Am făcut o fereastră de mentenanță și am luat următoarele acțiuni: 1. Reboot server cu HDD scos - îl vedea ca failed 0M: => controller slot=0 show config
Smart Array P410i in Slot 0 (Embedded) (sn: 500143800891C3B0) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (136.7 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 2 (1.4 TB, RAID 5, Interim Recovery Mode) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, Predictive Failure) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 0 MB, Failed) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK) physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, OK) physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143800891C3BF) => 2. Inserat disc - nu vedea nimic la rescan așa că am mai dat un restart de server, iar acum: => controller slot=0 show config Smart Array P410i in Slot 0 (Embedded) (sn: 500143800891C3B0) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (136.7 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 2 (1.4 TB, RAID 5, Recovering, 9% complete) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, Predictive Failure) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, Rebuilding) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK) physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, OK) physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 500143800891C3BF) Să sperăm că nu crapă celelalte acum :D Mulțumesc de ajutor! On Fri, Aug 17, 2018 at 1:09 PM Petru Rațiu <rpe...@gmail.com> wrote: > On Fri, Aug 17, 2018 at 12:34 PM Alex 'CAVE' Cernat <c...@cernat.ro> > wrote: > > > On 17-Aug-18 11:18 AM, Adrian Popa wrote: > > > logicaldrive 2 (1.4 TB, RAID 5, Interim Recovery Mode) > > > > > > physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, > Predictive > > > Failure) > > > physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK) > > > physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, Failed) > > > physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK) > > > physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, OK) > > > physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK) > > > > > ai mare grija ca si discul din portul 3 e pe moarte, oare de asta sa nu > > porneasca rebuildul ? totusi e un non-sense > > > > Eu mai avusesem probleme similare cu raiduri hw cu discuri busite si tin > minte ca a trebuit sa-i dau $ceva ca sa se prinda ca am schimbat discul si > sa-l reinitializeze; speram ca se gaseste cineva care stie mai bine > detaliile ca mine :) > > -- > P. > _______________________________________________ > RLUG mailing list > RLUG@lists.lug.ro > http://lists.lug.ro/mailman/listinfo/rlug_lists.lug.ro > _______________________________________________ RLUG mailing list RLUG@lists.lug.ro http://lists.lug.ro/mailman/listinfo/rlug_lists.lug.ro