Re: [Ubnt_users] Rocket M5 vs Rocket M5 AC Lite

2014-10-24 Thread Elton Wilson
We have the 10 mile link on 50mhz now, but it was fine on 40mhz for a
month. Our other link is on 1.5 miles and its on 40mhz.

On Mon, Oct 13, 2014 at 6:23 PM, Scott Lambert lamb...@lambertfam.org
wrote:

 On Mon, Oct 13, 2014 at 04:44:06PM -1000, Elton Wilson wrote:
  We have a 10mile link that sees about 150mb download at peak time. Its
 been
  running solid for over 2 months. We had an Airfiber link there that was
  doing well, but because we may loose power to one side we decided to try
  the RocketAC since it uses a lot less power (watts).

 What channel width?  40MHz?

  6 weeks ago we swapped out an RM5 link (well one side was a Power Bridge)
  with 2 rocket ACs. That link sees almost 120mb peak time. Haven't had one
  issue out of it either. I just received 4 Nanobridge ACs but we haven't
  deployed any yet.

 Channel width?  40MHz?

 --
 Scott LambertKC5MLE   Unix SysAdmin
 lamb...@lambertfam.org
 ___
 Ubnt_users mailing list
 Ubnt_users@wispa.org
 http://lists.wispa.org/mailman/listinfo/ubnt_users

___
Ubnt_users mailing list
Ubnt_users@wispa.org
http://lists.wispa.org/mailman/listinfo/ubnt_users


Re: [Ubnt_users] Rackmount 48V inverters for Ubiquiti POPs

2014-10-24 Thread Josh Reynolds
I've been looking for the same thing - something that can do per-port 
for 24/48 volt. southern_drawl Can't find a dang thing. /southern_drawl


Josh Reynolds, Chief Information Officer
SPITwSPOTS, www.spitwspots.com http://www.spitwspots.com

On 10/24/2014 02:07 PM, Andris Bjornson wrote:
I've been doing DIN rail style small NEMA enclosures at POPs for a 
while now using Packetflux, Mikrotik and other similar equipment, but 
now I find myself needing to figure out a similar setup for a 
rackmount installation.  My input voltage is -48VDC at a telco 
colocation site.


I like the gigabit speeds and per-port control of 24V / 48V PoE 
voltages on the EdgeSwitch and the Netonix switches - but those of 
course want AC input.


Seems like the straightforward option may be to find a 1U Rackmount, 
48V inverter.  Any good brands / suggestions?  Would ideally be 
ethernet manageable.  I'm seeing a lot of high wattage (1000W+) models 
(Cotek and UniPower) and would like to find something smaller / less 
expensive.


Open to alternate suggestions too, definitely need rackmount and 
trying to minimize the number of rack U required.


Thanks!
ᐧ


___
Ubnt_users mailing list
Ubnt_users@wispa.org
http://lists.wispa.org/mailman/listinfo/ubnt_users