM To: 'Rebecca Lantz' mailto:rebecca.la...@ericsson.com>>; 'Singh Kalra, Mandeep' mailto:mandeep.singh.ka...@accenture.com>>; Huang, Haibin mailto:haibin.hu...@intel.com>>; Addepalli, Srinivasa R mailto:srinivasa.r.addepa...@intel.com>>; onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org> Subject: 答复: [onap-discuss] VNF configuration via VFC Hi Rebecca, Taking the VoLTE use case as an example, VNF configuration is completed through the vendor EMS. VF-C provides an component called EMS driver which can translate alarms and performance received from the vendor EMS into VES format and report to DCAE VESCollector. Then the alarm is received by the DCAE application, such as Holmes(do alarm correlation ), then policy project will match the corresponding policy, and then call action actor, such as VF-C to do heal. Currently , VF-C does not support VNF configuration changes based on alarm close loop. Best Regards, Yan 发件人: onap-discuss-boun...@lists.onap.org<mailto:onap-discuss-boun...@lists.onap.org> [mailto:onap-discuss-boun...@lists.onap.org] 代表 Rebecca Lantz 发送时间: 2018年6月14日 21:51 收件人: Singh Kalra, Mandeep; Huang, Haibin; Addepalli, Srinivasa R; onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org> 主题: Re: [onap-discuss] VNF configuration via VFC Hi, I have a related question. Assume I am using VFC with a S-VNFM for LCM. And sure, I can use an external EM for configuration of my VNF. (This is the answer specified below) However, how can I utilize ONAP for closed loops using my VNF specific alarms and VNF specific configuration? If there is something in my VNF specific data model generating an alarm or counter (VES event) which I then want a policy to have a configuration change sent to the VNF. I believe this kind of closed loop could be done with APPC. If I am using VFC do I also use APPC somehow for this scenario? Thanks, Rebecca From: onap-discuss-boun...@lists.onap.org<mailto