Hi,

I tried to use the JK2 graceful shutdown feature through runtime reconfig but my setup failed to work. Anyone has a working example?

My setup has Apache 2.0.47 and 2 instances of Tomcat 4.1.24 on Solaris 8. JK2 connector was used to load balance between the 2 Tomcat servers through socket channel. This setup worked fine with load balancing and sticky session.

Then I tried to set graceful=1 and version=1 in one of the channel inside the worker2.properties file. By reloading the jkstatus page, the ver attribute on the page was incremented. However at this point, I'm not sure whether the runtime reconfiguration is effective or not because when I tried to send new request to the Apache 2 server, the new request was still sending to the Tomcat server where graceful=1 was set in that channel. Also there was no indication of graceful=1 and version=1 being picked up other than ver attribute was updated on the status page. The runtime reconfig and/or graceful shutdown seemed not working in my setup.

Anybody knows what else I can try or has experience setting up JK2 runtime reconfig and graceful shutdown successfully?

Thanks,
ct



---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]
For additional commands, e-mail: [EMAIL PROTECTED]