[Touch-packages] [Bug 1741045] Re: Change the default resample-method to speex-float-N (N > 1) in daemon.conf
I changed the resample-method to soxr-hq, and I'll be testing it for some time. According to the manpage of pulse-daemon.conf "the Soxr resamplers generally offer better quality at less CPU compared to other resamplers, such as speex". So far I think it gives better sound quality than speex-float-1 and auto. -- You received this bug notification because you are a member of Ubuntu Touch seeded packages, which is subscribed to pulseaudio in Ubuntu. https://bugs.launchpad.net/bugs/1741045 Title: Change the default resample-method to speex-float-N (N > 1) in daemon.conf Status in PulseAudio: Fix Released Status in pulseaudio package in Ubuntu: Incomplete Bug description: I suggest changing the default resample-method to speex-float-10, instead of speex-float-1, which is the current default now, in /etc/pulse/daemon.conf. It would look like this in daemon.conf: resample-method = speex-float-10 I have always done that since at least 12.04 LTS. I was not satisfied with the sound quality in Ubuntu compared to Windows, so I changed the resample-method. In my day-to-day usage, it gives better sound quality without sacrificing CPU power. I have not tried other resample methods. Maybe there are better options I don't know about. ProblemType: Bug DistroRelease: Ubuntu 17.10 Package: pulseaudio 1:10.0-2ubuntu3 ProcVersionSignature: Ubuntu 4.13.0-19.22-generic 4.13.13 Uname: Linux 4.13.0-19-generic x86_64 ApportVersion: 2.20.7-0ubuntu3.6 Architecture: amd64 AudioDevicesInUse: USERPID ACCESS COMMAND /dev/snd/controlC0: amr1696 F pulseaudio CurrentDesktop: ubuntu:GNOME Date: Wed Jan 3 14:37:25 2018 InstallationDate: Installed on 2017-10-02 (92 days ago) InstallationMedia: Ubuntu 17.10 "Artful Aardvark" - Beta amd64 (20170930) SourcePackage: pulseaudio UpgradeStatus: No upgrade log present (probably fresh install) dmi.bios.date: 04/08/2011 dmi.bios.vendor: Award Software International, Inc. dmi.bios.version: F2 dmi.board.name: GA-78LMT-S2P dmi.board.vendor: Gigabyte Technology Co., Ltd. dmi.chassis.type: 3 dmi.chassis.vendor: Gigabyte Technology Co., Ltd. dmi.modalias: dmi:bvnAwardSoftwareInternational,Inc.:bvrF2:bd04/08/2011:svnGigabyteTechnologyCo.,Ltd.:pnGA-78LMT-S2P:pvr:rvnGigabyteTechnologyCo.,Ltd.:rnGA-78LMT-S2P:rvr:cvnGigabyteTechnologyCo.,Ltd.:ct3:cvr: dmi.product.name: GA-78LMT-S2P dmi.sys.vendor: Gigabyte Technology Co., Ltd. modified.conffile..etc.pulse.daemon.conf: [modified] mtime.conffile..etc.pulse.daemon.conf: 2017-10-05T12:39:48.718018 To manage notifications about this bug go to: https://bugs.launchpad.net/pulseaudio/+bug/1741045/+subscriptions -- Mailing list: https://launchpad.net/~touch-packages Post to : touch-packages@lists.launchpad.net Unsubscribe : https://launchpad.net/~touch-packages More help : https://help.launchpad.net/ListHelp
[Touch-packages] [Bug 1741045] Re: Change the default resample-method to speex-float-N (N > 1) in daemon.conf
unsure, you are the one who reported an issue/request for change, do you think you request has been addressed or do you still think changing would be better? -- You received this bug notification because you are a member of Ubuntu Touch seeded packages, which is subscribed to pulseaudio in Ubuntu. https://bugs.launchpad.net/bugs/1741045 Title: Change the default resample-method to speex-float-N (N > 1) in daemon.conf Status in PulseAudio: Fix Released Status in pulseaudio package in Ubuntu: Incomplete Bug description: I suggest changing the default resample-method to speex-float-10, instead of speex-float-1, which is the current default now, in /etc/pulse/daemon.conf. It would look like this in daemon.conf: resample-method = speex-float-10 I have always done that since at least 12.04 LTS. I was not satisfied with the sound quality in Ubuntu compared to Windows, so I changed the resample-method. In my day-to-day usage, it gives better sound quality without sacrificing CPU power. I have not tried other resample methods. Maybe there are better options I don't know about. ProblemType: Bug DistroRelease: Ubuntu 17.10 Package: pulseaudio 1:10.0-2ubuntu3 ProcVersionSignature: Ubuntu 4.13.0-19.22-generic 4.13.13 Uname: Linux 4.13.0-19-generic x86_64 ApportVersion: 2.20.7-0ubuntu3.6 Architecture: amd64 AudioDevicesInUse: USERPID ACCESS COMMAND /dev/snd/controlC0: amr1696 F pulseaudio CurrentDesktop: ubuntu:GNOME Date: Wed Jan 3 14:37:25 2018 InstallationDate: Installed on 2017-10-02 (92 days ago) InstallationMedia: Ubuntu 17.10 "Artful Aardvark" - Beta amd64 (20170930) SourcePackage: pulseaudio UpgradeStatus: No upgrade log present (probably fresh install) dmi.bios.date: 04/08/2011 dmi.bios.vendor: Award Software International, Inc. dmi.bios.version: F2 dmi.board.name: GA-78LMT-S2P dmi.board.vendor: Gigabyte Technology Co., Ltd. dmi.chassis.type: 3 dmi.chassis.vendor: Gigabyte Technology Co., Ltd. dmi.modalias: dmi:bvnAwardSoftwareInternational,Inc.:bvrF2:bd04/08/2011:svnGigabyteTechnologyCo.,Ltd.:pnGA-78LMT-S2P:pvr:rvnGigabyteTechnologyCo.,Ltd.:rnGA-78LMT-S2P:rvr:cvnGigabyteTechnologyCo.,Ltd.:ct3:cvr: dmi.product.name: GA-78LMT-S2P dmi.sys.vendor: Gigabyte Technology Co., Ltd. modified.conffile..etc.pulse.daemon.conf: [modified] mtime.conffile..etc.pulse.daemon.conf: 2017-10-05T12:39:48.718018 To manage notifications about this bug go to: https://bugs.launchpad.net/pulseaudio/+bug/1741045/+subscriptions -- Mailing list: https://launchpad.net/~touch-packages Post to : touch-packages@lists.launchpad.net Unsubscribe : https://launchpad.net/~touch-packages More help : https://help.launchpad.net/ListHelp
[Touch-packages] [Bug 1741045] Re: Change the default resample-method to speex-float-N (N > 1) in daemon.conf
I had already changed the resample-method to soxr-mq, and am satisfied with the result. I don't know how to judge which is better, auto or soxr-mq? -- You received this bug notification because you are a member of Ubuntu Touch seeded packages, which is subscribed to pulseaudio in Ubuntu. https://bugs.launchpad.net/bugs/1741045 Title: Change the default resample-method to speex-float-N (N > 1) in daemon.conf Status in PulseAudio: Fix Released Status in pulseaudio package in Ubuntu: Incomplete Bug description: I suggest changing the default resample-method to speex-float-10, instead of speex-float-1, which is the current default now, in /etc/pulse/daemon.conf. It would look like this in daemon.conf: resample-method = speex-float-10 I have always done that since at least 12.04 LTS. I was not satisfied with the sound quality in Ubuntu compared to Windows, so I changed the resample-method. In my day-to-day usage, it gives better sound quality without sacrificing CPU power. I have not tried other resample methods. Maybe there are better options I don't know about. ProblemType: Bug DistroRelease: Ubuntu 17.10 Package: pulseaudio 1:10.0-2ubuntu3 ProcVersionSignature: Ubuntu 4.13.0-19.22-generic 4.13.13 Uname: Linux 4.13.0-19-generic x86_64 ApportVersion: 2.20.7-0ubuntu3.6 Architecture: amd64 AudioDevicesInUse: USERPID ACCESS COMMAND /dev/snd/controlC0: amr1696 F pulseaudio CurrentDesktop: ubuntu:GNOME Date: Wed Jan 3 14:37:25 2018 InstallationDate: Installed on 2017-10-02 (92 days ago) InstallationMedia: Ubuntu 17.10 "Artful Aardvark" - Beta amd64 (20170930) SourcePackage: pulseaudio UpgradeStatus: No upgrade log present (probably fresh install) dmi.bios.date: 04/08/2011 dmi.bios.vendor: Award Software International, Inc. dmi.bios.version: F2 dmi.board.name: GA-78LMT-S2P dmi.board.vendor: Gigabyte Technology Co., Ltd. dmi.chassis.type: 3 dmi.chassis.vendor: Gigabyte Technology Co., Ltd. dmi.modalias: dmi:bvnAwardSoftwareInternational,Inc.:bvrF2:bd04/08/2011:svnGigabyteTechnologyCo.,Ltd.:pnGA-78LMT-S2P:pvr:rvnGigabyteTechnologyCo.,Ltd.:rnGA-78LMT-S2P:rvr:cvnGigabyteTechnologyCo.,Ltd.:ct3:cvr: dmi.product.name: GA-78LMT-S2P dmi.sys.vendor: Gigabyte Technology Co., Ltd. modified.conffile..etc.pulse.daemon.conf: [modified] mtime.conffile..etc.pulse.daemon.conf: 2017-10-05T12:39:48.718018 To manage notifications about this bug go to: https://bugs.launchpad.net/pulseaudio/+bug/1741045/+subscriptions -- Mailing list: https://launchpad.net/~touch-packages Post to : touch-packages@lists.launchpad.net Unsubscribe : https://launchpad.net/~touch-packages More help : https://help.launchpad.net/ListHelp
[Touch-packages] [Bug 1741045] Re: Change the default resample-method to speex-float-N (N > 1) in daemon.conf
Well, how are you supposed to know, which resample method is actually used? -- You received this bug notification because you are a member of Ubuntu Touch seeded packages, which is subscribed to pulseaudio in Ubuntu. https://bugs.launchpad.net/bugs/1741045 Title: Change the default resample-method to speex-float-N (N > 1) in daemon.conf Status in PulseAudio: Fix Released Status in pulseaudio package in Ubuntu: Incomplete Bug description: I suggest changing the default resample-method to speex-float-10, instead of speex-float-1, which is the current default now, in /etc/pulse/daemon.conf. It would look like this in daemon.conf: resample-method = speex-float-10 I have always done that since at least 12.04 LTS. I was not satisfied with the sound quality in Ubuntu compared to Windows, so I changed the resample-method. In my day-to-day usage, it gives better sound quality without sacrificing CPU power. I have not tried other resample methods. Maybe there are better options I don't know about. ProblemType: Bug DistroRelease: Ubuntu 17.10 Package: pulseaudio 1:10.0-2ubuntu3 ProcVersionSignature: Ubuntu 4.13.0-19.22-generic 4.13.13 Uname: Linux 4.13.0-19-generic x86_64 ApportVersion: 2.20.7-0ubuntu3.6 Architecture: amd64 AudioDevicesInUse: USERPID ACCESS COMMAND /dev/snd/controlC0: amr1696 F pulseaudio CurrentDesktop: ubuntu:GNOME Date: Wed Jan 3 14:37:25 2018 InstallationDate: Installed on 2017-10-02 (92 days ago) InstallationMedia: Ubuntu 17.10 "Artful Aardvark" - Beta amd64 (20170930) SourcePackage: pulseaudio UpgradeStatus: No upgrade log present (probably fresh install) dmi.bios.date: 04/08/2011 dmi.bios.vendor: Award Software International, Inc. dmi.bios.version: F2 dmi.board.name: GA-78LMT-S2P dmi.board.vendor: Gigabyte Technology Co., Ltd. dmi.chassis.type: 3 dmi.chassis.vendor: Gigabyte Technology Co., Ltd. dmi.modalias: dmi:bvnAwardSoftwareInternational,Inc.:bvrF2:bd04/08/2011:svnGigabyteTechnologyCo.,Ltd.:pnGA-78LMT-S2P:pvr:rvnGigabyteTechnologyCo.,Ltd.:rnGA-78LMT-S2P:rvr:cvnGigabyteTechnologyCo.,Ltd.:ct3:cvr: dmi.product.name: GA-78LMT-S2P dmi.sys.vendor: Gigabyte Technology Co., Ltd. modified.conffile..etc.pulse.daemon.conf: [modified] mtime.conffile..etc.pulse.daemon.conf: 2017-10-05T12:39:48.718018 To manage notifications about this bug go to: https://bugs.launchpad.net/pulseaudio/+bug/1741045/+subscriptions -- Mailing list: https://launchpad.net/~touch-packages Post to : touch-packages@lists.launchpad.net Unsubscribe : https://launchpad.net/~touch-packages More help : https://help.launchpad.net/ListHelp
[Touch-packages] [Bug 1741045] Re: Change the default resample-method to speex-float-N (N > 1) in daemon.conf
Upstream bug comment 'Now there is resample-method setting "auto" which seems to be the default.' Is the problem still existing on recent Ubuntu versions with the auto value? ** Changed in: pulseaudio (Ubuntu) Status: New => Incomplete -- You received this bug notification because you are a member of Ubuntu Touch seeded packages, which is subscribed to pulseaudio in Ubuntu. https://bugs.launchpad.net/bugs/1741045 Title: Change the default resample-method to speex-float-N (N > 1) in daemon.conf Status in PulseAudio: Fix Released Status in pulseaudio package in Ubuntu: Incomplete Bug description: I suggest changing the default resample-method to speex-float-10, instead of speex-float-1, which is the current default now, in /etc/pulse/daemon.conf. It would look like this in daemon.conf: resample-method = speex-float-10 I have always done that since at least 12.04 LTS. I was not satisfied with the sound quality in Ubuntu compared to Windows, so I changed the resample-method. In my day-to-day usage, it gives better sound quality without sacrificing CPU power. I have not tried other resample methods. Maybe there are better options I don't know about. ProblemType: Bug DistroRelease: Ubuntu 17.10 Package: pulseaudio 1:10.0-2ubuntu3 ProcVersionSignature: Ubuntu 4.13.0-19.22-generic 4.13.13 Uname: Linux 4.13.0-19-generic x86_64 ApportVersion: 2.20.7-0ubuntu3.6 Architecture: amd64 AudioDevicesInUse: USERPID ACCESS COMMAND /dev/snd/controlC0: amr1696 F pulseaudio CurrentDesktop: ubuntu:GNOME Date: Wed Jan 3 14:37:25 2018 InstallationDate: Installed on 2017-10-02 (92 days ago) InstallationMedia: Ubuntu 17.10 "Artful Aardvark" - Beta amd64 (20170930) SourcePackage: pulseaudio UpgradeStatus: No upgrade log present (probably fresh install) dmi.bios.date: 04/08/2011 dmi.bios.vendor: Award Software International, Inc. dmi.bios.version: F2 dmi.board.name: GA-78LMT-S2P dmi.board.vendor: Gigabyte Technology Co., Ltd. dmi.chassis.type: 3 dmi.chassis.vendor: Gigabyte Technology Co., Ltd. dmi.modalias: dmi:bvnAwardSoftwareInternational,Inc.:bvrF2:bd04/08/2011:svnGigabyteTechnologyCo.,Ltd.:pnGA-78LMT-S2P:pvr:rvnGigabyteTechnologyCo.,Ltd.:rnGA-78LMT-S2P:rvr:cvnGigabyteTechnologyCo.,Ltd.:ct3:cvr: dmi.product.name: GA-78LMT-S2P dmi.sys.vendor: Gigabyte Technology Co., Ltd. modified.conffile..etc.pulse.daemon.conf: [modified] mtime.conffile..etc.pulse.daemon.conf: 2017-10-05T12:39:48.718018 To manage notifications about this bug go to: https://bugs.launchpad.net/pulseaudio/+bug/1741045/+subscriptions -- Mailing list: https://launchpad.net/~touch-packages Post to : touch-packages@lists.launchpad.net Unsubscribe : https://launchpad.net/~touch-packages More help : https://help.launchpad.net/ListHelp
[Touch-packages] [Bug 1741045] Re: Change the default resample-method to speex-float-N (N > 1) in daemon.conf
** Changed in: pulseaudio Status: Unknown => Fix Released ** Changed in: pulseaudio Importance: Wishlist => Unknown -- You received this bug notification because you are a member of Ubuntu Touch seeded packages, which is subscribed to pulseaudio in Ubuntu. https://bugs.launchpad.net/bugs/1741045 Title: Change the default resample-method to speex-float-N (N > 1) in daemon.conf Status in PulseAudio: Fix Released Status in pulseaudio package in Ubuntu: New Bug description: I suggest changing the default resample-method to speex-float-10, instead of speex-float-1, which is the current default now, in /etc/pulse/daemon.conf. It would look like this in daemon.conf: resample-method = speex-float-10 I have always done that since at least 12.04 LTS. I was not satisfied with the sound quality in Ubuntu compared to Windows, so I changed the resample-method. In my day-to-day usage, it gives better sound quality without sacrificing CPU power. I have not tried other resample methods. Maybe there are better options I don't know about. ProblemType: Bug DistroRelease: Ubuntu 17.10 Package: pulseaudio 1:10.0-2ubuntu3 ProcVersionSignature: Ubuntu 4.13.0-19.22-generic 4.13.13 Uname: Linux 4.13.0-19-generic x86_64 ApportVersion: 2.20.7-0ubuntu3.6 Architecture: amd64 AudioDevicesInUse: USERPID ACCESS COMMAND /dev/snd/controlC0: amr1696 F pulseaudio CurrentDesktop: ubuntu:GNOME Date: Wed Jan 3 14:37:25 2018 InstallationDate: Installed on 2017-10-02 (92 days ago) InstallationMedia: Ubuntu 17.10 "Artful Aardvark" - Beta amd64 (20170930) SourcePackage: pulseaudio UpgradeStatus: No upgrade log present (probably fresh install) dmi.bios.date: 04/08/2011 dmi.bios.vendor: Award Software International, Inc. dmi.bios.version: F2 dmi.board.name: GA-78LMT-S2P dmi.board.vendor: Gigabyte Technology Co., Ltd. dmi.chassis.type: 3 dmi.chassis.vendor: Gigabyte Technology Co., Ltd. dmi.modalias: dmi:bvnAwardSoftwareInternational,Inc.:bvrF2:bd04/08/2011:svnGigabyteTechnologyCo.,Ltd.:pnGA-78LMT-S2P:pvr:rvnGigabyteTechnologyCo.,Ltd.:rnGA-78LMT-S2P:rvr:cvnGigabyteTechnologyCo.,Ltd.:ct3:cvr: dmi.product.name: GA-78LMT-S2P dmi.sys.vendor: Gigabyte Technology Co., Ltd. modified.conffile..etc.pulse.daemon.conf: [modified] mtime.conffile..etc.pulse.daemon.conf: 2017-10-05T12:39:48.718018 To manage notifications about this bug go to: https://bugs.launchpad.net/pulseaudio/+bug/1741045/+subscriptions -- Mailing list: https://launchpad.net/~touch-packages Post to : touch-packages@lists.launchpad.net Unsubscribe : https://launchpad.net/~touch-packages More help : https://help.launchpad.net/ListHelp
[Touch-packages] [Bug 1741045] Re: Change the default resample-method to speex-float-N (N > 1) in daemon.conf
Launchpad has imported 2 comments from the remote bug at https://bugs.freedesktop.org/show_bug.cgi?id=104486. If you reply to an imported comment from within Launchpad, your comment will be sent to the remote bug automatically. Read more about Launchpad's inter-bugtracker facilities at https://help.launchpad.net/InterBugTracking. On 2018-01-04T07:49:20+00:00 Amr Ibrahim wrote: I suggest changing the default resample-method to speex-float-10, instead of speex-float-1, which is the current default now, in /etc/pulse/daemon.conf. In my day-to-day usage, it gives better sound quality without sacrificing CPU power. I have always done that since at least 2012. I was not satisfied with the sound quality in Ubuntu compared to Windows, so I changed the resample-method. It would look like this in daemon.conf: resample-method = speex-float-10 I have not tried other resample methods. Maybe there are better options I don't know about. Reply at: https://bugs.launchpad.net/ubuntu/+source/pulseaudio/+bug/1741045/comments/3 On 2018-07-30T10:16:36+00:00 Gitlab-migration wrote: -- GitLab Migration Automatic Message -- This bug has been migrated to freedesktop.org's GitLab instance and has been closed from further activity. You can subscribe and participate further through the new bug through this link to our GitLab instance: https://gitlab.freedesktop.org/pulseaudio/pulseaudio/issues/310. Reply at: https://bugs.launchpad.net/ubuntu/+source/pulseaudio/+bug/1741045/comments/6 ** Changed in: pulseaudio Status: Confirmed => Unknown -- You received this bug notification because you are a member of Ubuntu Touch seeded packages, which is subscribed to pulseaudio in Ubuntu. https://bugs.launchpad.net/bugs/1741045 Title: Change the default resample-method to speex-float-N (N > 1) in daemon.conf Status in PulseAudio: Unknown Status in pulseaudio package in Ubuntu: New Bug description: I suggest changing the default resample-method to speex-float-10, instead of speex-float-1, which is the current default now, in /etc/pulse/daemon.conf. It would look like this in daemon.conf: resample-method = speex-float-10 I have always done that since at least 12.04 LTS. I was not satisfied with the sound quality in Ubuntu compared to Windows, so I changed the resample-method. In my day-to-day usage, it gives better sound quality without sacrificing CPU power. I have not tried other resample methods. Maybe there are better options I don't know about. ProblemType: Bug DistroRelease: Ubuntu 17.10 Package: pulseaudio 1:10.0-2ubuntu3 ProcVersionSignature: Ubuntu 4.13.0-19.22-generic 4.13.13 Uname: Linux 4.13.0-19-generic x86_64 ApportVersion: 2.20.7-0ubuntu3.6 Architecture: amd64 AudioDevicesInUse: USERPID ACCESS COMMAND /dev/snd/controlC0: amr1696 F pulseaudio CurrentDesktop: ubuntu:GNOME Date: Wed Jan 3 14:37:25 2018 InstallationDate: Installed on 2017-10-02 (92 days ago) InstallationMedia: Ubuntu 17.10 "Artful Aardvark" - Beta amd64 (20170930) SourcePackage: pulseaudio UpgradeStatus: No upgrade log present (probably fresh install) dmi.bios.date: 04/08/2011 dmi.bios.vendor: Award Software International, Inc. dmi.bios.version: F2 dmi.board.name: GA-78LMT-S2P dmi.board.vendor: Gigabyte Technology Co., Ltd. dmi.chassis.type: 3 dmi.chassis.vendor: Gigabyte Technology Co., Ltd. dmi.modalias: dmi:bvnAwardSoftwareInternational,Inc.:bvrF2:bd04/08/2011:svnGigabyteTechnologyCo.,Ltd.:pnGA-78LMT-S2P:pvr:rvnGigabyteTechnologyCo.,Ltd.:rnGA-78LMT-S2P:rvr:cvnGigabyteTechnologyCo.,Ltd.:ct3:cvr: dmi.product.name: GA-78LMT-S2P dmi.sys.vendor: Gigabyte Technology Co., Ltd. modified.conffile..etc.pulse.daemon.conf: [modified] mtime.conffile..etc.pulse.daemon.conf: 2017-10-05T12:39:48.718018 To manage notifications about this bug go to: https://bugs.launchpad.net/pulseaudio/+bug/1741045/+subscriptions -- Mailing list: https://launchpad.net/~touch-packages Post to : touch-packages@lists.launchpad.net Unsubscribe : https://launchpad.net/~touch-packages More help : https://help.launchpad.net/ListHelp