RE: [U2] Formatting Data Update

2005-08-26 Thread Martin Canty
Hi Al,

Certainly, you can use the $BASICTYPE compiler directive to assert a
BASICTYPE U within your compilation, it's documented at
http://publibfi.boulder.ibm.com/epubs/pdf/9163.pdf...

Martin

 

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Al DeWitt
Sent: Friday, August 26, 2005 3:13 PM
To: u2-users@listserver.u2ug.org
Subject: [U2] Formatting Data Update

Thanks to all your help I was able to finally get it working.

However, it did mean that I had to compile as a BASICTYPE U and not as
a BASICTYPE P.  I did this by writing a little paragraph that does the
following:

PA
BASICTYPE U
BASIC BP EPCS9010.4
CATALOG BP EPCS9010.4 DIRECT FORCE
BASICTYPE P


I have to do this in every account I move this program to because our
software (Avanti) runs as BASICTYPE P.

My question: Is there something I can put in the source code of my
program that tells it to compile as a BASICTYPE U so that when I do:

OS.ED BP EPCS9010.4
  FIBCDF

It compiles as BASICTYPE U?  

I'm concerned that when I need to recompile all the BP entries in mass
using a select list this program will compile back to the default
BASICTYPE P and it stops working.

Thanks.

Al
---
u2-users mailing list
u2-users@listserver.u2ug.org
To unsubscribe please visit http://listserver.u2ug.org/
---
u2-users mailing list
u2-users@listserver.u2ug.org
To unsubscribe please visit http://listserver.u2ug.org/


RE: [U2] Formatting Data Update

2005-08-26 Thread Larry Hiscock
$BASICTYPE U at the top of the program should do the trick (HELP
$BASICTYPE)

Larry Hiscock
Western Computer Services
 

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Al DeWitt
Sent: Friday, August 26, 2005 3:13 PM
To: u2-users@listserver.u2ug.org
Subject: [U2] Formatting Data Update

Thanks to all your help I was able to finally get it working.

However, it did mean that I had to compile as a BASICTYPE U and not as a
BASICTYPE P.  I did this by writing a little paragraph that does the
following:

PA
BASICTYPE U
BASIC BP EPCS9010.4
CATALOG BP EPCS9010.4 DIRECT FORCE
BASICTYPE P


I have to do this in every account I move this program to because our
software (Avanti) runs as BASICTYPE P.

My question: Is there something I can put in the source code of my program
that tells it to compile as a BASICTYPE U so that when I do:

OS.ED BP EPCS9010.4
  FIBCDF

It compiles as BASICTYPE U?  

I'm concerned that when I need to recompile all the BP entries in mass using
a select list this program will compile back to the default BASICTYPE P
and it stops working.

Thanks.

Al
---