Re: Re: failed when job graph change

2024-01-24 Thread nick toker
Hi
i adding a new sink that was not exists in the graph
1. stop with save point
2. run the the new graph with the new sink operator ( from save point)

in this case the job stuck in initializing forever because cant complete
transaction ( on the new operator , kafka topic)

i dont understand how change the uid will help its a new operator with new
uid

nick

‫בתאריך יום ד׳, 24 בינו׳ 2024 ב-19:30 מאת ‪Feng Jin‬‏ <‪
jinfeng1...@gmail.com‬‏>:‬

> Hi nick
>
> If you want to modify the sink operator , I think you can modify the uid
> of the operator to avoid restoring the state that does not belong to it.
>
>
> Best,
> Feng
>
>
> On Thu, Jan 25, 2024 at 1:19 AM nick toker 
> wrote:
>
>> hi
>>
>> i didn't found anything in the log
>> but i found that it happened when i add a new sink operator
>> and because i work with checkpoints  the flink can't finish the
>> transaction ( the new topic in kafka not part of the transaction before i
>> added the new sink operator)
>>
>> so i must cancel the job to make it work
>>
>> How can I solve this issue?
>>
>>
>> nick
>>
>> ‫בתאריך יום ב׳, 4 בדצמ׳ 2023 ב-10:27 מאת ‪Xuyang‬‏ <‪xyzhong...@163.com
>> ‬‏>:‬
>>
>>> Hi,
>>> Can you attach the log about the exception when job failed?
>>>
>>> --
>>> Best!
>>> Xuyang
>>>
>>>
>>> 在 2023-12-04 15:56:04,"nick toker"  写道:
>>>
>>> Hi
>>>
>>> restart the job it's ok and i do that , but i must cancel the job and
>>> submit a new one and i dont want the data from the state
>>> forget to  mention that i use the parameter "-allowNonRestoredState"
>>>
>>>
>>> my steps:
>>> 1. stop the job with savepoint
>>> 2. run the updated job ( update job graph) from savepoint
>>>
>>> expect it to run
>>>
>>> currently the result is the the job fail
>>>
>>> nick
>>>
>>>
>>>
>>> ‫בתאריך יום ב׳, 4 בדצמ׳ 2023 ב-8:41 מאת ‪Xuyang‬‏ <‪xyzhong...@163.com
>>> ‬‏>:‬
>>>
 Hi, nick.

 > using savepoint i must cancel the job to be able run the new graph

 Do you mean that you need cancel and start the job using the new flink
 job graph in 1.17.1,
 and in the past, it was able to make the changes to the new operator
 effective without restarting the job?

 I think in order for the new job graph to take effect, it is necessary
 to restart the job.

 --
 Best!
 Xuyang


 At 2023-12-03 21:49:23, "nick toker"  wrote:

 Hi

 when i add or remove an operator in the job graph , using savepoint i
 must cancel the job to be able run the new graph

 e.g. by adding or removing operator (like new sink target)
 it was working in the past
 i using flink 1.17.1

 1. is it a known bug? if so when planned to be fix

 2. do i need to do something to make it work?


 nick




Re: Re: failed when job graph change

2024-01-24 Thread Feng Jin
Hi nick

If you want to modify the sink operator , I think you can modify the uid of
the operator to avoid restoring the state that does not belong to it.


Best,
Feng


On Thu, Jan 25, 2024 at 1:19 AM nick toker  wrote:

> hi
>
> i didn't found anything in the log
> but i found that it happened when i add a new sink operator
> and because i work with checkpoints  the flink can't finish the
> transaction ( the new topic in kafka not part of the transaction before i
> added the new sink operator)
>
> so i must cancel the job to make it work
>
> How can I solve this issue?
>
>
> nick
>
> ‫בתאריך יום ב׳, 4 בדצמ׳ 2023 ב-10:27 מאת ‪Xuyang‬‏ <‪xyzhong...@163.com
> ‬‏>:‬
>
>> Hi,
>> Can you attach the log about the exception when job failed?
>>
>> --
>> Best!
>> Xuyang
>>
>>
>> 在 2023-12-04 15:56:04,"nick toker"  写道:
>>
>> Hi
>>
>> restart the job it's ok and i do that , but i must cancel the job and
>> submit a new one and i dont want the data from the state
>> forget to  mention that i use the parameter "-allowNonRestoredState"
>>
>>
>> my steps:
>> 1. stop the job with savepoint
>> 2. run the updated job ( update job graph) from savepoint
>>
>> expect it to run
>>
>> currently the result is the the job fail
>>
>> nick
>>
>>
>>
>> ‫בתאריך יום ב׳, 4 בדצמ׳ 2023 ב-8:41 מאת ‪Xuyang‬‏ <‪xyzhong...@163.com
>> ‬‏>:‬
>>
>>> Hi, nick.
>>>
>>> > using savepoint i must cancel the job to be able run the new graph
>>>
>>> Do you mean that you need cancel and start the job using the new flink
>>> job graph in 1.17.1,
>>> and in the past, it was able to make the changes to the new operator
>>> effective without restarting the job?
>>>
>>> I think in order for the new job graph to take effect, it is necessary
>>> to restart the job.
>>>
>>> --
>>> Best!
>>> Xuyang
>>>
>>>
>>> At 2023-12-03 21:49:23, "nick toker"  wrote:
>>>
>>> Hi
>>>
>>> when i add or remove an operator in the job graph , using savepoint i
>>> must cancel the job to be able run the new graph
>>>
>>> e.g. by adding or removing operator (like new sink target)
>>> it was working in the past
>>> i using flink 1.17.1
>>>
>>> 1. is it a known bug? if so when planned to be fix
>>>
>>> 2. do i need to do something to make it work?
>>>
>>>
>>> nick
>>>
>>>


Re: Re: failed when job graph change

2024-01-24 Thread nick toker
hi

i didn't found anything in the log
but i found that it happened when i add a new sink operator
and because i work with checkpoints  the flink can't finish the transaction
( the new topic in kafka not part of the transaction before i added the new
sink operator)

so i must cancel the job to make it work

How can I solve this issue?


nick

‫בתאריך יום ב׳, 4 בדצמ׳ 2023 ב-10:27 מאת ‪Xuyang‬‏ <‪xyzhong...@163.com‬‏>:‬

> Hi,
> Can you attach the log about the exception when job failed?
>
> --
> Best!
> Xuyang
>
>
> 在 2023-12-04 15:56:04,"nick toker"  写道:
>
> Hi
>
> restart the job it's ok and i do that , but i must cancel the job and
> submit a new one and i dont want the data from the state
> forget to  mention that i use the parameter "-allowNonRestoredState"
>
>
> my steps:
> 1. stop the job with savepoint
> 2. run the updated job ( update job graph) from savepoint
>
> expect it to run
>
> currently the result is the the job fail
>
> nick
>
>
>
> ‫בתאריך יום ב׳, 4 בדצמ׳ 2023 ב-8:41 מאת ‪Xuyang‬‏ <‪xyzhong...@163.com
> ‬‏>:‬
>
>> Hi, nick.
>>
>> > using savepoint i must cancel the job to be able run the new graph
>>
>> Do you mean that you need cancel and start the job using the new flink
>> job graph in 1.17.1,
>> and in the past, it was able to make the changes to the new operator
>> effective without restarting the job?
>>
>> I think in order for the new job graph to take effect, it is necessary to
>> restart the job.
>>
>> --
>> Best!
>> Xuyang
>>
>>
>> At 2023-12-03 21:49:23, "nick toker"  wrote:
>>
>> Hi
>>
>> when i add or remove an operator in the job graph , using savepoint i
>> must cancel the job to be able run the new graph
>>
>> e.g. by adding or removing operator (like new sink target)
>> it was working in the past
>> i using flink 1.17.1
>>
>> 1. is it a known bug? if so when planned to be fix
>>
>> 2. do i need to do something to make it work?
>>
>>
>> nick
>>
>>


Re: failed when job graph change

2023-12-03 Thread nick toker
Hi

restart the job it's ok and i do that , but i must cancel the job and
submit a new one and i dont want the data from the state
forget to  mention that i use the parameter "-allowNonRestoredState"


my steps:
1. stop the job with savepoint
2. run the updated job ( update job graph) from savepoint

expect it to run

currently the result is the the job fail

nick



‫בתאריך יום ב׳, 4 בדצמ׳ 2023 ב-8:41 מאת ‪Xuyang‬‏ <‪xyzhong...@163.com‬‏>:‬

> Hi, nick.
>
> > using savepoint i must cancel the job to be able run the new graph
>
> Do you mean that you need cancel and start the job using the new flink job
> graph in 1.17.1,
> and in the past, it was able to make the changes to the new operator
> effective without restarting the job?
>
> I think in order for the new job graph to take effect, it is necessary to
> restart the job.
>
> --
> Best!
> Xuyang
>
>
> At 2023-12-03 21:49:23, "nick toker"  wrote:
>
> Hi
>
> when i add or remove an operator in the job graph , using savepoint i must
> cancel the job to be able run the new graph
>
> e.g. by adding or removing operator (like new sink target)
> it was working in the past
> i using flink 1.17.1
>
> 1. is it a known bug? if so when planned to be fix
>
> 2. do i need to do something to make it work?
>
>
> nick
>
>