User can get correct HCLK frequency during driver probe stage
by adding the following configuration in the device tree.
"clocks = <&scu ASPEED_CLK_AHB>".

Signed-off-by: Chin-Ting Kuo <chin-ting_...@aspeedtech.com>
---
 drivers/clk/aspeed/clk_ast2500.c | 24 ++++++++++++++++++++++++
 1 file changed, 24 insertions(+)

diff --git a/drivers/clk/aspeed/clk_ast2500.c b/drivers/clk/aspeed/clk_ast2500.c
index a1b4496ca2..d2a58a8462 100644
--- a/drivers/clk/aspeed/clk_ast2500.c
+++ b/drivers/clk/aspeed/clk_ast2500.c
@@ -29,6 +29,12 @@
 
 #define D2PLL_DEFAULT_RATE     (250 * 1000 * 1000)
 
+/*
+ * AXI/AHB clock selection, taken from Aspeed SDK
+ */
+#define SCU_HWSTRAP_AXIAHB_DIV_SHIFT    9
+#define SCU_HWSTRAP_AXIAHB_DIV_MASK     (0x7 << SCU_HWSTRAP_AXIAHB_DIV_SHIFT)
+
 DECLARE_GLOBAL_DATA_PTR;
 
 /*
@@ -85,6 +91,21 @@ static ulong ast2500_get_clkin(struct ast2500_scu *scu)
                        ? 25 * 1000 * 1000 : 24 * 1000 * 1000;
 }
 
+static u32 ast2500_get_hclk(struct ast2500_scu *scu)
+{
+       ulong clkin = ast2500_get_clkin(scu);
+       u32 hpll_reg = readl(&scu->h_pll_param);
+       ulong axi_div = 2;
+       u32 rate;
+       ulong ahb_div = 1 + ((readl(&scu->hwstrap)
+                             & SCU_HWSTRAP_AXIAHB_DIV_MASK)
+                            >> SCU_HWSTRAP_AXIAHB_DIV_SHIFT);
+
+       rate = ast2500_get_hpll_rate(clkin, hpll_reg);
+
+       return (rate / axi_div / ahb_div);
+}
+
 /**
  * Get current rate or uart clock
  *
@@ -146,6 +167,9 @@ static ulong ast2500_clk_get_rate(struct clk *clk)
                        rate = rate / apb_div;
                }
                break;
+       case ASPEED_CLK_AHB:
+               rate = ast2500_get_hclk(priv->scu);
+               break;
        case ASPEED_CLK_SDIO:
                {
                        ulong apb_div = 4 + 4 * ((readl(&priv->scu->clk_sel1)
-- 
2.25.1