On 24.05.21 04:22, meng...@windriver.com wrote:
From: MengLi
In uboot command line environment, watchdog is not able to be
stopped with below commands:
SOCFPGA_STRATIX10 # wdt dev watchdog@ffd00200
SOCFPGA_STRATIX10 # wdt stop
Refer to watchdog driver in linux kernel, it is also need to reset
watchdog after disable it so that the disable action takes effect.
Signed-off-by: Meng Li
Reviewed-by: Stefan Roese
Applied to u-boot-marvell/master
Thanks,
Stefan
---
v5:
fix build issue, and verify this patch with latest upstream u-boot.
v4:
Remove the unauthorized signature.
v3:
Add the resets to designware_wdt_priv and initialize it in probe().
v2:
Change "#if CONFIG_IS_ENABLED(DM_RESET)" into
"if (CONFIG_IS_ENABLED(DM_RESET)) {", and define the variable
into if condition sentence.
---
drivers/watchdog/designware_wdt.c | 19 +++
1 file changed, 15 insertions(+), 4 deletions(-)
diff --git a/drivers/watchdog/designware_wdt.c
b/drivers/watchdog/designware_wdt.c
index 9e5487168c..afed81e6c6 100644
--- a/drivers/watchdog/designware_wdt.c
+++ b/drivers/watchdog/designware_wdt.c
@@ -22,6 +22,7 @@
struct designware_wdt_priv {
void __iomem*base;
unsigned intclk_khz;
+ struct reset_ctl_bulk *resets;
};
/*
@@ -95,6 +96,18 @@ static int designware_wdt_stop(struct udevice *dev)
designware_wdt_reset(dev);
writel(0, priv->base + DW_WDT_CR);
+if (CONFIG_IS_ENABLED(DM_RESET)) {
+ int ret;
+
+ ret = reset_assert_bulk(priv->resets);
+ if (ret)
+ return ret;
+
+ ret = reset_deassert_bulk(priv->resets);
+ if (ret)
+ return ret;
+ }
+
return 0;
}
@@ -143,13 +156,11 @@ static int designware_wdt_probe(struct udevice *dev)
#endif
if (CONFIG_IS_ENABLED(DM_RESET)) {
- struct reset_ctl_bulk resets;
-
- ret = reset_get_bulk(dev, );
+ ret = reset_get_bulk(dev, priv->resets);
if (ret)
goto err;
- ret = reset_deassert_bulk();
+ ret = reset_deassert_bulk(priv->resets);
if (ret)
goto err;
}
Viele Grüße,